RT Journal Article SR Electronic T1 Quantitative Analysis of Myocardial Perfusion SPECT Anatomically Guided by Coregistered 64-Slice Coronary CT Angiography JF Journal of Nuclear Medicine JO J Nucl Med FD Society of Nuclear Medicine SP 1621 OP 1630 DO 10.2967/jnumed.109.063982 VO 50 IS 10 A1 Piotr J. Slomka A1 Victor Y. Cheng A1 Damini Dey A1 Jonghye Woo A1 Amit Ramesh A1 Serge Van Kriekinge A1 Yasuzuki Suzuki A1 Yaron Elad A1 Ronald Karlsberg A1 Daniel S. Berman A1 Guido Germano YR 2009 UL http://jnm.snmjournals.org/content/50/10/1621.abstract AB Sequential testing by coronary CT angiography (CTA) and myocardial perfusion SPECT (MPS) obtained on stand-alone scanners may be needed to diagnose coronary artery disease in equivocal cases. We have developed an automated technique for MPS–CTA registration and demonstrate its utility for improved MPS quantification by guiding the coregistered physiologic (MPS) with anatomic CTA information. Methods: Automated registration of MPS left ventricular (LV) surfaces with CTA coronary trees was accomplished by iterative minimization of voxel differences between presegmented CTA volumes and motion-frozen MPS data. Studies of 35 sequential patients (26 men; mean age, 67 ± 12 y) with 64-slice coronary CTA, MPS, and available results of the invasive coronary angiography performed within 3 mo were retrospectively analyzed. Three-dimensional coronary vessels and CTA slices were extracted and fused with quantitative MPS results mapped on LV surfaces and MPS coronary regions. Automatically coregistered CTA images and extracted trees were used to correct the MPS contours and to adjust the standard vascular region definitions for MPS quantification. Results: Automated coregistration of MPS and coronary CTA had the success rate of 96% as assessed visually; the average errors were 4.3 ± 3.3 mm in translation and 1.5 ± 2.6 degrees in rotation on stress and 4.2 ± 3.1 mm in translation and 1.7 ± 3.2 degrees in rotation on rest. MPS vascular region definition was adjusted in 17 studies, and LV contours were adjusted in 11 studies using coregistered CTA images as a guide. CTA-guided myocardial perfusion analysis, compared with standard MPS analysis, resulted in improved area under the receiver-operating-characteristic (ROC) curves for the detection of right coronary artery (RCA) and left circumflex artery (LCX) lesions (0.84 ± 0.08 vs. 0.70 ± 0.11 for LCX, P = 0.03, and 0.92 ± 0.05 vs. 0.75 ± 0.09 for RCA, P = 0.02). Conclusion: Software image coregistration of stand-alone coronary CTA and MPS obtained on separate scanners can be performed rapidly and automatically, allowing CTA-guided contour and vascular territory adjustment on MPS for improved quantitative MPS analysis.