RT Journal Article SR Electronic T1 Effect of Reconstruction Algorithms on Myocardial Blood Flow Measurement with 13N-Ammonia PET JF Journal of Nuclear Medicine JO J Nucl Med FD Society of Nuclear Medicine SP 1259 OP 1265 DO 10.2967/jnumed.106.038232 VO 48 IS 8 A1 Grace P. Chen A1 Kelley R. Branch A1 Adam M. Alessio A1 Pam Pham A1 Ramin Tabibiazar A1 Paul Kinahan A1 James H. Caldwell YR 2007 UL http://jnm.snmjournals.org/content/48/8/1259.abstract AB Filtered backprojection (FBP) is the traditional method for 13N-NH3 PET studies. Ordered-subsets expectation maximization (OSEM) is popular for PET studies because of better noise properties. Scant data exist on the effect of reconstruction algorithms on quantitative myocardial blood flow (MBF) estimation. Methods: Twenty patients underwent dynamic acquisition rest/stress 13N-NH3 studies. In Part 1, 19 rest/stress image pairs were reconstructed by FBP (10-mm Hanning filter) and by OSEM with 28 subsets and 2 (OSEM2), 6 (OSEM6), or 8 iterations (OSEM8), and a 10-mm postreconstruction smoothing gaussian filter. In Part 2, 9 image pairs were reconstructed by FBP (10-mm Hanning filter) and by OSEM with 28 subsets, 8 iterations, and a gaussian 5-, 10-, or 15-mm postreconstruction smoothing filter. Average MBF (mL/min/mL of myocardium) was calculated using a 3-compartment model. Results: Part 1: For rest MBF, the correlations between FBP and each of the OSEM algorithms were r2 = 0.71, 0.73, and 0.77, respectively. MBF by OSEM6 (0.98 ± 0.48 [mean ± SD]) and OSEM8 (0.96 ± 0.46) was not significantly different from FBP (1.02 ± 0.39), but OSEM2 (0.80 ± 0.37) was significantly lower (P < 0.0003). With stress, the correlations were high between FBP and OSEM6 and OSEM8 (r2 = 0.85 and 0.90), and MBF by OSEM6 and OSEM8 was not significantly different from FBP. Part 2: Resting MBF correlated well between FBP and all OSEM smoothing filters (r2 = 0.82, 0.85, and 0.88). Rest MBF using postsmoothing 5- or 10-mm filters was not different from FBP but was significantly lower with the 15-mm filter (P < 0.05). With stress, the correlations were good between FBP and OSEM regardless of smoothing (r2 = 0.76, 0.77, and 0.79). However, MBF with postsmoothing 10- and 15-mm filters was significantly lower than by FBP (P < 0.05). Conclusion: Reconstruction algorithms significantly affect the estimation of quantitative blood flow data and should not be assumed to be interchangeable. Although aggressive smoothing may produce visually appealing images with reduced noise levels, it may cause an underestimation of absolute quantitative MBF. In selecting a reconstruction algorithm, an optimal balance between noise properties and diagnostic accuracy must be emphasized.