PT - JOURNAL ARTICLE AU - Michael C. Kreissl AU - Hsiao-Ming Wu AU - David B. Stout AU - Waldemar Ladno AU - Thomas H. Schindler AU - Xiaoli Zhang AU - John O. Prior AU - Mayumi L. Prins AU - Arion F. Chatziioannou AU - Sung-Cheng Huang AU - Heinrich R. Schelbert TI - Noninvasive Measurement of Cardiovascular Function in Mice with High-Temporal-Resolution Small-Animal PET DP - 2006 Jun 01 TA - Journal of Nuclear Medicine PG - 974--980 VI - 47 IP - 6 4099 - http://jnm.snmjournals.org/content/47/6/974.short 4100 - http://jnm.snmjournals.org/content/47/6/974.full SO - J Nucl Med2006 Jun 01; 47 AB - The aim of this study was to explore the feasibility of determining parameters of cardiovascular function in mice noninvasively by high-temporal-resolution imaging with a dedicated small-animal PET system. Methods: Twenty-five anesthetized mice (28.8 ± 4.6 g) were injected via an intravenous catheter with a 30-μL bolus of 18F-FDG (8–44 MBq). The first 9 s of data were reconstructed into 30 frames of 0.3 s using filtered backprojection. The time–activity curve derived from a left ventricle volume of interest was corrected for tracer recirculation and partial volume. Cardiac output was calculated by the Stewart-Hamilton method, in which cardiac output is total injected activity divided by the area under the left ventricle time–activity curve. Cardiac output divided by body weight was defined as cardiac index; cardiac output divided by heart rate yielded the stroke volume. In 5 mice, measurements were repeated 2–4 times to assess reproducibility. In 4 mice, the hemodynamic response to dobutamine was examined by measuring heart rate, cardiac output, and stroke volume. Results: The cardiac output averaged 20.4 ± 3.4 mL/min; in the repeated measurements, the parameter displayed a mean percentage SD per mouse of 10% ± 6%. The cardiac index averaged 0.73 ± 0.19 mL/min/g and the stroke volume 45.0 ± 6.9 μL, and both correlated with heart rate (r = 0.53, P = 0.007, and r = 0.49, P = 0.01, respectively). During dobutamine stress, heart rate increased from 423 ± 50 to 603 ± 30 beats/min (P = 0.002) and cardiac output increased from 18.5 ± 1.9 to 32.0 ± 4.2 mL/min (P = 0.008). Conclusion: Parameters of cardiovascular function can be measured in mice noninvasively by radionuclide angiography using high-temporal-resolution small-animal PET. Measured values of cardiac output and stroke volume are reproducible and comparable to those obtained with MRI. The approach permits the monitoring of changes in cardiovascular function in response to pharmacologic intervention.