RT Journal Article SR Electronic T1 Dynamic Imaging of Striatal D2 Receptors in Mice Using Quad-HIDAC PET JF Journal of Nuclear Medicine JO J Nucl Med FD Society of Nuclear Medicine SP 464 OP 470 VO 45 IS 3 A1 Honer, Michael A1 Brühlmeier, Matthias A1 Missimer, John A1 Schubiger, August P. A1 Ametamey, Simon M. YR 2004 UL http://jnm.snmjournals.org/content/45/3/464.abstract AB The novel, dedicated small animal PET tomograph, quad-HIDAC, offers submillimeter resolution in instrumental characterization experiments. The aim of this study was to establish the tomograph’s utility in a biologic application and to demonstrate the feasibility of rapid dynamic neuroreceptor imaging in mice. Methods: We used the well-established, high-affinity dopamine D2 receptor PET ligand 18F-fallypride for imaging striatal D2 receptors in NMRI mice. Dynamic PET data were acquired using the quad-HIDAC tomograph and subject to 2 different kinetic modeling approaches. The cerebellum, a brain region devoid of D2 receptors, was chosen as a reference region for kinetic modeling. Results: The resolution of the quad-HIDAC camera allowed clear visualization of the left and right mouse striatum with high target-to-nontarget signal ratios. The sensitivity of the tomograph permitted the generation of time-activity curves with initial time frames of 120 s. PET experiments acquiring data for 150 min demonstrated that the binding potential of 18F-fallypride could be fitted robustly with both reference tissue models for scan durations of ≥40 min. Voxel-wise modeling resulted in parametric maps of high quality. The values for the binding potential in the striatum reached approximately 14, consistent with striatum-to-cerebellum ratios extracted from regional time-activity curves. Comparison of in vivo PET imaging results with ex vivo postmortem tissue sampling analyses indicated discrepancies in signal intensity, possibly resulting from scatter and random background in the cerebellum region of interest and leading to an overestimation of cerebellar activity concentrations and degradation of striatum-to-cerebellum ratios in PET experiments. Intraperitoneal injection of the unlabeled D2 receptor antagonist haloperidol 30 min before intravenous injection of 18F-fallypride blocked tracer accumulation in the striatum by >95%. Conclusion: The quad-HIDAC camera represents a powerful tool for future dynamic neuroreceptor PET studies in mice and rats under numerous pharmacologic or pathophysiologic conditions.