TY - JOUR T1 - Prognostic Value of PET Using <sup>18</sup>F-FDG in Hodgkin’s Disease for Posttreatment Evaluation JF - Journal of Nuclear Medicine JO - J Nucl Med SP - 1225 LP - 1231 VL - 44 IS - 8 AU - Christian Guay AU - Mariette Lépine AU - Jean Verreault AU - François Bénard Y1 - 2003/08/01 UR - http://jnm.snmjournals.org/content/44/8/1225.abstract N2 - Detection of relapse after completion of therapy in patients with Hodgkin’s disease (HD) and non-Hodgkin’s lymphomas (NHL) constitutes an important challenge in modern medical imaging. An accurate assessment of the presence of residual disease is essential to determine which patients would benefit from additional therapy. The objective of this study was to assess the diagnostic accuracy of 18F-FDG PET in detecting residual disease or relapse during the posttherapy period in patients with HD in comparison with CT. We also established different predictive values for 18F-FDG PET according to the time interval between the end of therapy and the PET study. Methods: Forty-eight patients with HD underwent 18F-FDG PET after the completion of chemotherapy (median, 58 d) between March 1999 and April 2002. Disease-free intervals and proportions were calculated using the Kaplan–Meier method. Standardized uptake values of the most active lesion in each patient with a positive study were also measured. PET and CT results were compared with clinical follow-up, with relapse being defined by a positive biopsy or the introduction of a second-line treatment. Results: Thirty-four patients were still disease-free during a mean follow-up of 605 d. Fourteen patients relapsed during a mean follow-up of 197 d. The sensitivity and specificity of 18F-FDG PET to predict relapse were 79% and 97%, respectively. The positive predictive value and the negative predictive value were both equal to 92%. The diagnostic accuracy of 18F-FDG PET (92%) was significantly higher than the accuracy of CT (56%) (P &lt; 0.0005). Patients with positive 18F-FDG PET also had a far shorter median disease-free interval (79 d) than those with positive CT (disease-free proportion of 52% at 1,143 d) (P = 0.0046). The 3 cases of false-negative 18F-FDG PET studies that we observed occurred in patients who underwent their PET study within the first 49 d after the end of chemotherapy. Conclusion: Positive 18F-FDG PET after the end of therapy in HD patients is a strong predictor of relapse. A negative PET study is also an excellent predictor of good prognosis. The diagnostic accuracy of 18F-FDG PET to assess the presence of residual disease after therapy is superior to that of CT. ER -