TY - JOUR T1 - Effects of <sup>90</sup>Y-Microspheres on Liver Tumors: Comparison of Intratumoral Injection Method and Intra-Arterial Injection Method JF - Journal of Nuclear Medicine JO - J Nucl Med SP - 1892 LP - 1897 VL - 41 IS - 11 AU - Wan-Yu Lin AU - Shih-Chuan Tsai AU - Jih-Fang Hsieh AU - Shyh-Jen Wang Y1 - 2000/11/01 UR - http://jnm.snmjournals.org/content/41/11/1892.abstract N2 - Internal radiation therapy using intrahepatic arterial injection of 90Y-labeled glass microspheres (90Y-microspheres) has proven to be a promising therapeutic modality for inoperative liver tumor. Recently, direct intratumoral injection of 90Y-microspheres has been performed with even more encouraging results. The purpose of this study was to compare the treatment efficacy of these 2 methods using 90Y-microspheres. Methods: Forty-eight male rats, each bearing a hepatic tumor, were divided into 4 groups (12 rats in each group) to evaluate the efficacy of treatment. Group 1 received an intratumoral injection of 37 MBq (1 mCi) 90Y-microspheres. Group 2 received an intratumoral injection of 0.1 mL normal saline as the control group. Group 3 received an intra-arterial injection of 37 MBq (1 mCi) 90Y-microspheres. Group 4 received an intra-arterial injection of 0.1 mL normal saline as the control group. Tumor size was measured by liver sonography before injection as well as at 2 and 4 wk after injection. Survival time was calculated from the day of treatment to 2 mo after treatment by Kaplan-Meier survival analysis. The response rate was evaluated by the change in tumor size and survival time. Fisher's exact, 2-tailed test was used to compare response rates. Results: In the rats treated by intratumoral injection of 90Y-microspheres, 83.3% (10/12) showed a good response. In contrast, all 12 rats in the control group showed a poor response. The difference was significant (P &lt; 0.00001). Eighty-three percent (10/12) of the rats survived &gt;60 d after intratumoral injection of 90Y-microspheres, whereas only 25% (3/12) of the control rats survived &gt;60 d. The difference was significant (P = 0.0068). In the rats treated by intra-arterial injection of 90Y-microspheres, 58.3% (7/12) showed a good response to the treatment. All rats in the control group showed a poor response. The difference was significant (P = 0.0023). Sixty-six percent (8/12) of the rats survived &gt;60 d after intra-arterial injection of 90Y-microspheres, whereas only 16.7% (2/12) of the control rats survived &gt;60 d. The difference was significant (P = 0.0385). However, the response rate and survival time between the intratumoral treatment group and the intra-arterial treatment group showed no significant difference (P = 0.3707 and 0.3988, respectively). Conclusion: Both methods (intratumoral treatment and intra-arterial treatment) showed a significantly good response rate and prolonged survival time compared with those of the control groups. However, no significant difference was found in the response rate or survival time between intratumoral treatment and intra-arterial treatment. ER -