RT Journal Article
SR Electronic
T1 A Pilot Study of 68Ga-PSMA11 and 68Ga-RM2 PET/MRI for Biopsy Guidance in Patients with Suspected Prostate Cancer
JF Journal of Nuclear Medicine
JO J Nucl Med
FD Society of Nuclear Medicine
SP 744
OP 750
DO 10.2967/jnumed.122.264448
VO 64
IS 5
A1 Duan, Heying
A1 Ghanouni, Pejman
A1 Daniel, Bruce
A1 Rosenberg, Jarrett
A1 Thong, Alan
A1 Kunder, Christian
A1 Aparici, Carina Mari
A1 Davidzon, Guido A.
A1 Moradi, Farshad
A1 Sonn, Geoffrey A.
A1 Iagaru, Andrei
YR 2023
UL http://jnm.snmjournals.org/content/64/5/744.abstract
AB Targeting of lesions seen on multiparametric MRI (mpMRI) improves prostate cancer (PC) detection at biopsy. However, 20%–65% of highly suspicious lesions on mpMRI (PI-RADS [Prostate Imaging-Reporting and Data System] 4 or 5) are false-positives (FPs), while 5%–10% of clinically significant PC (csPC) are missed. Prostate-specific membrane antigen (PSMA) and gastrin-releasing peptide receptors (GRPRs) are both overexpressed in PC. We therefore aimed to evaluate the potential of 68Ga-PSMA11 and 68Ga-RM2 PET/MRI for biopsy guidance in patients with suspected PC. Methods: A highly selective cohort of 13 men, aged 58.0 ± 7.1 y, with suspected PC (persistently high prostate-specific antigen [PSA] and PSA density) but negative or equivocal mpMRI results or negative biopsy were prospectively enrolled to undergo 68Ga-PSMA11 and 68Ga-RM2 PET/MRI. PET/MRI included whole-body and dedicated pelvic imaging after a delay of 20 min. All patients had targeted biopsy of any lesions seen on PET followed by standard 12-core biopsy. The SUVmax of suspected PC lesions was collected and compared with gold standard biopsy. Results: PSA and PSA density at enrollment were 9.8 ± 6.0 (range, 1.5–25.5) ng/mL and 0.20 ± 0.18 (range, 0.06–0.68) ng/mL2, respectively. Standardized systematic biopsy revealed a total of 14 PCs in 8 participants: 7 were csPC and 7 were nonclinically significant PC (ncsPC). 68Ga-PSMA11 identified 25 lesions, of which 11 (44%) were true-positive (TP) (5 csPC). 68Ga-RM2 showed 27 lesions, of which 14 (52%) were TP, identifying all 7 csPC and also 7 ncsPC. There were 17 concordant lesions in 11 patients versus 14 discordant lesions in 7 patients between 68Ga-PSMA11 and 68Ga-RM2 PET. Incongruent lesions had the highest rate of FP (12 FP vs. 2 TP). SUVmax was significantly higher for TP than FP lesions in delayed pelvic imaging for 68Ga-PSMA11 (6.49 ± 4.14 vs. 4.05 ± 1.55, P = 0.023) but not for whole-body images, nor for 68Ga-RM2. Conclusion: Our results show that 68Ga-PSMA11 and 68Ga-RM2 PET/MRI are feasible for biopsy guidance in suspected PC. Both radiopharmaceuticals detected additional clinically significant cancers not seen on mpMRI in this selective cohort. 68Ga-RM2 PET/MRI identified all csPC confirmed at biopsy.