PT - JOURNAL ARTICLE AU - Fukami, Mitsuha AU - Matsutomo, Norikazu AU - Takeyuki, Hashimoto AU - Yamamoto, Tomoaki AU - Sasaki, Masayuki TI - <strong>The application of compressed sensing reconstruction for myocardial perfusion image shortens the acquisition time: a simulation study</strong> DP - 2022 Aug 01 TA - Journal of Nuclear Medicine PG - 4097--4097 VI - 63 IP - supplement 2 4099 - http://jnm.snmjournals.org/content/63/supplement_2/4097.short 4100 - http://jnm.snmjournals.org/content/63/supplement_2/4097.full SO - J Nucl Med2022 Aug 01; 63 AB - 4097 Introduction: The compressed sensing (CS) theory has been applied to medical image reconstruction to improve the quality of sparse single-photon emission computed tomography (SPECT) images. It enables a dynamic study on the calculation of myocardial flow reserve with a general gamma camera if CS reconstruction is applied for time reduction in myocardial perfusion images (MPIs). Thus, this initial study aimed to evaluate the performance of CS-iterative reconstruction (IR) compared to filtered back-projection (FBP) and maximum likelihood expectation maximization (ML-EM) toward the reduction of acquisition time of MPI.Methods: Digital phantom that mimicked the left ventricular myocardium was made for simulation. The projection data were simulated with 120 projection (360&amp;deg;) and 60 projection (180&amp;deg;) by SIMIND Monte Carlo programs. The SPECT image was reconstructed by FBP, ML-EM, and CS-IR. The coefficient of variation (CV) for uniformity of myocardial accumulation, full width at half maximum (FWHM) of the septal wall, and contrast ratio of the defect/normal lateral wall were calculated for evaluation. The simulation was performed ten times, and all data were expressed as mean ± standard deviation. Tukey-Kramer test was used for statistical analysis.Results: In SPECT images with 360&amp;deg; acquisition, the CV with CS-IR (0.133 ± 0.006) was significantly lower than FBP (0.222 ± 0.003) and ML-EM (0.201 ± 0.003) (P &lt; 0.05). Conversely, the FWHM with CS-IR was minimally deteriorated by 2.41 mm, compared to those of other reconstruction algorithms. The contrast ratio was not significantly different between the FBP and CS-IR. The results for 180&amp;deg; acquisition were almost the same as those of 360&amp;deg; acquisition.Conclusions: The uniformity with CS-IR was superior to that with FBP and ML-EM. CS-IR is expected to be useful for the reduction of acquisition time and calculation of myocardial flow reserve.