RT Journal Article SR Electronic T1 Objective task-based evaluation of a deep-learning-based segmentation method for quantitative SPECT JF Journal of Nuclear Medicine JO J Nucl Med FD Society of Nuclear Medicine SP 3200 OP 3200 VO 63 IS supplement 2 A1 Ziping Liu A1 Zekun Li A1 Abhinav Jha YR 2022 UL http://jnm.snmjournals.org/content/63/supplement_2/3200.abstract AB 3200 Introduction: Quantitative SPECT (QSPECT) is showing significant promise in multiple clinical applications. In many of these applications, the task is quantifying the mean uptake within region(s) of interest. Reliable quantification requires accurate segmentation of these regions on the SPECT images. However, SPECT segmentation is challenging, a major reason being partial-volume effects. To address this challenge, we recently proposed a deep-learning (DL)-based segmentation method that estimates the fractional volume occupied by each considered region within each image-voxel (Liu et al. 2021a). The method was evaluated in the context of segmenting DaTscan SPECT images (Liu et al. 2021b), and was observed to yield accurate segmentation performance with high Dice scores and significantly outperform conventional methods. However, for clinical translation of this method for QSPECT, it is important that the method is evaluated on the clinical task of quantifying regional uptake. The aim of our study was to conduct this objective task-based evaluation.Methods: To objectively evaluate segmentation methods for QSPECT, it is important that the procedure to quantify regional uptake should be optimal when the true boundaries of considered regions are known. The typical process of quantifying regional uptake from OSEM-reconstructed SPECT images is sub-optimal since these estimates are known to be biased and/or imprecise. Thus, such procedure is not suitable to objectively evaluate segmentation methods. In this context, an optimal procedure is projection-domain quantification (PDQ). The PDQ is a maximum-likelihood technique that estimates regional uptake directly from projection data by accurately modeling the imaging-system physics. Given the true segmentations, the PDQ approach yields an unbiased estimate of regional uptake with a variance close to Cramér-Rao bound (Li et al. 2021). Thus, when using the PDQ approach to evaluate a segmentation method, any error in the measured regional uptake would be due to the error in segmentation. Thus, we used the PDQ approach to objectively evaluate the proposed method.The proposed method was evaluated on the clinical task of quantifying regional uptake in caudate, putamen and globus pallidus from DaTscan SPECT. The evaluation was conducted using clinically realistic simulations with the details presented in Liu et al. (2021b). We generated 100 test digital brain phantoms with clinically relevant DaT activity distributions. From these activity distributions, realistic projection data were simulated using SIMIND by modeling all the relevant image-degrading processes and by following the practice guideline for DaTscan SPECT acquisition. The projection data were reconstructed using an OSEM algorithm that compensated for attenuation, scatter, and collimator-detector response. The proposed method was applied to segment the considered regions from the reconstructed SPECT images. We then used the PDQ approach to estimate the uptake within these segmented regions directly from the projection data. The performance of the proposed method was assessed using ensemble normalized bias (NB) and normalized RMSE (NRMSE) between the estimated and true uptake. The proposed method was also compared to a state-of-the-art U-net-based method based on these metrics. Results: Fig. 1 shows the ensemble NB and NRMSE of the estimates yielded by the proposed and U-net-based methods. The proposed method yielded low NB < 10% and NRMSE < 20% for all regions, demonstrating both accurate and precise quantification. The proposed method also outperformed the U-net-based method based on ensemble NB and NRMSE.Conclusions: The proposed deep-learning-based segmentation method yielded accurate and precise quantification of regional uptake from DaTscan SPECT. These results motivate further clinical evaluation of the method. Further, we outlined a framework to objectively evaluate segmentation methods for quantitative SPECT on the task of regional uptake quantification.