TY - JOUR T1 - <sup>18</sup>F-Fluorodihydroxyphenylalanine PET/CT at the Forefront for Initial and/or Pre-surgical Evaluation of Small Intestine Neuroendocrine Tumors JF - Journal of Nuclear Medicine JO - J Nucl Med DO - 10.2967/jnumed.122.263984 SP - jnumed.122.263984 AU - Eric Ouvrard AU - Louis De Mestier AU - Caroline Boursier AU - Boumediene Lachachi AU - Nicolas Sahakian AU - Elodie Chevalier AU - Nidaa Mikail AU - Josefina Carullo AU - Aurélie Bando-Delaunay AU - Thomas Walter AU - Gabriel G. Malouf AU - Pietro Addeo AU - Gilles Poncet AU - Frederic Sebag AU - Rachida Lebtahi AU - Bernard Goichot AU - David Taïeb AU - Alessio Imperiale Y1 - 2022/05/01 UR - http://jnm.snmjournals.org/content/early/2022/05/19/jnumed.122.263984.abstract N2 - To compare the respective value of 68Ga-DOTATOC and 18F-DOPA PET/CT for initial staging or pre-surgical work-up of patients with small intestine neuroendocrine tumors (SiNET). Methods: This is a retrospective, multicenter, non-interventional investigation involving 53 non-operated SiNET patients who underwent both 68Ga-DOTATOC and 18F-DOPA PET/CT within a 6-months interval without therapeutic intervention or change between the two PET/CT studies. Detection rate (DR %) was calculated according to per-region and per-lesion analyses. Sensitivity for primary tumor detection was assessed in 37 operated patients taking surgical results (76 SiNET) as diagnostic gold standard. Results: Each of 68Ga-DOTATOC PET/CT and 18F-DOPA PET/CT individually identified at least one primary SiNET in 92% (34/37) of the patients. Tumor intestinal multifocality was confirmed by histology in 8 patients. 68Ga-DOTATOC and 18F-DOPA PET/CT were concordant positive for tumor multifocality in 5, discordant positive in 2, and concordant negative in 1 case. DR % for subdiaphragmatic nodal metastases on per-region-based analysis was 91 % and 98 % for 68Ga-DOTATOC and 18F-DOPA PET/CT, respectively (P = 0.18). 18F-DOPA PET/CT detected a higher number of abnormal subdiaphragmatic nodes (P = 0.009). Regarding mesenteric nodes only, 18F-DOPA PET/CT detected more positive regions (P = 0.005) and nodal lesions (P = 0.003) than 68Ga-DOTATOC PET/CT, including nodes located at the origin of mesenteric vessels. For detection of distant metastases, 68Ga-DOTATOC and 18F-DOPA PET/CT performed equally on a per-region-based analysis. As compared to 68Ga-DOTATOC, 18F-DOPA PET/CT detected more hepatic (p&lt;0.001), peritoneal (p&lt;0.001), and lung metastases (p&lt;0.001). Conclusion: 18F-DOPA PET/CT detects more lesions than 68Ga-DOTATOC PET/CT in studied patients. Their respective role should be discussed in terms of disease staging and treatment selection. ER -