RT Journal Article SR Electronic T1 Anti-CEA Pretargeted Immuno-PET Shows Higher Sensitivity Than DOPA PET/CT in Detecting Relapsing Metastatic Medullary Thyroid Carcinoma: Post Hoc Analysis of the iPET-MTC Study JF Journal of Nuclear Medicine JO J Nucl Med FD Society of Nuclear Medicine SP 1221 OP 1227 DO 10.2967/jnumed.120.252791 VO 62 IS 9 A1 Caroline Bodet-Milin A1 Alain Faivre-Chauvet A1 Thomas Carlier A1 Catherine Ansquer A1 Aurore Rauscher A1 Eric Frampas A1 Frederique Toulgoat A1 Damien Masson A1 Mickael Bourgeois A1 Evelyne Cerato A1 Vincent Rohmer A1 Olivier Couturier A1 Delphine Drui A1 David M. Goldenberg A1 Robert M. Sharkey A1 Jacques Barbet A1 Francoise Kraeber-Bodere YR 2021 UL http://jnm.snmjournals.org/content/62/9/1221.abstract AB Pretargeting parameters for the use of anti–carcinoembryonic antigen (CEA) bispecific monoclonal antibody TF2 and the 68Ga-labeled IMP288 peptide for immuno-PET have been optimized in a first-in-humans study performed on medullary thyroid carcinoma (MTC) patients (the iPET-MTC study). The aim of this post hoc analysis was to determine the sensitivity of immuno-PET in relapsing MTC patients, in comparison with conventional imaging and 18F-l-dihydroxyphenylalanine (18F-DOPA) PET/CT. Methods: Twenty-five studies were analyzed in 22 patients. All patients underwent immuno-PET 1 and 2 h after 68Ga-IMP288 injection pretargeted by TF2, in addition to neck, thoracic, abdominal, and pelvic CT; bone and liver MRI; and 18F-DOPA PET/CT. The gold standard was histology or confirmation by one other imaging method or by imaging follow-up. Results: In total, 190 lesions were confirmed by the gold standard: 89 in lymph nodes, 14 in lungs, 46 in liver, 37 in bone, and 4 in other sites (subcutaneous tissue, heart, brain, and pancreas). The number of abnormal foci detected by immuno-PET was 210. Among these, 174 (83%) were confirmed as true-positive by the gold standard. Immuno-PET showed a higher overall sensitivity (92%) than 18F-DOPA PET/CT (65%). Regarding metastatic sites, immuno-PET had a higher sensitivity than CT, 18F-DOPA PET/CT, or MRI for lymph nodes (98% vs. 83% for CT and 70% for 18F-DOPA PET/CT), liver (98% vs. 87% for CT, 65% for 18F-DOPA PET/CT, and 89% for MRI), and bone (92% vs. 64% for 18F-DOPA PET/CT and 86% for MRI), whereas sensitivity was lower for lung metastases (29% vs. 100% for CT and 14% for 18F-DOPA PET/CT). Tumor SUVmax at 60 min ranged from 1.2 to 59.0, with intra- and interpatient variability. Conclusion: This post hoc study demonstrates that anti–carcinoembryonic antigen immuno-PET is an effective procedure for detecting metastatic MTC lesions. Immuno-PET showed a higher overall sensitivity than 18F-DOPA PET/CT for disclosing metastases, except for the lung, where CT remains the most effective examination.