RT Journal Article SR Electronic T1 Radiation Dosimetry of 99mTc-PSMA I&S: A Single-Center Prospective Study JF Journal of Nuclear Medicine JO J Nucl Med FD Society of Nuclear Medicine SP 1075 OP 1081 DO 10.2967/jnumed.120.253476 VO 62 IS 8 A1 Urbán, Szabolcs A1 Meyer, Catherine A1 Dahlbom, Magnus A1 Farkas, István A1 Sipka, Gábor A1 Besenyi, Zsuzsanna A1 Czernin, Johannes A1 Calais, Jeremie A1 Pávics, László YR 2021 UL http://jnm.snmjournals.org/content/62/8/1075.abstract AB 99mTc-PSMA I&S is a prostate-specific membrane antigen (PSMA) tracer that can be used for planar and SPECT/CT γ-imaging and radioguided surgery. The primary aim of this study was to estimate the dosimetry of 99mTc-PSMA I&S using a hybrid method (sequential γ-planar imaging and 1 single SPECT/CT) in healthy volunteers. The secondary aim was to depict the tracer biodistribution and tumor-to-background ratios (TBRs) in patients with prostate cancer (PCa). Methods: Dosimetry of 99mTc-PSMA I&S was investigated in 4 healthy volunteers. Whole-body planar imaging was acquired at 1, 2, 3, 6, and 24 h and SPECT/CT at 6 h after tracer injection. Contours of organs were drawn on all acquisitions to determine organ activity at each time point. Absorbed dose was estimated using 2 methods: independent curve-fitting manual method (Levenberg-Marquardt–based algorithm using dose factors from RAdiation Dose Assessment Resource [RADAR] website) and OLINDA/EXM software (version 2.0; HERMES Medical Solutions). Biodistribution of 99mTc-PSMA I&S was assessed in 10 patients with PCa on SPECT/CT images at 6 h. Tumor uptake (SUVmax), and TBR (tumor SUVmax/background organ SUVmean) using muscle (T/M), bladder (T/B), and intestine (T/I) as background organs were determined. Results: The mean injected activity of 99mTc-PSMA I&S was 717 MBq (range: 562–828 MBq). No adverse events related to the injection of 99mTc-PSMA I&S were reported. The average radiation effective dose was 0.0055 mSv/MBq with the RADAR manual method and 0.0052 mSv/MBq with OLINDA/EXM. Total body effective dose ranged between 3.33–4.42 and 3.11–4.23 mSv, respectively. All PCa patients showed high tracer uptake in primary and metastatic lesions with T/M, T/B, and T/I ranging from 5.29–110, 0.11–7.02, and 0.96–16.30, respectively. Conclusion: Effective doses of 99mTc-PSMA I&S were comparable to those known for most of the 99mTc tracers and was lower than for the 68Ga-labeled and 18F-labeled agents. 99mTc-PSMA I&S SPECT/CT showed high TBR in PCa patients. This study can provide required data for translation and approval of 99mTc-PSMA I&S by regulatory agencies.