Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Permissions
    • Advertisers
    • Continuing Education
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Permissions
    • Advertisers
    • Continuing Education
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Follow JNM on Twitter
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Subscribe to our RSS feeds
OtherBasic Science (Animal or Phantoms)

Comparison of the Accuracy of FMT/CT and PET/MRI for the Assessment of Antibody Biodistribution in Squamous Cell Carcinoma Xenografts

Carina Hage, Felix Gremse, Christoph M Griessinger, Andreas Maurer, Sabrina H.L. Hoffmann, Franz Osl, Bernd J Pichler, Fabian Kiessling, Werner Scheuer and Thomas Pöschinger
Journal of Nuclear Medicine August 2017, jnumed.117.197178; DOI: https://doi.org/10.2967/jnumed.117.197178
Carina Hage
1 Roche Innovation Center Munich, Germany;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Felix Gremse
2 RWTH University Aachen, Germany;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Christoph M Griessinger
3 University of Tübingen, Germany;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Andreas Maurer
3 University of Tübingen, Germany;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Sabrina H.L. Hoffmann
3 University of Tübingen, Germany;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Franz Osl
1 Roche Innovation Center Munich, Germany;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Bernd J Pichler
3 University of Tübingen, Germany;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Fabian Kiessling
4 University of Aachen (RWTH), Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Werner Scheuer
1 Roche Innovation Center Munich, Germany;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Thomas Pöschinger
1 Roche Innovation Center Munich, Germany;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF
Loading

Abstract

Non-invasive imaging technologies are increasingly used in preclinical drug research for the pharmacokinetic analysis of therapeutic compounds in living animals over time. The different preclinical imaging modalities available differ intrinsically in their detection principle and thus might exhibit limitations for a specific application. Here, we systematically investigated the performance of advanced fluorescence mediated tomography/micro-computed tomography (FMT/CT) in comparison to positron emission tomography/magnetic resonance imaging (PET/MRI) for quantitative analysis of the biodistribution of different antibody formats and in dependence of the required imaging label in a squamous cell carcinoma xenograft model. Methods: Different formats of an anti-EGFR antibody (mAb, F(ab’)2 and Fab) were labeled with Alexa750 or [64Cu]NODAGA and injected intravenously into separate cohorts of nude mice bearing subcutaneous A-431 tumors. Two and 24 h after injection, mice were measured by FMT/CT and PET/MRI. Probe accumulation was quantitatively assessed in organs and tumors. In vivo data were compared between modalities and correlated with ex vivo fluorescence, gamma counting and ECLIA analysis. Results: Both imaging methods faithfully monitored the biodistribution and elimination routes of the compounds and organs’ accumulation measured by FMT/CT and PET/MRI correlated significantly with ex vivo measurements. In addition, the accumulation in kidney, muscle and tumor tissue correlated between FMT/CT and PET/MRI. However, the pharmacokinetic of the Alexa750-labeled antibody formats showed shorter blood half-life times and higher liver uptake than the radio-labeled counterparts. Conclusion: FMT/CT imaging allows quantifying the biodistribution of antibodies in nude mice and provides an alternative to classical PET analysis in preclinical drug research. However, even for large molecules, such as mAb, Alexa750-labeling can change pharmacokinetics and trigger liver uptake.

  • Animal Imaging
  • Optical
  • PET/MRI
  • Animal Imaging
  • Biodistribution
  • FMT/CT
  • Optical Imaging
  • PET/MRI
  • Copyright © 2017 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Next
Back to top

In this issue

Journal of Nuclear Medicine: 64 (2)
Journal of Nuclear Medicine
Vol. 64, Issue 2
February 1, 2023
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
  • Complete Issue (PDF)
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Comparison of the Accuracy of FMT/CT and PET/MRI for the Assessment of Antibody Biodistribution in Squamous Cell Carcinoma Xenografts
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Comparison of the Accuracy of FMT/CT and PET/MRI for the Assessment of Antibody Biodistribution in Squamous Cell Carcinoma Xenografts
Carina Hage, Felix Gremse, Christoph M Griessinger, Andreas Maurer, Sabrina H.L. Hoffmann, Franz Osl, Bernd J Pichler, Fabian Kiessling, Werner Scheuer, Thomas Pöschinger
Journal of Nuclear Medicine Aug 2017, jnumed.117.197178; DOI: 10.2967/jnumed.117.197178

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Comparison of the Accuracy of FMT/CT and PET/MRI for the Assessment of Antibody Biodistribution in Squamous Cell Carcinoma Xenografts
Carina Hage, Felix Gremse, Christoph M Griessinger, Andreas Maurer, Sabrina H.L. Hoffmann, Franz Osl, Bernd J Pichler, Fabian Kiessling, Werner Scheuer, Thomas Pöschinger
Journal of Nuclear Medicine Aug 2017, jnumed.117.197178; DOI: 10.2967/jnumed.117.197178
del.icio.us logo Digg logo Reddit logo Twitter logo CiteULike logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF

Related Articles

  • This Month in JNM
  • PubMed
  • Google Scholar

Cited By...

  • Optical Imaging Modalities: Principles and Applications in Preclinical Research and Clinical Settings
  • Development of a Gold Nanoparticle-Functionalized Surface Plasmon Resonance Assay for the Sensitive Detection of Monoclonal Antibodies and Its Application in Pharmacokinetics
  • Google Scholar

Similar Articles

Keywords

  • Animal Imaging
  • Optical
  • PET/MRI
  • Biodistribution
  • FMT/CT
  • optical imaging
SNMMI

© 2023 Journal of Nuclear Medicine

Powered by HighWire