Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Permissions
    • Advertisers
    • Continuing Education
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Permissions
    • Advertisers
    • Continuing Education
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Follow JNM on Twitter
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Subscribe to our RSS feeds
Research ArticleClinical Investigation
Open Access

Eligibility for 177Lu-PSMA Therapy Depends on the Choice of Companion Diagnostic Tracer: A Comparison of 68Ga-PSMA-11 and 99mTc-MIP-1404 in Metastatic Castration-Resistant Prostate Cancer

Gary J.R. Cook, Wai-Lup Wong, Bal Sanghera, Stephen Mangar, Amarnath Challapalli, Amit Bahl, Paul Bassett, Darren Leaning and Christian Schmidkonz
Journal of Nuclear Medicine February 2023, 64 (2) 227-231; DOI: https://doi.org/10.2967/jnumed.122.264296
Gary J.R. Cook
1Cancer Imaging Department, School of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Wai-Lup Wong
2Paul Strickland Scanner Centre, Mount Vernon Hospital, Northwood, Northwood, United Kingdom;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Bal Sanghera
2Paul Strickland Scanner Centre, Mount Vernon Hospital, Northwood, Northwood, United Kingdom;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Stephen Mangar
3Department of Oncology, Charing Cross Hospital, Imperial College Healthcare NHS Trust, London, United Kingdom;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Amarnath Challapalli
4Department of Clinical Oncology, Bristol Cancer Institute, Bristol, United Kingdom;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Amit Bahl
4Department of Clinical Oncology, Bristol Cancer Institute, Bristol, United Kingdom;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Paul Bassett
5Statsconsultancy Ltd, Amersham, United Kingdom;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Darren Leaning
6Department of Clinical Oncology, James Cook University Hospital, South Tees NHS Trust, Middlesbrough, United Kingdom;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Christian Schmidkonz
7Department of Nuclear Medicine, University Hospital Erlangen, Erlangen, Germany; and
8Department of Industrial Engineering and Health, Technical University of Applied Sciences Amberg-Weiden, Weiden, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Visual Abstract

Figure
  • Download figure
  • Open in new tab
  • Download powerpoint

Abstract

177Lu-prostate-specific membrane antigen-617 (177Lu-PSMA-617) is an effective therapy for metastatic castration-resistant prostate cancer (mCRPC), with evidence of improved survival over standard care. The VISION trial inclusion criteria required a metastatic lesion-to-liver ratio of greater than 1 on 68Ga-PSMA-11 PET scans. We aimed to determine whether an equivalent ratio is suitable for a SPECT tracer, 99mTc-MIP-1404, and to compare lesion and lesion–to–normal-organ ratios between the 2 radiotracers. Methods: Two cohorts of patients with mCRPC matched for age, prostate-specific antigen level, and total Gleason score, with either 99mTc-MIP-1404 SPECT/CT (n = 25) or 68Ga-PSMA-11 PET/CT (n = 25) scans, were included for analysis. Up to 3 lesions in each site (prostate/prostate bed, lymph nodes, bone and soft-tissue metastases) as well as normal liver, parotid gland, spleen, and mediastinal blood-pool SUVmax were measured. Results: 99mTc-MIP-1404 SPECT lesion SUVmax was not significantly different from 68Ga-PSMA-11 PET (median, 18.2 vs. 17.3; P = 0.93). However, 99mTc-MIP-1404 liver SUVmax was higher (median, 8.5 vs. 5.8; P = 0.002) and lesion-to-liver ratios were lower (median, 2.7 vs. 3.5; P = 0.009). There was no significant difference in parotid gland or splenic SUVmax or lesion–to–parotid gland ratios between the 2 tracers although there was a small difference in lesion-to-spleen ratios (P = 0.034). Conclusion: There are differences in biodistribution and, in particular, liver activity, between 68Ga-PSMA-11 and 99mTc-MIP-1404. Therefore, if 99mTc-MIP-1404 is used to assess eligibility for 177Lu-PSMA-617 therapy, a lower adjusted lesion-to-liver ratio should be used.

  • 177Lu-PSMA-617
  • 68Ga-PSMA-11
  • 99mTc-MIP-1404

The therapeutic options for metastatic castration resistant prostate cancer (mCRPC) are rapidly expanding, especially in the area of targeted radionuclide therapy. In particular, exploiting prostate-specific membrane antigen (PSMA) overexpression in metastatic disease is an appealing option for targeted therapy (1). The recently reported VISION trial confirmed an improvement in progression-free survival and overall survival after treatment with radiolabeled PSMA therapy, 177Lu-PSMA-617 (2). In keeping with optimal practice and the principles of theranostics, and given the knowledge that some prostate cancers do not express PSMA, target expression was mandated by 68Ga-PSMA-11 PET imaging as an inclusion criterion (3). Specifically, the trial required at least 1 PSMA-positive metastasis, defined as uptake greater than liver with no PSMA-negative lesion (uptake ≤ liver) in any measurable metastasis (lymph node > 2.5 cm, solid organ > 1.0 cm, bone > 1.0 cm soft-tissue component). In the trial, 126 of 995 subjects did not meet imaging criteria.

The inclusion criteria were based on pragmatic reasons, including the widespread use and availability of 68Ga-PSMA-11 (2,3) and that screen failures were subsequently shown to have worse outcomes (4).

As eligibility for 177Lu-PSMA-617 therapy requires only a binary decision depending on the level of lesion uptake rather than requiring maximal sensitivity for lesion detection, several alternative PET and SPECT PSMA ligands exist that could potentially be used to confirm metastatic PSMA expression, some of which may be less costly or more readily available and accessible in different geographic areas of the world. These include other 68Ga-, 18F-, and 99mTc-labeled ligands that have demonstrated utility in detection of PSMA-expressing metastases in prostate cancer (5–12). For example, 99mTc-MIP-1404 has shown efficacy in patients with intermediate- and high-risk prostate cancer undergoing prostatectomy and extended pelvic lymph node dissection (5) and has favorable radiation dosimetry (0.0088 mSv/MBq) compared with 68Ga-PSMA-11 (0.022 mSv/MBq) (13,14). However, these ligands have biodistributions different from 68Ga-PSMA-11, and particularly in those where biliary rather than renal excretion predominates, the use of a lesion- to-liver ratio of greater than 1 may deny patients access to 177Lu-PSMA-617 treatment when 68Ga-PSMA-11 would have confirmed eligibility. There is therefore a need to determine appropriate quantitative criteria for different PSMA ligands to ensure equity of eligibility to 177Lu-PSMA-617 therapy.

Our aim was to compare the biodistributions of 68Ga-PSMA-11 and 99mTc-MIP-1404 (ROTOP Pharmaka GmbH) in metastases and potential reference organs in matched cohorts of patients with mCRPC. Our hypothesis was that differences in biodistributions would be present, requiring an appropriate equivalent metric for 99mTc-MIP-1404 to define treatment eligibility.

MATERIALS AND METHODS

Institutional approval was acquired for analysis of anonymized retrospective data without the need for further consent. Two cohorts of 25 consecutive patients who had undergone 68Ga-PSMA-11 PET/CT or 99mTc-MIP-1404 SPECT/CT scans were included in the analysis. Inclusion criteria were CRPC with metastatic disease being considered for systemic therapy including 177Lu-PSMA-617. Patients were excluded if they did not have mCRPC or information on a prostate-specific antigen (PSA) level within 1 mo of the PSMA scan or no history of the original Gleason score. Age, PSA level closest to the time of scanning, and original Gleason score data were collected.

68Ga-PSMA-11 PET/CT Scan

No specific patient preparation was required except bladder voiding immediately before imaging. All patients were injected intravenously with 68Ga-PSMA-11 (mean, 169.6 ± 16.5 MBq). At 60 min, a scan was acquired from pelvis to skull base at 4 min per bed position with an axial field of view of 15.7 cm and an 11-slice overlap between bed positions, using a Discovery 710 PET/CT scanner (GE Healthcare). A low-dose CT scan (140 kV; mAs, 15–100; noise index, 40; rotation time, 0.5 s; and collimation, 40 mm) was obtained at the start of imaging to provide attenuation correction and an anatomic reference. PET image reconstruction used a Bayesian penalized likelihood algorithm (Q.CLEAR; GE Healthcare) with a β penalization factor of 800 as previously described (15,16).

99Tc-MIP-1404 SPECT/CT Scan

No specific patient preparation was required except bladder voiding immediately before imaging. All patients were injected intravenously with 99mTc-MIP-1404 (mean 705 ± 61 MBq). At 2–4 h, SPECT scans were acquired on a Symbia T2 SPECT/CT system (Siemens Healthcare) from midthigh to skull vertex with low-energy high-resolution collimation, a 128 × 128 matrix with 4.8-mm pixel size, and 120 projections over 360° for 15 s per projection. SPECT scans were followed by low-dose CT (130 kV, 30 mAs) using adaptive dose modulation (CAREDose 4D; Siemens Healthcare). CT data were reconstructed with 3- and 5-mm slice thicknesses using B70s and B41s kernels for image analysis. The SPECT dataset was reconstructed using an ordered-subset expectation maximization algorithm with 4 subsets and 8 iterations, including point-spread-function modeling with CT-based attenuation correction and dual-energy window scatter correction as previously described (10). Both PET and SPECT scanners underwent routine quality control measures.

Scan Analysis

For each subject, SUVmax was measured in any malignant lesion in the prostate or prostate bed and up to 3 lesions in each of pelvic nodes (N1), extrapelvic nodes (M1a), and skeletal (M1b) and visceral metastases (M1c) using Hermes Gold software (Hermes Medical Solution). A semiquantitative expression score was measured by comparison to normal tissues including the mediastinal blood pool (MBP), liver, spleen, and parotid glands, according to the PROMISE proposed classification for PSMA ligand PET/CT interpretation (17). For the liver, a 3-cm spheric volume of interest was placed in the center of the right lobe avoiding metastases if present, with 2-cm volumes of interest used for spleen, MBP (aortic arch), and parotid glands. SUVmax was calculated for each. For each malignant lesion, a lesion-to-liver, lesion-to-spleen, lesion–to–blood-pool, and lesion–to–parotid gland ratio was calculated.

Statistical Analysis

Statistical analyses were performed using SPSS (version 27; IBM Corp). Data were tested for normality, and comparisons made with either the t test or the Mann–Whitney test and values presented as mean ± SD or median and range accordingly. A P value of < 0.05 was taken for statistical significance.

RESULTS

The 99mTc-MIP-1404 group and the 68Ga-PSMA-11 group of mCRPC patients were matched for age (median, 72 and 71 y, respectively), PSA level (mean, 413.4 and 415.6 ng/mL, respectively), and Gleason score (median, 9 and 9, respectively). The previous rates of androgen deprivation therapy and other local or systemic therapies (except prostatectomy rate) were also similar between the 2 groups (Table 1). The 2 groups showed a similar distribution of metastatic disease on either 99mTc-MIP-1404 SPECT or 68Ga-PSMA-11 PET in the prostate/prostate bed (7 and 10 patients, respectively), N1 (8 and 13 patients, respectively), M1a (8 and 9 patients, respectively), M1b (23 and 23 patients, respectively), and M1c (4 and 4 patients, respectively).

View this table:
  • View inline
  • View popup
TABLE 1.

Characteristics in 99mTc-MIP-1404 and 68Ga-PSMA-11 Groups

Lesion SUVmax measurements were not statistically different between the 2 groups (median, 18.2, range, 4.1–52.1 for the 99mTc-MIP-1404 group; and median, 17.3, range, 3.4–128 for the 68Ga-PSMA-11 group; P = 0.93). However, liver SUVmax was higher in the 99mTc-MIP-1404 scans (median, 8.5, range, 4.7–13.9 for the 99mTc-MIP-1404 group; and median, 5.8, range, 3.9–9.0 for the 68Ga-PSMA-11 group; P = 0.002) (Fig. 1A). Lesion-to-liver ratios were lower in the 99mTc-MIP-1404 group (median 2.5, range 0.6–10.5 for the 99mTc-MIP-1404 group; and median, 3.7, range, 0.8–17.1 for the 68Ga-PSMA-11 group; P = 0.009) (Fig. 1B). Lesion-to-liver ratios of 99mTc-MIP-1404 SPECT were on average 57% of those with 68Ga-PSMA-11 PET.

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

Box plots of 99mTc-MIP-1404 and 68Ga-PSMA-11 liver SUVmax (P = 0.002) (A) and lesion-to-liver SUVmax ratios (P = 0.009) (B) in patients with mCRPC. median = central line; mean = X; box = interquartile range (IQR); whiskers = maximum and minimum values; O = outliers > 1.5 IQR.

There was no significant difference in parotid gland SUVmax between the 99mTc-MIP-1404 and the 68Ga-PSMA-11 group (mean, 13.4 ± 7.1 and 16.8 ± 6.4, respectively; P = 0.23) or lesion–to–parotid gland ratios (median, 1.8, range; 0.3–6.4; and median, 1.4, range, 0.3–7.0, respectively; P = 0.5). Similarly, there was no difference between spleen SUVmax (median, 11.5, range, 5.4–22.5; and median, 9.3, range, 4.9–16.0, respectively; P = 0.072), but there was a small difference in lesion-to-spleen ratios (median, 1.4, range, 0.3–6.1; and median, 2.0, range, 0.4–14.9, respectively; P = 0.034). There was a difference between MBP SUVmax measurements (mean, 1.1 ± 0.3 and 1.6 ± 0.3, respectively; P = 0.003) and lesion- to-MBP ratios (median, 19.9, range, 3.8–114.5; and median, 13.5, range, 2.7–57.6, respectively; P = 0.011) (Table 2).

View this table:
  • View inline
  • View popup
TABLE 2.

Lesion, Normal-Organ (Liver, Spleen, Parotid Gland, MBP), and Lesion–to–Normal-Organ Ratios Between 99mTc-MIP-1404 and 68Ga-PSMA-11 mCRPC Patients

DISCUSSION

Although we have not measured a difference in lesion avidity between 99mTc-MIP-1404 SPECT and 68Ga-PSMA-11 PET PSMA ligands in patients with mCRPC, there are differences in biodistribution. In particular, liver activity and hence lesion-to-liver ratios differ between the 2 tracers with higher liver uptake but lower lesion-to-liver ratios with 99mTc-MIP-1404 SPECT. This is potentially of importance as the eligibility for 177Lu-PSMA-617 therapy in the VISION trial depended on a lesion-to-liver ratio greater than 1 using 68Ga-PSMA-11 (2,3). Another phase 2 study used a lesion-to-liver ratio of 1.5 and absence of 18F-FDG–positive and 68Ga-PSMA-11–negative lesions to determine eligibility (18).

Different eligibility criteria would therefore need to be considered for different PSMA ligands so that patients are not deemed ineligible from treatment when they may benefit if confirmation of PSMA expression at all metastatic sites is mandated by reimbursement guidelines before treatment.

Although the predominant renal excretion route of 99mTc-MIP-1404 is not dissimilar to that of 68Ga-PSMA-11 (10), there appear to be sufficient differences to provide variation in lesion-to-liver ratios between the 2 tracers. This is probably even more relevant for other PSMA ligands that have a predominant hepatobiliary route of excretion such as 18F-PSMA-1007, for which liver SUVmax has been shown to be more than double that of 68Ga-PSMA-11 in a comparative study (8). We found the mean 99mTc-MIP-1404 lesion-to-liver ratio to be 57% of that of 68Ga-PSMA-11, suggesting that a correspondingly lower lesion-to-liver ratio would be required to achieve equitable eligibility for 177Lu-PSMA-617 therapy if applying the VISION trial, or other previously reported, eligibility criteria (2,18). Although an optimal level of lesion uptake has not been defined for 177Lu-PSMA-617 efficacy, it is generally accepted that a theranostic pair is required to ensure targetable disease and to avoid futile therapy in the minority of patients with non–PSMA-expressing disease (4,11).

To standardize PSMA ligand PET reporting, it has been suggested that uptake in metastatic lesions should be graded by comparison to blood pool, liver, or parotid gland (or spleen in liver-dominant excretion ligands) (17). We have therefore measured uptake in these organs in our series. Our results compare closely with another published series of 68Ga-PSMA-11 with respect to liver, spleen, and parotid gland SUVmax measurements with a small difference in blood-pool values, possibly due to methodologic differences in measurement of the latter (6). Interestingly, the 99mTc-MIP-1404 ligand shows no significant difference from 68Ga-PSMA-11 with respect to lesion uptake, parotid gland uptake, lesion–to–parotid gland ratio, spleen, and lesion-to-MBP ratios. Apart from the previously mentioned lesion-to-liver ratio differences, lesion-to-spleen ratios and MBP SUVmax were lower for 99mTc-MIP-1404, reflecting differences in biodistribution and pharmacokinetics of the 2 PSMA ligands. We also noted higher variability in splenic and parotid gland uptake between patients for both tracers compared with liver SUVmax, suggesting these organs may be less suitable than the liver as semiquantitative comparators. Rather than using a liver threshold, other studies have used a lesion SUVmax of 20 as an eligibility criterion (19,20), and it is possible that this would present an effective alternative treatment threshold. Indeed, our data show a similar SUVmax between 99mTc-MIP-1404 and 68Ga-PSMA-11 (Table 2), but further work would be required to determine comparable lesion avidity in other PSMA tracers.

Our analysis has some limitations. First, the 2 types of PSMA scan were not performed in the same patients. Nevertheless, both the groups analyzed included patients with mCRPC who would potentially be eligible for 177Lu-PSMA-617 therapy and were reasonably well matched for age, PSA level, Gleason score, and other relevant characteristics. However, perfect matching is unlikely and a study of both scans in the same patients, or a study evaluating 68Ga-PSMA-11 uptake in 99mTc-MIP-1404–negative patients, would provide more robust data. Second, not all of the patients in our cohorts received 177Lu-PSMA-617 therapy and so we do not know if potential differences in eligibility for therapy would have had an impact on clinical outcomes. In addition, we cannot exclude systematic differences in SUV calculation between the SPECT and PET modalities, weakening a comparison of SUVmax between lesions and organs in the 2 cohorts. However, the ratios that we measured would not be significantly affected by systematic differences.

CONCLUSION

There are differences in biodistribution between 99mTc-MIP-1404 and 68Ga-PSMA-11 in patients with mCRPC who might be eligible for 177Lu-PSMA-617 therapy such that different semiquantitative criteria may need to be adopted for different ligands if lesion-to-liver ratios are the main parameter under consideration. This is likely to be even more important for PSMA ligands that are predominantly excreted via the hepatobiliary route. Prospective analysis of the optimal imaging metrics to predict treatment outcomes will be an important goal in future trials, particularly if SPECT agents that offer increased availability and access with reduced costs are used.

DISCLOSURE

Financial support was provided by the following: Cancer Research U.K. National Cancer Imaging Translational Accelerator (A27066), the Wellcome/Engineering and Physical Sciences Research Council Centre for Medical Engineering at King’s College London (WT 203148/Z/16/Z), and National Institute for Health Research Biomedical Research Centre at Guy’s & St Thomas’ Hospitals and King’s College London. No other potential conflict of interest relevant to this article was reported.

KEY POINTS

QUESTION: Can differences in PSMA imaging tracer biodistribution affect selection of patients for 177Lu-PSMA-617 therapy if lesion-to-liver ratios are used for treatment selection?

PERTINENT FINDINGS: This comparison of retrospective matched 68Ga-PSMA-11 PET and 99mTc-MIP-1404 SPECT data in 2 cohorts of 25 patients with mCRPC has shown differences in biodistribution that led to greater liver activity but lower lesion-to-liver ratios for 99mTc-MIP-1404.

IMPLICATIONS FOR PATIENT CARE: Different semiquantitative data may be required for different PSMA imaging tracers used as companion diagnostics to ensure equal eligibility for 177Lu-PSMA-617 therapy in mCRPC.

Footnotes

  • Published online Oct. 27, 2022.

  • © 2023 by the Society of Nuclear Medicine and Molecular Imaging.

Immediate Open Access: Creative Commons Attribution 4.0 International License (CC BY) allows users to share and adapt with attribution, excluding materials credited to previous publications. License: https://creativecommons.org/licenses/by/4.0/. Details: http://jnm.snmjournals.org/site/misc/permission.xhtml.

REFERENCES

  1. 1.↵
    1. Bois F,
    2. Noirot C,
    3. Dietemann S,
    4. et al
    . [68Ga]Ga-PSMA-11 in prostate cancer: a comprehensive review. Am J Nucl Med Mol Imaging. 2020;10:349–374.
    OpenUrl
  2. 2.↵
    1. Sartor O,
    2. de Bono J,
    3. Chi KN,
    4. et al
    . Lutetium-177-PSMA-617 for metastatic castration-resistant prostate cancer. N Engl J Med. 2021;385:1091–1103.
    OpenUrlCrossRefPubMed
  3. 3.↵
    1. Kuo PH,
    2. Benson T,
    3. Messmann R,
    4. Groaning M
    . Why we did what we did: PSMA-PET/CT selection criteria for the VISION Trial. J Nucl Med. 2022;63:816–818.
    OpenUrlFREE Full Text
  4. 4.↵
    1. Gafita A,
    2. Calais J,
    3. Grogan TR,
    4. et al
    . Nomograms to predict outcomes after 177Lu-PSMA therapy in men with metastatic castration-resistant prostate cancer: an international, multicentre, retrospective study. Lancet Oncol. 2021;22:1115–1125.
    OpenUrl
  5. 5.↵
    1. Goffin KE,
    2. Joniau S,
    3. Tenke P,
    4. et al
    . Phase 2 study of 99mTc-Trofolastat SPECT/CT to identify and localize prostate cancer in intermediate- and high-risk patients undergoing radical prostatectomy and extended pelvic LN dissection. J Nucl Med. 2017;58:1408–1413.
    OpenUrlAbstract/FREE Full Text
  6. 6.↵
    1. Kalshetty A,
    2. Menon B,
    3. Rakshit S,
    4. et al
    . Correlation of lesional uptake parameters and ratios with miPSMA score and estimating normal physiologic concentration: an exploratory analysis in metastatic castration-resistant prostatic carcinoma patients with 68Ga-PSMA-11 PET/CT. J Nucl Med Technol. 2021;49:235–240.
    OpenUrlAbstract/FREE Full Text
  7. 7.
    1. Peters SMB,
    2. Hofferber R,
    3. Privé BM,
    4. et al
    . [68Ga]Ga-PSMA-11 PET imaging as a predictor for absorbed doses in organs at risk and small lesions in [177Lu]Lu-PSMA-617 treatment. Eur J Nucl Med Mol Imaging. 2022;49:1101–1112.
    OpenUrl
  8. 8.↵
    1. Pattison DA,
    2. Debowski M,
    3. Gulhane B,
    4. et al
    . Prospective intra-individual blinded comparison of [18F]PSMA-1007 and [68Ga]Ga-PSMA-11 PET/CT imaging in patients with confirmed prostate cancer. Eur J Nucl Med Mol Imaging. 2022;49:763–776.
    OpenUrl
  9. 9.
    1. Metser U,
    2. Zukotynski K,
    3. Mak V,
    4. et al
    . Effect of 18F-DCFPyL PET/CT on the management of patients with recurrent prostate cancer: results of a prospective multicenter registry trial. Radiology. 2022;303:414–422.
    OpenUrl
  10. 10.↵
    1. Schmidkonz C,
    2. Hollweg C,
    3. Beck M,
    4. et al
    . 99mTc-MIP-1404-SPECT/CT for the detection of PSMA-positive lesions in 225 patients with biochemical recurrence of prostate cancer. Prostate. 2018;78:54–63.
    OpenUrl
  11. 11.↵
    1. Sheikh N,
    2. Younis MN,
    3. Mumtaz M,
    4. Shahid A
    . Tc-99m PSMA and Lu-177 PSMA theranostic pair in a patient of metastatic castration resistant prostate cancer. JPMA J Pak Med Assoc. 2021;71:2679–2682.
    OpenUrl
  12. 12.↵
    1. Hillier SM,
    2. Maresca KP,
    3. Lu G,
    4. et al
    . 99mTc-labeled small-molecule inhibitors of prostate-specific membrane antigen for molecular imaging of prostate cancer. J Nucl Med. 2013;54:1369–1376.
    OpenUrlAbstract/FREE Full Text
  13. 13.↵
    1. Vallabhajosula S,
    2. Nikolopoulou A,
    3. Babich JW,
    4. et al
    . 99mTc-labeled small-molecule inhibitors of prostate-specific membrane antigen: pharmacokinetics and biodistribution studies in healthy subjects and patients with metastatic prostate cancer. J Nucl Med. 2014;55:1791–1798.
    OpenUrlAbstract/FREE Full Text
  14. 14.↵
    1. Sandgren K,
    2. Johansson L,
    3. Axelsson J,
    4. et al
    . Radiation dosimetry of [68Ga]PSMA-11 in low-risk prostate cancer patients. EJNMMI Phys. 2019;6:2.
    OpenUrl
  15. 15.↵
    1. Chuah SJ,
    2. Kulkarni M,
    3. Pike L,
    4. et al
    . Bayesian penalised likelihood (‘Q-clear’) reconstruction of 68Ga-THP-PSMA PET/CT in prostate cancer: a comparison with standard image reconstruction methods. Nucl Med Commun. 2019;40:416–417.
    OpenUrl
  16. 16.↵
    1. Krokos G,
    2. Pike LC,
    3. Cook GJR,
    4. Marsden PK
    . Standardisation of conventional and advanced iterative reconstruction methods for gallium-68 multi-centre PET-CT trials. EJNMMI Phys. 2021;8:52.
    OpenUrl
  17. 17.↵
    1. Eiber M,
    2. Herrmann K,
    3. Calais J,
    4. et al
    . Prostate cancer molecular imaging standardized evaluation (PROMISE): proposed miTNM classification for the interpretation of PSMA-ligand PET/CT. J Nucl Med. 2018;59:469–478.
    OpenUrlAbstract/FREE Full Text
  18. 18.↵
    1. Hofman MS,
    2. Violet J,
    3. Hicks RJ,
    4. et al
    . [177Lu]-PSMA-617 radionuclide treatment in patients with metastatic castration-resistant prostate cancer (LuPSMA trial): a single-centre, single-arm, phase 2 study. Lancet Oncol. 2018;19:825–833.
    OpenUrlCrossRefPubMed
  19. 19.↵
    1. Hofman MS,
    2. Emmett L,
    3. Violet J,
    4. et al
    . ANZUP TheraP team, Davis ID. TheraP: a randomized phase 2 trial of 177 Lu-PSMA-617 theranostic treatment vs cabazitaxel in progressive metastatic castration-resistant prostate cancer (Clinical Trial Protocol ANZUP 1603). BJU Int. 2019;124(suppl 1):5–13.
    OpenUrlCrossRef
  20. 20.↵
    1. Dhiantravan N,
    2. Emmett L,
    3. Joshua AM,
    4. et al
    . UpFrontPSMA: a randomized phase 2 study of sequential 177 Lu-PSMA-617 and docetaxel vs docetaxel in metastatic hormone-naïve prostate cancer (clinical trial protocol). BJU Int. 2021;128:331–342.
    OpenUrl
  • Received for publication May 20, 2022.
  • Revision received August 11, 2022.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 64 (2)
Journal of Nuclear Medicine
Vol. 64, Issue 2
February 1, 2023
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
  • Complete Issue (PDF)
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Eligibility for 177Lu-PSMA Therapy Depends on the Choice of Companion Diagnostic Tracer: A Comparison of 68Ga-PSMA-11 and 99mTc-MIP-1404 in Metastatic Castration-Resistant Prostate Cancer
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Eligibility for 177Lu-PSMA Therapy Depends on the Choice of Companion Diagnostic Tracer: A Comparison of 68Ga-PSMA-11 and 99mTc-MIP-1404 in Metastatic Castration-Resistant Prostate Cancer
Gary J.R. Cook, Wai-Lup Wong, Bal Sanghera, Stephen Mangar, Amarnath Challapalli, Amit Bahl, Paul Bassett, Darren Leaning, Christian Schmidkonz
Journal of Nuclear Medicine Feb 2023, 64 (2) 227-231; DOI: 10.2967/jnumed.122.264296

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Eligibility for 177Lu-PSMA Therapy Depends on the Choice of Companion Diagnostic Tracer: A Comparison of 68Ga-PSMA-11 and 99mTc-MIP-1404 in Metastatic Castration-Resistant Prostate Cancer
Gary J.R. Cook, Wai-Lup Wong, Bal Sanghera, Stephen Mangar, Amarnath Challapalli, Amit Bahl, Paul Bassett, Darren Leaning, Christian Schmidkonz
Journal of Nuclear Medicine Feb 2023, 64 (2) 227-231; DOI: 10.2967/jnumed.122.264296
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Visual Abstract
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Predicting Outcomes of Indeterminate Bone Lesions on 18F-DCFPyL PSMA PET/CT Scans in the Setting of High-Risk Primary or Recurrent Prostate Cancer
  • PSMA-Directed Imaging and Therapy of Salivary Gland Tumors: A Single-Center Retrospective Study
  • 177Lu-PSMA SPECT Quantitation at 6 Weeks (Dose 2) Predicts Short Progression-Free Survival for Patients Undergoing 177Lu-PSMA-I&T Therapy
Show more Clinical Investigation

Similar Articles

Keywords

  • 177Lu-PSMA-617
  • 68Ga-PSMA-11
  • 99mTc-MIP-1404
SNMMI

© 2023 Journal of Nuclear Medicine

Powered by HighWire