Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Continuing Education
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Continuing Education
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportImage Generation

DuDoSS: Deep-Learning-Based Dual-Domain Sinogram Synthesis from Sparsely Sampled Projections of Cardiac SPECT

Xiongchao Chen, Bo Zhou, Huidong Xie, Tianshun Miao, Edward Miller, Sinusas Albert and Chi Liu
Journal of Nuclear Medicine June 2022, 63 (supplement 2) 2519;
Xiongchao Chen
1Yale University
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Bo Zhou
1Yale University
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Huidong Xie
1Yale University
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Tianshun Miao
1Yale University
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Edward Miller
1Yale University
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Sinusas Albert
2Yale University School of Medicine
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Chi Liu
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
Loading

Abstract

2519

Introduction: Myocardial perfusion imaging (MPI) using single-photon emission computed tomography (SPECT) is widely applied for the diagnosis of cardiovascular diseases. In clinical practice, the tedious scanning procedures and long acquisition time might increase patient anxiety and discomfort, motion artifacts, misalignments of SPECT and computed tomography (CT). Reducing the number of projection angles is a feasible solution to reduce the scanning time. However, fewer projection angles might cause lower reconstruction accuracy, higher noise level, and reconstruction artifacts. We developed a deep learning-based approach to improve image quality reconstructed from sparsely sampled projections.

Methods: We propose a novel deep-learning-based dual-domain sinogram synthesis (DuDoSS) to recover the full-view projections from sparsely sample projections of cardiac SPECT images. The studying dataset includes a total of 500 anonymized clinical stress-state MPI studies acquired on a GE NM/CT 850c scanner with 60 projection angles. One-day stress-only low-dose protocol, with the mean administered dose of 15 mCi 99mTc-tetrofosmin, was used. DuDoSS applies the SPECT images predicted in the image domain as guidance for the synthesis of the full-view projections in the sinogram domain. The SPECT image reconstructed using sparsely sampled projections is first input to an image-domain neural network in the image domain to predict the SPECT image reconstructed using ground-truth full-view projections. The predicted SPECT image is then forward-projected to generate pseudo full-view projections, which are then input to another projection-domain neural network to predict the ground-truth full-view projections. The synthetic projections were then reconstructed into non-attenuation-corrected (NAC) and attenuation-corrected (AC) SPECT images with or without CT-derived attenuation maps for quantitative evaluations. Voxel-wise evaluation metrics including normalized mean square error (NMSE) and segment-wise evaluation metrics including absolute percent error (APE) are applied for the quantitative evaluations. Several testing groups are setup for comparison. CUSIP refers to a recently proposed approach, Convolutional U-Net-shaped Synthetic Intermediate Projections. CUSIP-DuRDN refers to the CUSIP method using a recently proposed deep learning algorithm Dual Squeeze-and-excitation Residual Dense Network (DuRDN). Direct Sino2Sino refers to predicting synthetic projections from zero-padded sparse-view projections directly. Direct Img2Img refers to predicting the full-view SPECT images from sparse-view SPECT images directly.

Results: Our proposed DuDoSS generated more accurate synthetic projections than CUSIP (NMSE 2.08 ± 0.81% versus 2.84 ± 0.97%, p < 0.001). The reconstructed images of DuDoSS are more accurate than CUSIP for both NAC (NMSE 1.89 ± 0.79% versus 3.02 ± 1.10%, p < 0.001) and AC images (NMSE 1.63 ± 0.72% versus 2.70 ± 0.94%, p < 0.001). In addition, the APE of the 17-segment polar maps of DuDoSS is significantly lower than CUSIP (APE 3.92 ± 3.20 % versus 12.23 ± 4.46%, p < 0.001).

Conclusions: Our proposed DuDoSS can generate accurate synthetic full-view projections from sparsely acquired projections for cardiac SPECT MPI. The synthetic projections generated by our DuDoSS are more accurate than the previous CUSIP approach. Besides, the reconstructed NAC and AC images using the synthetic projections by DuDoSS show lower errors than those of CUSIP.

KEYWORDS: deep learning, sinogram synthesis, cardiac SPECT, myocardial perfusion imaging

Figure
  • Download figure
  • Open in new tab
  • Download powerpoint
Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 63, Issue supplement 2
June 1, 2022
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
DuDoSS: Deep-Learning-Based Dual-Domain Sinogram Synthesis from Sparsely Sampled Projections of Cardiac SPECT
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
DuDoSS: Deep-Learning-Based Dual-Domain Sinogram Synthesis from Sparsely Sampled Projections of Cardiac SPECT
Xiongchao Chen, Bo Zhou, Huidong Xie, Tianshun Miao, Edward Miller, Sinusas Albert, Chi Liu
Journal of Nuclear Medicine Jun 2022, 63 (supplement 2) 2519;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
DuDoSS: Deep-Learning-Based Dual-Domain Sinogram Synthesis from Sparsely Sampled Projections of Cardiac SPECT
Xiongchao Chen, Bo Zhou, Huidong Xie, Tianshun Miao, Edward Miller, Sinusas Albert, Chi Liu
Journal of Nuclear Medicine Jun 2022, 63 (supplement 2) 2519;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Figures & Data
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Data-driven gated (DDG) CT: An automated respiratory gating method to enable DDG PET/CT
  • Evaluation of MR-guided PET reconstruction using parallel level sets in epileptogenic zone identification
  • Variability in quantification between SPECT/CT scanners with a low-count quantitative SPECT method for alpha-particle radiopharmaceutical therapies
Show more Image Generation

Similar Articles

SNMMI

© 2023 Journal of Nuclear Medicine

Powered by HighWire