Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Permissions
    • Advertisers
    • Continuing Education
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Permissions
    • Advertisers
    • Continuing Education
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Follow JNM on Twitter
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Subscribe to our RSS feeds
Meeting ReportPhysics, Instrumentation & Data Sciences

Motion Correction for Simultaneous PET/MR Brain Imaging Using a Radiofrequency-Penetrable PET Insert.

Jonathan Fisher, Andrew Groll and Craig Levin
Journal of Nuclear Medicine May 2020, 61 (supplement 1) 367;
Jonathan Fisher
1Stanford University Stanford CA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Andrew Groll
1Stanford University Stanford CA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Craig Levin
2Stanford Stanford CA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
Loading

Abstract

367

Introduction: Subject motion during PET/MR scans reduces image quality and accuracy. In this paper, a motion correction (MC) solution, and experimental results, demonstrating the solution’s performance on a three-point-sources motion phantom, are presented. Our camera-based solution tracks the motion of a marker attached to an object to be imaged, translates the motion measured by the camera to motion in the scanner coordinate system, and incorporates that motion data into the image reconstruction algorithm. The experimental data was acquired by the radiofrequency-penetrable brain dedicated PET insert for simultaneous PET/MR [1-3].

Methods: MR Compatible PET insert - The RF-penetrable PET system comprises a ring of 16 detector modules. These modules employ arrays of 3.2 x 3.2 x 20 mm3 LYSO crystal elements 1-1 coupled to arrays of silicon photomultipliers (SiPM). Each module has 128 crystals which provides a 3 cm crystal axial FOV for this prototype system. The RF-penetrable PET ring has a 32-cm internal diameter (an addition phased array RF receive coil reduces the effective diameter to 28 cm) design to be inserted into a 3T MR system - fig.1. Camera-based rigid body motion tracking - A 2.0 Megapixel web camera with 1/2.7" CMOS OV2710 image sensor. The camera was located 9-11 cm away from the marker, outside the bore. The camera-based motion tracking approach includes an initial camera calibration step (to correct for the camera’s distortion). Then, for every frame, the marker’s pose, Tmc (rotation and translation) was estimated (with respect to the camera’s coordinate system, as suggested in [4-6] and implemented using “camera calibration and 3D vision” MATLAB toolbox). Knowing the poses at times 0 and t, the relative change in pose estimation is defined as [7]: Tmtmo = Tcmo Tmtc = (Tmoc )-1Tmtc. Camera-to-scanner Cross-calibration - Knowing the camera-to-scanner coordinate systems transformation, it was possible to translate the motion being recorded in the camera coordinate system to motion in the scanner coordinate system. The Tsai-Lenz hand-eye calibration [8] was performed to do so. A 2D checkerboard marker and three point sources (500, 500, and 100 μCi) were mounted to a 3D printed a motion sphere - fig.2. The sphere’s pose was changed ten times. For each pose, a picture of the marker was taken, and 10 minutes of PET data was acquired. The data were energy windowed from 410 - 610 keV with a 10 ns time window. Images were generated using GPU accelerated 3D-OSEM reconstruction with a total of 5 iterations with one sub iteration per iteration [10]. System sensitivity normalization was assessed separately from an annulus-based normalization study which was acquired over 7 hours with an initial activity of 3.52 mCi of FDG. The 10 samples were randomly divided, 6 samples were used to estimate the cross-calibration and the rest of the samples were used to evaluate the solution’s performance. MAF reconstructed image - The multiple acquisition frames (MAF) correction method [9] for MC was implemented on the 4 remaining images. Knowing the relative motion between frames, and the Camera-to-scanner Cross-calibration, we knew how to correct for motion between frames and align the reconstructed images.

Results: Reconstructed images of a single frame and multiple frames with and without MC are presented in fig.3-5. The MC image (fig. 5.) is almost identical to the single frame image (fig. 3.).

Conclusions: This study demonstrated the ability of our camera-based MC solution to compensate for phantom motion. The same approach can be generalized and used on more complicated phantoms and on patients. Acknowledgment: This work was supported in part by NIH grants 3R01EB01946504 and 3R01EB01946504S1.

Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 61, Issue supplement 1
May 1, 2020
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Motion Correction for Simultaneous PET/MR Brain Imaging Using a Radiofrequency-Penetrable PET Insert.
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Motion Correction for Simultaneous PET/MR Brain Imaging Using a Radiofrequency-Penetrable PET Insert.
Jonathan Fisher, Andrew Groll, Craig Levin
Journal of Nuclear Medicine May 2020, 61 (supplement 1) 367;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Motion Correction for Simultaneous PET/MR Brain Imaging Using a Radiofrequency-Penetrable PET Insert.
Jonathan Fisher, Andrew Groll, Craig Levin
Journal of Nuclear Medicine May 2020, 61 (supplement 1) 367;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Physics, Instrumentation & Data Sciences

  • AI-based methods for nuclear-medicine imaging: Need for objective task-specific evaluation
  • Ultra-Fast Reconstruction of Short List-Mode PET Data Frames for Real-Time Visualization and Processing
  • Keel-Edge Height Selection for Improved Multi-Pinhole 123I Brain SPECT Imaging
Show more Physics, Instrumentation & Data Sciences

Motion Correction PET

  • Adaptive data-driven motion detection for optimized motion correction of brain PET
  • Low dose brain PET imaging enabled by marker-based tracking of head motion and list mode reconstruction.
Show more Motion Correction PET

Similar Articles

SNMMI

© 2023 Journal of Nuclear Medicine

Powered by HighWire