Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Continuing Education
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Continuing Education
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Follow JNM on Twitter
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Subscribe to our RSS feeds
Meeting ReportPhysics, Instrumentation & Data Sciences

Significance of Rotational Correction on Renal Dynamic Imaging

Lei Zhang, Zhifang Wu, Jidi Xue, Jiafu Peng, Sijin Li and Hua Wei
Journal of Nuclear Medicine May 2020, 61 (supplement 1) 325;
Lei Zhang
1Department of Nuclear Medicine, the First Hospital of Shanxi Medical University Taiyuan China
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Zhifang Wu
1Department of Nuclear Medicine, the First Hospital of Shanxi Medical University Taiyuan China
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jidi Xue
1Department of Nuclear Medicine, the First Hospital of Shanxi Medical University Taiyuan China
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jiafu Peng
1Department of Nuclear Medicine, the First Hospital of Shanxi Medical University Taiyuan China
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Sijin Li
2First Hospital of Shanxi Medical University Taiyuan China
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Hua Wei
3First Hospital of Shanxi Medical University Taiiyuan China
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
Loading

Abstract

325

Objectives: To investigate the effect of the depth and depth difference of two kidneys measured by the rotation method on the measurement of total and fractional GFR by Gates method and its significance on renal dynamic imaging.

Methods: A total of 57 patients undergoing renal dynamic imaging and abdominal CT in our hospital were reviewed retrospectively. The depth and depth difference between the two kidneys were measured by CT, rotation(Figure 1), Tonnesen and Lee formula, and substituted into the Gates formula to obtain total kidney and divided kidney GFR. The values measured by CT were taken as the standard, the paired t-test was used to analyze the differences between the values measured by rotation, Tonnesen and Lee formula with CT. Bland-Altman test was used for consistency analysis. Pearson correlation analysis was performed on the difference in depth and the resulting changes in divided renal function.

Results: Compared with CT: ①Tonnesen formula underestimated the total kidney and divided kidney GFR, with statistically significant differences (total kidney: 61.84±22.13vs77.11±27.52, left kidney: 28.52±12.87vs35.93±15.92, right kidney: 33.32±13.82vs41.18±16.91; P< 0.05); There was no significant difference in the GFR of total kidney and divided kidney measured by Lee formula and rotation(total kidney: 78.24±26.86 76.62±27.02vs77.11±27.52, left kidney: 36.24±15.85 35.64±15.87vs35.93±15.92, right kidney: 41.99±16.99 40.98±17.25vs41.18±16.91; P> 0.05), and the consistency was good. Among them, the bias measured by rotation was the smallest. ②Tonnesen formula underestimated the depth of both kidneys, with statistically significant differences (left kidney: 5.97±0.89vs7.31±1.26, right kidney: 6.01±0.90vs7.28±1.16; P< 0.05); There was no significant difference in the depth of the two kidneys measured by Lee formula and rotation (left kidney: 7.40±1.18 7.26±1.28vs7.31±1.26, right kidney: 7.40±1.10 7.23±1.18vs7.28±1.16; P> 0.05), and the consistency was good. Among them, the bias measured by rotation was the smallest. ③Tonnesen and Lee formula underestimated the difference between the two kidney depths, and the difference was statistically significant (0.04±0.01 0.07±0.05vs0.41±0.33; P<0.05). There was no significant difference in the difference between the two kidney depths measured by rotation (0.48±0.36vs0.41±0.33, P>0.05).(Table 1) ④The depth difference was positively related to the changes in divided renal function (|R(CT) -R (Lee)|) and (|R(Rotation) -R(Lee)|) (R=0.967, 0.702, P<0.05)(Figure 2).As the depth difference increases, it is difficult for Lee formula to precisely show changes in divided renal function.

Conclusions: The accurate depth and depth difference of the two kidneys can be obtained by rotation method, so as to improve the accuracy of GFR measurement by Gates method.

Figure
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure
  • Download figure
  • Open in new tab
  • Download powerpoint
View this table:
  • View inline
  • View popup

Depth, depth difference and GFR value of two kidneys measured by four methods (x ± s)

Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 61, Issue supplement 1
May 1, 2020
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Significance of Rotational Correction on Renal Dynamic Imaging
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Significance of Rotational Correction on Renal Dynamic Imaging
Lei Zhang, Zhifang Wu, Jidi Xue, Jiafu Peng, Sijin Li, Hua Wei
Journal of Nuclear Medicine May 2020, 61 (supplement 1) 325;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Significance of Rotational Correction on Renal Dynamic Imaging
Lei Zhang, Zhifang Wu, Jidi Xue, Jiafu Peng, Sijin Li, Hua Wei
Journal of Nuclear Medicine May 2020, 61 (supplement 1) 325;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Figures & Data
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Physics, Instrumentation & Data Sciences

  • 3D Structural Convolutional Sparse Coding for PET Image Reconstruction
  • Exploration of Multi-objective Optimization with Genetic Algorithms for PET Image Reconstruction
  • AI-based methods for nuclear-medicine imaging: Need for objective task-specific evaluation
Show more Physics, Instrumentation & Data Sciences

Instrumentation - Clinical imaging and optimization

  • Dynamic range of the newest digital PET-CT scanner for myocardial blood flow quantification using Rubidium-82
  • Improved Sentinel Node Localization in Patients with Newly Diagnosed Melanoma Utilizing a Fully Digital CZT SPECT/CT System Versus a Conventional NaI SPECT/CT System.
Show more Instrumentation - Clinical imaging and optimization

Similar Articles

SNMMI

© 2023 Journal of Nuclear Medicine

Powered by HighWire