Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Permissions
    • Advertisers
    • Continuing Education
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Permissions
    • Advertisers
    • Continuing Education
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Follow JNM on Twitter
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Subscribe to our RSS feeds
Meeting Report

Bolus Injection Technique for uEXPLORER 18F-FDG PET/CT Dynamic Scans

Kristin McBride, Heather Hunt, Michael Rusnak and Mike Nguyen
Journal of Nuclear Medicine May 2020, 61 (supplement 1) 3084;
Kristin McBride
1UC Davis Medical Center Sacramento CA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Heather Hunt
1UC Davis Medical Center Sacramento CA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Michael Rusnak
1UC Davis Medical Center Sacramento CA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Mike Nguyen
1UC Davis Medical Center Sacramento CA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
Loading

Abstract

3084

Objectives: To determine the best radiotracer bolus injection technique for total-body dynamic-imaging on the uEXPLORER PET/CT. This technique may prove beneficial for other molecular imaging studies currently using bolus injection techniques. uEXPLORER PET/CT is the world’s first total-body scanner capable of simultaneously capturing radiotracer bolus injection and distribution throughout the entire body in real-time.

Methods: Seven healthy subjects were scanned on the uEXPLORER PET/CT after giving informed consent. All subjects were positioned for a 60-minute dynamic scan with arms down. A small-bore 1.5cc extension tube was primed with saline and attached to an upper extremity IV. A 3-way Luer valve connected to a 10cc saline flush and approximately 0.5mCi F18-FDG radiotracer was attached to the extension tubing. Two different bolus methods were used on the 7 subjects. Method 1: Prior to imaging, pre-load the radiotracer into the extension tubing, ensuring the volume is less than 1.5cc. The radiotracer syringe is then backflushed and loaded with normal saline. With the 3-way Luer valve “off” to the saline flush, begin the PET acquisition and inject the backflushed radiotracer syringe to the patient. Immediately turn the 3-way Luer valve “off” to the radiotracer syringe and inject the remaining 10cc saline flush to the patient. Method 2: with the 3-way Luer valve turned so that all 3 connections are open, begin the PET acquisition and inject the radiotracer syringe to the patient. Immediately inject the remaining 10cc saline to the patient without adjusting the Luer valve. The SUVmax within the extension tubing/IV was collected using a 4-minute reconstruction from 1-5 minutes post injection for all 7 subjects. After collecting this patient data, both methods were tested using blue-tinged saline in place of the radiotracer to visually determine efficiency and concentration of the bolus within the tubing.

Results: Five subjects were injected using Method 1, with an SUVmax of 14.4, 7.99, 0.41, 13.15, and 1.76 respectively. Two subjects were injected using Method 2, with an SUVmax of 176 and 323 respectively. Both Method 1 and Method 2 were each tested twice using the blue-tinged saline. Both tests for Method 1 had a highly concentrated dose analog at the beginning of the bolus, with the extension tubing visually clear of dye after a 2-3cc flush of 100% normal saline. Both tests for Method 2 had a diluted concentration of the dose analog over the entire duration of the bolus, with visual dye still left in the extension tubing after 10cc normal saline flush. Blue dye (dose analog) was also observed contaminating the 100% normal saline flush syringe.

Conclusions: Subjects injected using Method 1 had an average SUVmax of 7.54, while Method 2 produced an average SUVmax of 249.5 (33 fold higher than Method 1). It is evident using a blue dye dose analog that Method 1 produces a more concentrated and efficient bolus with minimal residual within the extension tubing. Due to Method 2 allowing complete and open flow from radiotracer to the saline flush, this method has a high chance of diluting the radiotracer bolus and leaving residual radiotracer in the extension tubing and saline flush.

Figure
  • Download figure
  • Open in new tab
  • Download powerpoint
Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 61, Issue supplement 1
May 1, 2020
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Bolus Injection Technique for uEXPLORER 18F-FDG PET/CT Dynamic Scans
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Bolus Injection Technique for uEXPLORER 18F-FDG PET/CT Dynamic Scans
Kristin McBride, Heather Hunt, Michael Rusnak, Mike Nguyen
Journal of Nuclear Medicine May 2020, 61 (supplement 1) 3084;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Bolus Injection Technique for uEXPLORER 18F-FDG PET/CT Dynamic Scans
Kristin McBride, Heather Hunt, Michael Rusnak, Mike Nguyen
Journal of Nuclear Medicine May 2020, 61 (supplement 1) 3084;
del.icio.us logo Digg logo Reddit logo Twitter logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Figures & Data
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • Total-Body Quantitative Parametric Imaging of Early Kinetics of 18F-FDG
  • Google Scholar

More in this TOC Section

  • Fluselenamyl: Evaluation of radiation dosimetry in mice and pharmacokinetics in brains of non-human primate
  • SUV measurements from images reconstructed with the block sequential regularized expectation maximization algorithm: comparison of motion corrected vs. non-motion corrected data
  • Canine PET/CT imaging with 64Cu-nanomedicines
Show more

Technologist Poster Session

  • Assessment of Cardiac Amyloidosis with99mTc-Pyrophosphate (PYP) Quantitative SPECT
  • Effects of image matrix on quantitative metrics in 68Ga DOTATATE studies: Changes in SUV and signal-to-noise ratio in modern digital PET detectors
  • Changing methods of education under a pandemic - questionnaire survey about nuclear medicine examination classes at educational institutions -
Show more Technologist Poster Session

Similar Articles

SNMMI

© 2022 Journal of Nuclear Medicine

Powered by HighWire