Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Permissions
    • Advertisers
    • Continuing Education
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Permissions
    • Advertisers
    • Continuing Education
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Follow JNM on Twitter
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Subscribe to our RSS feeds
Meeting ReportCardiovascular

CT-Less Attenuation Correction in Image Space Using Deep Learningfor Dedicated Cardiac SPECT: A Feasibility Study

Jaewon Yang, Luyao Shi, Rui Wang, Chi Liu, Grant Gullberg and Youngho Seo
Journal of Nuclear Medicine May 2020, 61 (supplement 1) 223;
Jaewon Yang
1UCSF Radiology and Biomedical Imaging San Francisco CA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Luyao Shi
2Yale University PET center New Haven CT United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Rui Wang
3Radiology and Biomedical Imaging Yale University New Haven CT United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Chi Liu
4Yale University New Haven CT United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Grant Gullberg
5University of California, San Francisco El Cerrito CA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Youngho Seo
6University of California, San Francisco San Francisco CA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
Loading

Abstract

223

Introduction: Dedicated cardiac SPECT scanners (e.g., GE Discovery NM 530c) with cadmium-zinc-telluride (CZT) cameras have shown capabilities of shortened scan times or reduced radiation doses as well as improved image quality. Since most of the dedicated scanners do not have an integrated CT, image quantification with attenuation correction (AC) is challenging and artifacts are routinely encountered in daily clinical practice. In this work, we demonstrate a CT-less attenuation correction technique using deep learning (DL) for dedicated cardiac SPECT.

Methods: In an IRB-approved study, 100 cardiac SPECT/CT datasets with 99mTc-Tetrofosmin using a GE Discovery NM 570c SPECT/CT scanner were retrospectively collected at the Yale New Haven Hospital. A U-Net-based network was used for generating attenuation-corrected SPECT (SPECTDL) directly from non-corrected SPECT (SPECTNC) without undergoing an additional image reconstruction step. Quality of the DL-generated images (SPECTDL) was evaluated by the normalized root mean square error (NRMSE), peak signal to noise ratio (PSNR), and structural similarity index (SSIM). Statistical analyses were performed using joint and error histograms, demonstrating voxel-wise correlation between SPECTDL and SPECTCTAC (SPECT with CT-based AC). The clinical value of this DL-based CT-less AC was illustrated through comparison of polar bull’s eye plots.

Results: In comparison to reference SPECTCTAC, NRMSEs were 0.232 ± 0.077 and 0.148 ± 0.095; PSNRs 31.3 ± 2.8 and 36.2 ± 4.1; SSIMs 0.984 ± 0.008 and 0.993 ± 0.006 for SPECTNC and SPECTDL, respectively. These results were consistent with the joint histograms that showed the voxel-wise correlations of 92.2% ± 3.7 (slope = 0.87; R2 = 0.81) for SPECTNC and 97.7% ± 1.8 (slope = 0.94; R2 = 0.91) for SPECTDL, which was consistent with the comparison of their error histograms. Review of polar bull’s eye plots revealed successful demonstration of reduced attenuation artifacts; however, the performance of SPECTDL was not consistent for all subjects likely because of patient-specific acquisition geometries and uptake patterns.

Conclusions: This study demonstrated the feasibility of CT-less AC using deep learning for potential clinical applications in dedicated cardiac SPECT not combined with CT. Furthermore, the results showed that CT-less AC could provide similar quantification accuracy as compared to the conventional CTAC for dedicated cardiac SPECT imaging. Acknowledgements: The study was supported by the National Institutes of Health under grants R01HL135490, R01EB026331, R01HL123949, and American Heart Association award 18PRE33990138.

Figure
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure
  • Download figure
  • Open in new tab
  • Download powerpoint
Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 61, Issue supplement 1
May 1, 2020
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
CT-Less Attenuation Correction in Image Space Using Deep Learningfor Dedicated Cardiac SPECT: A Feasibility Study
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
CT-Less Attenuation Correction in Image Space Using Deep Learningfor Dedicated Cardiac SPECT: A Feasibility Study
Jaewon Yang, Luyao Shi, Rui Wang, Chi Liu, Grant Gullberg, Youngho Seo
Journal of Nuclear Medicine May 2020, 61 (supplement 1) 223;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
CT-Less Attenuation Correction in Image Space Using Deep Learningfor Dedicated Cardiac SPECT: A Feasibility Study
Jaewon Yang, Luyao Shi, Rui Wang, Chi Liu, Grant Gullberg, Youngho Seo
Journal of Nuclear Medicine May 2020, 61 (supplement 1) 223;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Figures & Data
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Cardiovascular

  • Cardiac β-Adrenergic Receptor Downregulation, Evaluated by Cardiac PET, in Chronotropic Incompetence
  • Diagnostic Performance of PET Versus SPECT Myocardial Perfusion Imaging in Patients with Smaller Left Ventricles: A Substudy of the 18F-Flurpiridaz Phase III Clinical Trial
  • Quantification of Macrophage-Driven Inflammation During Myocardial Infarction with 18F-LW223, a Novel TSPO Radiotracer with Binding Independent of the rs6971 Human Polymorphism
Show more Cardiovascular

New Techniques and Tracers for Ischemic Heart Disease (Basic Science, Cardio)

  • In vitro characterization of a novel PET tracer for fatty acid oxidation, 18F-AS3504073-00
  • NOVEL METHODOLGY FOR MEASURING REGIONAL MYOCARDIAL EFFICIENCY
Show more New Techniques and Tracers for Ischemic Heart Disease (Basic Science, Cardio)

Similar Articles

SNMMI

© 2023 Journal of Nuclear Medicine

Powered by HighWire