Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Permissions
    • Advertisers
    • Continuing Education
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Permissions
    • Advertisers
    • Continuing Education
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Follow JNM on Twitter
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Subscribe to our RSS feeds
Meeting Report

Tutorial for optimal utilization of SNMMI fully automated cloud-based PET Phantom Analysis Tool for PET/CT Quality Control

John Sunderland and Bonnie Clarke
Journal of Nuclear Medicine May 2020, 61 (supplement 1) 1195;
John Sunderland
1University of Iowa Iowa City IA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Bonnie Clarke
2Society of Nuclear Medicine and Molecular Imaging Mc Lean VA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
Loading

Abstract

1195

Objectives: Recently, the SNMMI launched a fully-automated cloud-based phantom analysis tool (PAT) at http://www.snmmi.org/PAT, available freely to dues-paying members of SNMMI. Phantom analysis modules are available for the ACR PET phantom, the standard 30cm cylindrical PET uniform phantom, The NEMA Image Quality phantom, and the CTN oncology phantom. The primary purpose of the tool is to facilitate enhancement of scanner quality control programs by providing easy-to-use, robust, and reproducible quantitative tools to measure and document scanner performance. The primary objectives of this exhibit are to 1) provide a visual tutorial of how to access and use the software, 2) present phantom imaging protocols and describe image upload and analysis procedures 3) describe the quantitative measurements provided for each phantom, 4) review the report options.

Methods: First, accessing the cloud-based software and the generation of an individual username and password for PAT are described. Available instructional material describing the phantom program and how to use the software and understand the results are presented. Second, detailed descriptions of phantom fill and acquisition instructions are presented for each phantom. One of the primary purposes of the analysis software to meet the needs of technologists and physicists generating data to fulfill PET/CT scanner accreditation requirements (i.e., ACR, Joint Commission). Fill and acquisition instructions are provided to optimally meet these needs. Alternative fill and acquisition combinations are described for use with other non-accreditation use-cases (i.e., low contrast lesion detectability, image quality, reconstruction optimization⋯). Image upload, radioactivity fill data input, and analysis initiation are described. Third, the quantitative output of each phantom analysis is described. Depending upon the phantom, reported results include calibration accuracy, noise, axial and radial clinical reconstructed resolution, recovery coefficient curves, or axial and radial uniformity. The methods used to generate each of the metrics from the image data are presented to provide background and context to the reports. Lesion detectability and low contrast resolution are two assessments necessary for Joint Commission accreditation and require expert reader interpretations, rather than automated analysis. A formalism using Likert scales for consistent reporting of these metrics are presented.

Results: Fourth, available downloadable phantom analysis reports are described for each of the phantoms. PDF documents are generated with phantom-specific measurements, plots and screen shots of representative reconstructed slices. These are designed to present necessary information to meet accreditation requirements. An Excel spreadsheet is also generated for each phantom analysis, with a summary quantitative analysis. Finally, a Java script Object Notation (.json) file generated for all analyses is described. This file contains all data used in the analyses, including relevant DICOM header information, phantom fill data, feature coordinates, and quantitative image data calculations. Conclusion: Instructions for use of a fully automated, cloud-based, publicly available PET/CT phantom analysis tool is described. The primary purpose of the tool is to support more robust PET/CT scanner quality control programs and facilitate compliance with national accreditation programs.

Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 61, Issue supplement 1
May 1, 2020
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Tutorial for optimal utilization of SNMMI fully automated cloud-based PET Phantom Analysis Tool for PET/CT Quality Control
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Tutorial for optimal utilization of SNMMI fully automated cloud-based PET Phantom Analysis Tool for PET/CT Quality Control
John Sunderland, Bonnie Clarke
Journal of Nuclear Medicine May 2020, 61 (supplement 1) 1195;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Tutorial for optimal utilization of SNMMI fully automated cloud-based PET Phantom Analysis Tool for PET/CT Quality Control
John Sunderland, Bonnie Clarke
Journal of Nuclear Medicine May 2020, 61 (supplement 1) 1195;
del.icio.us logo Digg logo Reddit logo Twitter logo CiteULike logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Comparison of pulmonary perfusion index using99mTc-MAA SPECTand evaluation indices obtained from right-sided heart catheterization in chronic thromboembolic pulmonary hypertension
  • Bolus Injection Technique for uEXPLORER 18F-FDG PET/CT Dynamic Scans
  • Possibility of Shortening Examination Time in Amyloid PET using 18F-Flutemetamol
Show more

Oncology Poster Session (Educational Exhbits)

  • PET Manifestations of Adverse Events to Immunotherapy Agents
  • Revisiting physiological FDG uptake throughout SiPM-based PET/CT scanner
  • Simplified Dosimetry Methods in Thyroid Cancer: An Overview of Methods that Can Be Implemented in Clinical Practice for Treatment Planning with I-131
Show more Oncology Poster Session (Educational Exhbits)

Similar Articles

SNMMI

© 2023 Journal of Nuclear Medicine

Powered by HighWire