Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Permissions
    • Advertisers
    • Continuing Education
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Permissions
    • Advertisers
    • Continuing Education
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Follow JNM on Twitter
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Subscribe to our RSS feeds
Meeting ReportCardiovascular

Injection-to-scan delay correction improves scan-rescan reproducibility sodium fluoride (18F-NaF) coronary plaque imaging.

Martin Lyngby Lassen, Jacek Kwiecinski, Damini Dey, Sebastien Cadet, Guido Germano, Daniel Berman, Philip Adamson, Alastair Moss, Marc Dweck, David Newby and Piotr Slomka
Journal of Nuclear Medicine May 2019, 60 (supplement 1) 451;
Martin Lyngby Lassen
2Cedars-Sinai Medical Center Los Angeles CA United States
3Cedars-Sinai Medical Center Los Angeles CA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jacek Kwiecinski
2Cedars-Sinai Medical Center Los Angeles CA United States
3Cedars-Sinai Medical Center Los Angeles CA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Damini Dey
2Cedars-Sinai Medical Center Los Angeles CA United States
3Cedars-Sinai Medical Center Los Angeles CA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Sebastien Cadet
2Cedars-Sinai Medical Center Los Angeles CA United States
3Cedars-Sinai Medical Center Los Angeles CA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Guido Germano
2Cedars-Sinai Medical Center Los Angeles CA United States
3Cedars-Sinai Medical Center Los Angeles CA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Daniel Berman
2Cedars-Sinai Medical Center Los Angeles CA United States
3Cedars-Sinai Medical Center Los Angeles CA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Philip Adamson
1bBritish Heart Foundation Centre for Cardiovascular Science, Clinical Research Imaging Centre, Edinburgh Heart Centre, University of Edinburgh Edinburgh United Kingdom
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Alastair Moss
1bBritish Heart Foundation Centre for Cardiovascular Science, Clinical Research Imaging Centre, Edinburgh Heart Centre, University of Edinburgh Edinburgh United Kingdom
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Marc Dweck
4University of Edinburgh Edinburgh United Kingdom
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
David Newby
4University of Edinburgh Edinburgh United Kingdom
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Piotr Slomka
2Cedars-Sinai Medical Center Los Angeles CA United States
3Cedars-Sinai Medical Center Los Angeles CA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
Loading

Abstract

451

Objectives: High test-retest reproducibility is required for the translation of coronary 18F-NaF PET imaging into clinical practice. In this study we investigate the feasibility of correcting for variations in the injection-to-scan delays and its relative impact on the test-retest reproducibility.

Methods: Twenty patients with coronary artery disease who underwent repeated hybrid PET/CT angiography (CTA) imaging within 3 weeks were recruited. Both imaging sessions included a 30-min PET acquisition following injection of 248±9 MBq 18F-NaF (injection-to-scan delay = 60 min) and a CTA-scan. All PET datasets were reconstructed in end-diastolic phase (25% of the counts). Coronary lesions were identified on CTA images in arteries with diameter ≥2mm, with stenosis of >25% in the coronary segment and no prior stents. Lesion uptake was quantified from spherical Volume of Interests (VOIs) (radius=5 mm), while background activities were obtained in the right atrium using a cylindrical VOI (length=15 mm, radius=10 mm). Lesions with TBR>1.25 were considered 18F-NaF avid, while lesions with TBR <1.25 were considered 18F-NaF negative. We corrected injection to imaging intervals for all acquisitions by normalizing the injection-to-scan delays to 60 minutes post injection (equation 1): SUV_(Background Corrected) = SUV_(Background)[asterisk] ((1.5092[asterisk]exp(-0.004[asterisk]60)/(1.5092[asterisk]exp(-0.004[asterisk]t)), based on prior study (1). The correction was applied to the extracted blood pool activities for all the acquisitions. We report the injection-to-scan delays and the TBR before and after background blood pool correction (BC). The test-retest evaluations before and after BC were reported as Bland-Altman analyses and coefficient of reproducibility measures.

Results: A total of 47 unique coronary lesions (15 18F-NaF-avid) were identified on CTA. Average injection-to-scan delays were found to be (66±9 min, range 59-101 min). The increased injection-to-scan delays (>60 min) introduced a BC correction factor >1 and, thus, a reduction in the TBR following BC (TBR: Non-corrected=1.18±0.48, BC=1.14±0.46, relative reduction: 2.5±3.8%, range: -0.4% to 17.8%, p=0.98). Correcting for BC increased test-retest reproducibility for all lesions by 19.7% (Coefficient of reproducibility: Non-corrected = 0.437, BC= 0.365, p<0.001). Importantly, in a sub-analysis of 18F-NaF-avid lesions only, the test-retest reproducibility was improved by 25.3% (Coefficient of reproducibility: Non-corrected = 0.628, BC=0.501, p<0.001) (Figure 1).

Conclusions: BC technique significantly improves reproducibility of the coronary plaque assessment utilizing only the PET-image data. (1) Kwiecinski J, Berman DS, Lee S-E, et al. Three-hour delayed imaging improves assessment of coronary 18 F-sodium fluoride PET. J Nucl Med. 2018:jnumed.118.217885.

Figure
  • Download figure
  • Open in new tab
  • Download powerpoint
Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 60, Issue supplement 1
May 1, 2019
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Injection-to-scan delay correction improves scan-rescan reproducibility sodium fluoride (18F-NaF) coronary plaque imaging.
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Injection-to-scan delay correction improves scan-rescan reproducibility sodium fluoride (18F-NaF) coronary plaque imaging.
Martin Lyngby Lassen, Jacek Kwiecinski, Damini Dey, Sebastien Cadet, Guido Germano, Daniel Berman, Philip Adamson, Alastair Moss, Marc Dweck, David Newby, Piotr Slomka
Journal of Nuclear Medicine May 2019, 60 (supplement 1) 451;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Injection-to-scan delay correction improves scan-rescan reproducibility sodium fluoride (18F-NaF) coronary plaque imaging.
Martin Lyngby Lassen, Jacek Kwiecinski, Damini Dey, Sebastien Cadet, Guido Germano, Daniel Berman, Philip Adamson, Alastair Moss, Marc Dweck, David Newby, Piotr Slomka
Journal of Nuclear Medicine May 2019, 60 (supplement 1) 451;
del.icio.us logo Digg logo Reddit logo Twitter logo CiteULike logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Figures & Data
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Cardiovascular

  • Cardiac β-Adrenergic Receptor Downregulation, Evaluated by Cardiac PET, in Chronotropic Incompetence
  • Diagnostic Performance of PET Versus SPECT Myocardial Perfusion Imaging in Patients with Smaller Left Ventricles: A Substudy of the 18F-Flurpiridaz Phase III Clinical Trial
  • Quantification of Macrophage-Driven Inflammation During Myocardial Infarction with 18F-LW223, a Novel TSPO Radiotracer with Binding Independent of the rs6971 Human Polymorphism
Show more Cardiovascular

Cardiovascular Clinical Science: Vulnerable Plaque and Innervation Imaging

  • Comparison of C-11-meta-hydroxyephedrine and N-13-ammonia PET Imaging Biomarkers of Cardiac Sympathetic Innervation and Perfusion in Ischemic Cardiomyopathy
  • First-in-human targeted NPR-C PET/MR imaging of carotid atherosclerosis correlation with ex vivo plaque immunohistochemistry (IHC)
Show more Cardiovascular Clinical Science: Vulnerable Plaque and Innervation Imaging

Similar Articles

SNMMI

© 2023 Journal of Nuclear Medicine

Powered by HighWire