Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Permissions
    • Advertisers
    • Continuing Education
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Permissions
    • Advertisers
    • Continuing Education
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Follow JNM on Twitter
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Subscribe to our RSS feeds
Meeting ReportInstrumentation & Data Analysis Track

Development and implementation of a Joint-Commission compliant phantom program for PET/CT with fully-automated cloud-based analysis.

John Sunderland, Christian Bauer, Reinhard Beichel, Ethan Ulrich, Paul Christian, Raymond Muzic, Martin Lodge, Jonathon Nye, Lance Burrell, Michael Czachowski, Patrick Wojtylak and Leonard Zimmermann
Journal of Nuclear Medicine May 2018, 59 (supplement 1) 570;
John Sunderland
9University of Iowa Iowa City IA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Christian Bauer
10Electrical and Computer Engineering University of Iowa Iowa City IA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Reinhard Beichel
10Electrical and Computer Engineering University of Iowa Iowa City IA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ethan Ulrich
9University of Iowa Iowa City IA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Paul Christian
1Salt Lake City UT United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Raymond Muzic
6University Hospitals Case Medical Center Cleveland OH United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Martin Lodge
5Johns Hopkins University Baltimore MD United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jonathon Nye
3Emory University Atlanta GA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Lance Burrell
4Huntsman Cancer Institute Salt Lake City UT United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Michael Czachowski
2Children's Hospital of Pittsburgh of UPMC Mars PA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Patrick Wojtylak
8University Hospitals of Cleveland Case Medicial Ce Hinckley OH United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Leonard Zimmermann
7University Hospitals Cleveland Medical Center Cleveland OH United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
Loading

Abstract

570

Objectives: In 2015 The Joint Commission published new “Diagnostic Imaging Requirements” that mandated phantom-based PET/CT scanner performance evaluations by diagnostic medical physicists. Image uniformity, high contrast resolution/system spatial resolution, low contrast resolution or detectability, and artifact evaluation are the newly required components. No guidance is given as to which phantoms or what criteria are to be used in these assessments. Since most PET/CT scanners are hospital-based in the US, and 82% of hospitals are currently Joint Commission accredited, these new required evaluations impact the majority of PET/CT scanners in the US. Here we report the development of a phantom-based PET/CT scanner evaluation program designed to be compliant with Joint Commission requirements while providing meaningful and actionable scanner performance information. Methods: The proposed phantom program requires sites to perform two phantom scans. The first scan images a standard uniform 20 cm diameter cylinder phantom filled with aqueous [18F]FDG. The cylinder is centered in the gantry, but tilted at a slightly oblique angle with respect to the z-axis and is imaged for two bed positions at 20-30 minutes per bed position. Images reconstructed using the site’s standard clinical reconstruction yields data for in-plane uniformity, axial uniformity, assessment of quantitative calibration, and reconstructed resolution in the radial and axial directions. Spatial resolution is calculated using measurement of the edge response function using the method of Lodge and Leal (J Nucl Med 2017, Vol 58 701). The second phantom scan uses either the NEMA Image Quality (IQ) phantom, or the new version of the SNMMI Clinical Trials Network (CTN) oncology phantom with NEMA sized spheres. A 4:1 sphere-to-background ratio is used in either case. The phantom data are acquired using the site’s standard oncology protocol including time per bed position and reconstruction parameters (advanced reconstructions allowed). Image data yields a contrast recovery coefficient curve, clinically relevant noise assessment, and assessment of low-contrast lesion detectability. The two phantom image sets are uploaded to a cloud-based server along with phantom-fill documentation. After a manual image quality control check, the datasets sets are exported to a folder that is continuously interrogated (Python). Upon dataset detection, images are automatically downloaded and analyzed in a fully automated fashion (C++, ITK) and a full scanner performance report (PDF) is generated. The report is designed to demonstrate Joint Commission compliance and record other performance metrics. In the final step, a medical physicist reviews the images and PDF report, performs an assessment for lesion detectability and artifacts, and approves the report. In the current plan, reports will be sent directly to the imaging site or independent contract physicist who requested the analysis for co-signature.

Results: Robustness of the automated phantom analysis software for the CTN and NEMA IQ phantoms has been validated across a number of PET/CT systems over a range of orientations and statistical image quality (Ulrich, Med Phys 23 Nov 2017). The uniform phantom algorithm for spatial resolution has been similarly validated. Analysis of three phantom datasets (uniform, NEMA IQ, and CTN) is benchmarked at 5 minutes 20 seconds. Conclusions: An efficient Joint Commission compliant phantom program for PET/CT has been developed and tested using commonly available phantoms and a robust cloud-based analysis tool. Deployment of the program to the general public is planned for the near future. Funding: U01CA140206, R01CA169072

Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 59, Issue supplement 1
May 1, 2018
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Development and implementation of a Joint-Commission compliant phantom program for PET/CT with fully-automated cloud-based analysis.
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Development and implementation of a Joint-Commission compliant phantom program for PET/CT with fully-automated cloud-based analysis.
John Sunderland, Christian Bauer, Reinhard Beichel, Ethan Ulrich, Paul Christian, Raymond Muzic, Martin Lodge, Jonathon Nye, Lance Burrell, Michael Czachowski, Patrick Wojtylak, Leonard Zimmermann
Journal of Nuclear Medicine May 2018, 59 (supplement 1) 570;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Development and implementation of a Joint-Commission compliant phantom program for PET/CT with fully-automated cloud-based analysis.
John Sunderland, Christian Bauer, Reinhard Beichel, Ethan Ulrich, Paul Christian, Raymond Muzic, Martin Lodge, Jonathon Nye, Lance Burrell, Michael Czachowski, Patrick Wojtylak, Leonard Zimmermann
Journal of Nuclear Medicine May 2018, 59 (supplement 1) 570;
del.icio.us logo Digg logo Reddit logo Twitter logo CiteULike logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Instrumentation & Data Analysis Track

  • Deep Learning Based Kidney Segmentation for Glomerular Filtration Rate Measurement Using Quantitative SPECT/CT
  • The Benefit of Time-of-Flight in Digital Photon Counting PET Imaging: Physics and Clinical Evaluation
  • Preclinical validation of a single-scan rest/stress imaging technique for 13NH3 cardiac perfusion studies
Show more Instrumentation & Data Analysis Track

Standardized Imaging Techniques and Performance

  • Assessment of PET image resolution
  • Accuracy of absolute quantitative SPECT/CT in a multi-vendor and multi-center setting
  • Head-to-head comparisons of the PET performance measured using the NEMA standards between digital and analogic last-generation cameras
Show more Standardized Imaging Techniques and Performance

Similar Articles

SNMMI

© 2023 Journal of Nuclear Medicine

Powered by HighWire