Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Permissions
    • Advertisers
    • Continuing Education
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Permissions
    • Advertisers
    • Continuing Education
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Follow JNM on Twitter
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Subscribe to our RSS feeds
Meeting ReportCardiovascular Track

Interaction of patient motion and RV spillover correction on septal wall MBF and MFR

Jonathan Moody, Benjamin Lee, Alexis Poitrasson-Rivière, Richard Weinberg, James Corbett, Edward Ficaro and Venkatesh Murthy
Journal of Nuclear Medicine May 2018, 59 (supplement 1) 438;
Jonathan Moody
1INVIA, LLC Ann Arbor MI United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Benjamin Lee
1INVIA, LLC Ann Arbor MI United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Alexis Poitrasson-Rivière
1INVIA, LLC Ann Arbor MI United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Richard Weinberg
2University of Michigan Ann Arbor MI United States
3University of Michigan Ann Arbor MI United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
James Corbett
2University of Michigan Ann Arbor MI United States
3University of Michigan Ann Arbor MI United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Edward Ficaro
2University of Michigan Ann Arbor MI United States
3University of Michigan Ann Arbor MI United States
1INVIA, LLC Ann Arbor MI United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Venkatesh Murthy
2University of Michigan Ann Arbor MI United States
3University of Michigan Ann Arbor MI United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
Loading

Abstract

438

Objectives: Contemporary clinical software tools have greatly improved the efficiency and robustness of routine myocardial blood flow (MBF) estimation by dynamic cardiac PET. However, such tools do not generally correct for patient motion, and are particularly vulnerable to quantitative errors during the first-pass blood pool phase of the dynamic sequence. Spillover from the right ventricle (RV) into the interventricular septum during this phase can also bias MBF estimates [Hove, 1998; 2003] [Hermansen 1998]. Because uncorrected motion may result in increased apparent spillover, we investigated the potential for RV spillover correction to mitigate the effects of patient motion on regional septal MBF and flow reserve (MFR).

Methods: Consecutive patients (N=105, 72 M; age 64±12 yrs) underwent clinically indicated rest/regadenoson stress myocardial perfusion PET using Rb-82 in list-mode. Dynamic data were binned into 30 frames (16x5s, 6x10s, 3x20s, 4x30s, 1x80s). Patient motion between dynamic PET frames was manually corrected by expert users using the myocardial contours determined from the last 5 minutes of dynamic PET data as a reference. The frequency and magnitude of motion artifact was determined from motion correction vectors. 1-tissue-compartment kinetic models were fit to dynamic data with blood pool spillover correction for both LV and RV (RV+) and with LV spillover correction only (RV-). Bland-Altman plots and relative differences in segmental MBF and MFR estimates in the septum were compared with and without correction for motion (MC+/MC-) and RV spillover (RV+/RV-) with respect to RV+MC+. Results are reported as median(IQR). RESULTS: The median number of frames requiring motion correction were 19 (5, 24) and 18 (2, 23) at rest and stress, respectively. During the blood pool phase (frames 1-20) the median frequency of motion correction was significantly higher than during the tissue uptake phase (frames 21-30) [0.61 vs 0.44 at rest, 0.59 vs 0.38 at stress, both p<0.001]. The magnitude of motion correction was also higher during the blood pool phase [1.3 (0, 4.7) mm vs 0.0 (0, 2.3) mm at rest, 1.3 (0, 5.5) mm vs 0.0 (0, 2.3) mm at stress, both p<0.001]. 525 septal segments were analyzed. Median differences in septal segmental MBF and MFR relative to RV+MC+ were < 10% in all cases (Figure). When motion was corrected (MC+), the effect of uncompensated RV spillover was moderate (Figure, left column, note smaller y-scale compared to center & right columns), with fewer than 10% of septal segments having > 10% MBF or MFR differences (Table). However, without motion correction (MC-) the variability was greatly increased (Figure, middle & right columns). In addition, the number of septal segments with relative differences > 10% were also significantly increased (Table). CONCLUSIONS: The incidence and magnitude of motion artifacts were greater in the blood pool phase. The predominance of motion artifact during this phase tended to amplify RV spillover bias. When motion correction was omitted, large increases in septal MBF and MFR variability were observed which were not mitigated by RV spillover correction. Correction for dynamic PET motion artifact is clinically necessary to reduce regional MBF and MFR variability. RV spillover correction provides an additional smaller reduction in variability but its clinical impact is yet to be determined.

Figure
  • Download figure
  • Open in new tab
  • Download powerpoint
View this table:
  • View inline
  • View popup

Number of septal segments with % difference greater than 10% relative to RV+MC+ ([asterisk]p<0.05)

Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 59, Issue supplement 1
May 1, 2018
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Interaction of patient motion and RV spillover correction on septal wall MBF and MFR
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Interaction of patient motion and RV spillover correction on septal wall MBF and MFR
Jonathan Moody, Benjamin Lee, Alexis Poitrasson-Rivière, Richard Weinberg, James Corbett, Edward Ficaro, Venkatesh Murthy
Journal of Nuclear Medicine May 2018, 59 (supplement 1) 438;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Interaction of patient motion and RV spillover correction on septal wall MBF and MFR
Jonathan Moody, Benjamin Lee, Alexis Poitrasson-Rivière, Richard Weinberg, James Corbett, Edward Ficaro, Venkatesh Murthy
Journal of Nuclear Medicine May 2018, 59 (supplement 1) 438;
del.icio.us logo Digg logo Reddit logo Twitter logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Figures & Data
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Cardiovascular Track

  • To Evaluated the Cardiac Function of Patients with Acute Myocardial Infarction by the Volume and Filling Curve of 99mTc-MIBI SPECT Myocardial Perfusion Imaging
  • Standard versus low-dose rubidium-82 dynamic positron emission tomography imaging with scanner-dependent bias correction for myocardial perfusion imaging and blood flow quantification
  • Evaluation of sympathetic function with PET 11C-hydroxyephedrine (HED) and ammonia (13N-NH3) in a canine pacing model of atrial fibrillation
Show more Cardiovascular Track

Myocardial Blood Flow Using Dynamic Imaging

  • Standard versus low-dose rubidium-82 dynamic positron emission tomography imaging with scanner-dependent bias correction for myocardial perfusion imaging and blood flow quantification
  • Prognostic significance of myocardial flow reserve in the patients with dialysis dependent end stage renal disease evaluated with pharmacological stress N13-ammonia PET
  • The cardiac transit time measured from dynamic lung perfusion scan correlates with right heart hemodynamics: comparison with invasive catheterization and doppler echocardiography
Show more Myocardial Blood Flow Using Dynamic Imaging

Similar Articles

SNMMI

© 2022 Journal of Nuclear Medicine

Powered by HighWire