Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Permissions
    • Advertisers
    • Continuing Education
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Permissions
    • Advertisers
    • Continuing Education
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Follow JNM on Twitter
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Subscribe to our RSS feeds
Meeting ReportTech Students Track

Breakdown Significance of MAA in a Syringe and Vial Post Compounding

Megan Nagel
Journal of Nuclear Medicine May 2018, 59 (supplement 1) 2163;
Megan Nagel
1Froedtert & MCW Milwaukee WI United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
Loading

Abstract

2163

Objectives: The prices of Macroaggregated Albumin (MAA) vials have become more expensive, making it more affordable to order unit doses from commercial pharmacies. The objective of this study is to determine if there is a difference in quality control (QC) results when comparing commercially drawn unit doses that have the potential to sit for 6 hours versus radiopharmacy prepared doses drawn directly from vials at the time of injection. When doing QC, a minimal amount of free TcO4- and hydrolyzed reduced (HR) TcO4- is preferred to ensure that there is a higher amount of technetium bound to the MAA particles.

Methods: QC is done on every compounded kit to make sure that the diagnostic radiopharmaceutical is suitable to administer to the patient. QC consists of a radiochemical quality test, a radionuclide quality test, a chemical impurity test, as well as a pH test. After the 15 minutes’ incubation time for the compounded MAA kit, seven syringes are initially drawn up. To mimic commercially drawn unit doses, six syringes were drawn up for each hour until expiration (time 0-6 hours). A seventh syringe is drawn up to indicate time zero for the immediate QC results of the kit. Every hour, radiochemical QC is done on one of the six syringes and a new sample is drawn up from the MAA vial. Radiochemical quality of the radiopharmaceutical is how much radioactivity in the right chemical form is present in the radiopharmaceutical. Radiochemical quality is evaluated by using chromatography strips designated for Tc99m-MAA. The chromatography test shows what percent of free TcO4- and hydrolyzed reduced TcO4- there is in the compounded kit; ultimately giving you the labeling efficiency. Radionuclide quality test is how much of the radionuclide activity desired there is compared to the total amount of radioactivity of the source. The source being Mo-99 from the Molybdenum generator and the desired radionuclide is Tc-99m. This is only done once for this research right away at time zero when the 15 minute incubation period is over. The ratio should be less than 0.15 microcuries of Mo-99 per millicuries of Tc-99m. Chemical impurity test is testing to see how much aluminum residual in the Tc-99m eluate from the generator, if there is too much aluminum in the eluate it causes a decrease in binding efficiency. Another test is done to evaluate the pH of the radiopharmaceutical that is administered to the patient. Testing the pH is done simply by using pH paper. A pH out of the range of 4.75-7.5 is not acceptable to administer to the patient. Both of these tests are done once initially at time zero and only need to be done once for this research.

Results: Multiple trials were done on five different compounded MAA kits. The lowest QC result was 98.7% from the syringes and the lowest QC result for the vial is 98.8%. There was no correlation of more breakdown of MAA with time, meaning that QC results did not differ as the time of expiration of the kit progressed.

Conclusions: Looking at the results, there is no significant difference in QC data that would lead to the assumption that the breakdown of MAA is greater in a syringe compared to a vial. Ordering unit doses could save the hospital money and therefore this institution will continue to order unit doses from commercial pharmacies without the concern of HR TcO4- or free TcO4- being a problem. FIGURES/IMAGES:

View this table:
  • View inline
  • View popup

View this table:
  • View inline
  • View popup

View this table:
  • View inline
  • View popup

REFERENCES: Loveless VS. Quality Control of Radiopharmaceuticals. Fundamentals of Nuclear Pharmacy. 2009; XV:151-174. doi:10.1007/0-387-21702-9_8.

Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 59, Issue supplement 1
May 1, 2018
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Breakdown Significance of MAA in a Syringe and Vial Post Compounding
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Breakdown Significance of MAA in a Syringe and Vial Post Compounding
Megan Nagel
Journal of Nuclear Medicine May 2018, 59 (supplement 1) 2163;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Breakdown Significance of MAA in a Syringe and Vial Post Compounding
Megan Nagel
Journal of Nuclear Medicine May 2018, 59 (supplement 1) 2163;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Figures & Data
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Tech Students Track

  • Fasting and Warming Prior to Molecular Breast Imaging in Clinical Practice Environment
  • Lu-177 DOTATATE therapy for progressive metastatic neuroendocrine tumors: Multidisciplinary team work and role of technologists, nurses, physicists and physicians.
  • Development of Tc99m DMSA Complex 2 Quality Control Test
Show more Tech Students Track

TS27: Student Tech Papers III

  • Development of Tc99m DMSA Complex 2 Quality Control Test
  • Radiation Exposure to Visitors to Nuclear Medicine Department Waiting Areas
Show more TS27: Student Tech Papers III

Similar Articles

SNMMI

© 2023 Journal of Nuclear Medicine

Powered by HighWire