Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Permissions
    • Advertisers
    • Continuing Education
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Permissions
    • Advertisers
    • Continuing Education
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Follow JNM on Twitter
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Subscribe to our RSS feeds
Meeting ReportInstrumentation & Data Analysis Track

Harmonization of preclinical and clinical PET imaging to support co-clinical imaging research

Richard Laforest, Madhusudan Savaikar and Kooresh Shoghi
Journal of Nuclear Medicine May 2018, 59 (supplement 1) 1741;
Richard Laforest
2Washington University Saint Louis MO United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Madhusudan Savaikar
2Washington University Saint Louis MO United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Kooresh Shoghi
1Mallinckrodt Institute of Radiology Saint Louis MO United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
Loading

Abstract

1741

Introduction: Numerous recent works highlight the limited utility of established tumor cell lines in recapitulating the heterogeneity of tumors in patients. More realistic preclinical cancer models are thought to be provided by transplantable, patient-derived tumor xenografts (PDX). Importantly, the use of PDX ushers new paradigms involving co-clinical imaging trials where novel quantitative imaging (QI) methodologies developed and validated using PDX mice can be implemented in a clinical setting. To that end, there is a need to harmonize preclinical and clinical imaging parameters. This work aims to harmonize imaging performance of animal PET imaging relative to human PET imaging in terms of count recovery and image noise to define data acquisition and image reconstruction guidelines for similar imaging conditions across subject scales.

Methods: The NEMA NU-4 2008 image quality and the Micro Hollow Sphere (Data Spectrum, NC) phantoms were imaged on the Siemens Inveon MM PET/CT. The NEMA NU-4 phantom was filled with 250 uCi (9.25MBq). The hollow sphere phantom was filled with a sphere to background ratio of 6.5:1 and contained a total of 200 uCi (7.4 MBq) (sphere sizes: 5.95, 6.95, 8.23, 9.86 mm). Both phantoms were scanned in listmode for 15 minutes. The NEMA IEC Body Phantom (Data Spectrum, NC, sphere sizes: 10,13,17,22,28,27mm) was filled with a 8.6:1 ratio with a total activity of 1.73 mCi and imaged in the Siemens mMR in listmode for 30 min. On both platforms, attenuation correction was provided by scaling a computed tomography scan of the corresponding phantoms. On both platforms, images were reconstructed with a range of parameters typically used in animal and human imaging applications namely with various number of iterations and post-reconstruction smoothing filter parameters, with and without resolution recovery. Results: Small animal hot rod and hot sphere recovery coefficients (RC) were plotted as a function of size and compared to hot sphere RCs from the human scanner. A range of RCs from 20% to 95% was observed for object size range from 1 mm to 5mm in small animal PET imaging. RCs ranged from 20% to 100% for object size ranging from 10 to 37 mm (as defined by SUV peak). On either platforms, significant dependence of the RC was observed on the reconstruction parameters. Comparing both imaging platforms, a lesion with at 60% RC would have a size between 2-3 mm in small animal PET, this object would be 13 to 16 mm on a human scanner. Image noise was evaluated on an image reconstructed using filtered back projection algorithm (FBP) from data reconstructed using various amount of events on each platform. It was observed that approximately similar noise was achieved on non-filtered images if we take into account the relative volumetric spatial resolution between the two imaging systems. This indicates higher activity needs to be injected per body weight in high resolution animal imaging relative to human imaging.

Conclusions: Taken together, these data illustrate that data acquisition and image reconstruction parameter can be determined to harmonize image properties across scales. This work will discuss optimization of small animal PET imaging conditions and present scenarios where image quality and quantitative accuracy can be compared across subject size scales.

Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 59, Issue supplement 1
May 1, 2018
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Harmonization of preclinical and clinical PET imaging to support co-clinical imaging research
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Harmonization of preclinical and clinical PET imaging to support co-clinical imaging research
Richard Laforest, Madhusudan Savaikar, Kooresh Shoghi
Journal of Nuclear Medicine May 2018, 59 (supplement 1) 1741;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Harmonization of preclinical and clinical PET imaging to support co-clinical imaging research
Richard Laforest, Madhusudan Savaikar, Kooresh Shoghi
Journal of Nuclear Medicine May 2018, 59 (supplement 1) 1741;
del.icio.us logo Digg logo Reddit logo Twitter logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Instrumentation & Data Analysis Track

  • Deep Learning Based Kidney Segmentation for Glomerular Filtration Rate Measurement Using Quantitative SPECT/CT
  • Preclinical validation of a single-scan rest/stress imaging technique for 13NH3 cardiac perfusion studies
  • Comparison of 22 partial volume correction methods for amyloid PET imaging with 11C-PiB
Show more Instrumentation & Data Analysis Track

Data Analysis & Management Posters

  • Evaluation of Quantitative Whole Body Dynamic FDG-PET Using Block Sequence Regularized Expectation Maximization (BSREM) Reconstruction
  • Feasibility of 18F-THK5351 PET quantitation using the Centiloid scale
  • NaF-PET/CT for assessment of temporomandibular joint osseous activity in rheumatoid arthritis patients and healthy subjects
Show more Data Analysis & Management Posters

Similar Articles

SNMMI

© 2022 Journal of Nuclear Medicine

Powered by HighWire