Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Permissions
    • Advertisers
    • Continuing Education
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Editorial Contact
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Permissions
    • Advertisers
    • Continuing Education
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Editorial Contact
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Follow SNMMI on Twitter
  • Visit SNMMI on Facebook
Research ArticlePhysics and Instrumentation

A Postreconstruction Harmonization Method for Multicenter Radiomic Studies in PET

Fanny Orlhac, Sarah Boughdad, Cathy Philippe, Hugo Stalla-Bourdillon, Christophe Nioche, Laurence Champion, Michaël Soussan, Frédérique Frouin, Vincent Frouin and Irène Buvat
Journal of Nuclear Medicine August 2018, 59 (8) 1321-1328; DOI: https://doi.org/10.2967/jnumed.117.199935
Fanny Orlhac
1Imagerie Moléculaire , CEA-SHFJ, INSERM, CNRS, Université Paris-Sud, Université Paris-Saclay, Orsay, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Sarah Boughdad
1Imagerie Moléculaire , CEA-SHFJ, INSERM, CNRS, Université Paris-Sud, Université Paris-Saclay, Orsay, France
2Department of Nuclear Medicine, Institut Curie–René Huguenin, Saint-Cloud, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Cathy Philippe
3NeuroSpin/UNATI, CEA, Université Paris-Saclay, Gif-sur-Yvette, France; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Hugo Stalla-Bourdillon
3NeuroSpin/UNATI, CEA, Université Paris-Saclay, Gif-sur-Yvette, France; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Christophe Nioche
1Imagerie Moléculaire , CEA-SHFJ, INSERM, CNRS, Université Paris-Sud, Université Paris-Saclay, Orsay, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Laurence Champion
2Department of Nuclear Medicine, Institut Curie–René Huguenin, Saint-Cloud, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Michaël Soussan
1Imagerie Moléculaire , CEA-SHFJ, INSERM, CNRS, Université Paris-Sud, Université Paris-Saclay, Orsay, France
4Department of Nuclear Medicine, AP-HP, Hôpital Avicenne, Bobigny, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Frédérique Frouin
1Imagerie Moléculaire , CEA-SHFJ, INSERM, CNRS, Université Paris-Sud, Université Paris-Saclay, Orsay, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Vincent Frouin
3NeuroSpin/UNATI, CEA, Université Paris-Saclay, Gif-sur-Yvette, France; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Irène Buvat
1Imagerie Moléculaire , CEA-SHFJ, INSERM, CNRS, Université Paris-Sud, Université Paris-Saclay, Orsay, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF
Loading

Abstract

Several reports have shown that radiomic features are affected by acquisition and reconstruction parameters, thus hampering multicenter studies. We propose a method that, by removing the center effect while preserving patient-specific effects, standardizes features measured from PET images obtained using different imaging protocols. Methods: Pretreatment 18F-FDG PET images of patients with breast cancer were included. In one nuclear medicine department (department A), 63 patients were scanned on a time-of-flight PET/CT scanner, and 16 lesions were triple-negative (TN). In another nuclear medicine department (department B), 74 patients underwent PET/CT on a different brand of scanner and a different reconstruction protocol, and 15 lesions were TN. The images from department A were smoothed using a gaussian filter to mimic data from a third department (department A-S). The primary lesion was segmented to obtain a lesion volume of interest (VOI), and a spheric VOI was set in healthy liver tissue. Three SUVs and 6 textural features were computed in all VOIs. A harmonization method initially described for genomic data was used to estimate the department effect based on the observed feature values. Feature distributions in each department were compared before and after harmonization. Results: In healthy liver tissue, the distributions significantly differed for 4 of 9 features between departments A and B and for 6 of 9 between departments A and A-S (P < 0.05, Wilcoxon test). After harmonization, none of the 9 feature distributions significantly differed between 2 departments (P > 0.1). The same trend was observed in lesions, with a realignment of feature distributions between the departments after harmonization. Identification of TN lesions was largely enhanced after harmonization when the cutoffs were determined on data from one department and applied to data from the other department. Conclusion: The proposed harmonization method is efficient at removing the multicenter effect for textural features and SUVs. The method is easy to use, retains biologic variations not related to a center effect, and does not require any feature recalculation. Such harmonization allows for multicenter studies and for external validation of radiomic models or cutoffs and should facilitate the use of radiomic models in clinical practice.

  • texture analysis
  • tumor heterogeneity
  • PET
  • radiomics
  • harmonization

Footnotes

  • Published online Jan. 4, 2018.

  • © 2018 by the Society of Nuclear Medicine and Molecular Imaging.
View Full Text
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 59 (8)
Journal of Nuclear Medicine
Vol. 59, Issue 8
August 1, 2018
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
A Postreconstruction Harmonization Method for Multicenter Radiomic Studies in PET
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
A Postreconstruction Harmonization Method for Multicenter Radiomic Studies in PET
Fanny Orlhac, Sarah Boughdad, Cathy Philippe, Hugo Stalla-Bourdillon, Christophe Nioche, Laurence Champion, Michaël Soussan, Frédérique Frouin, Vincent Frouin, Irène Buvat
Journal of Nuclear Medicine Aug 2018, 59 (8) 1321-1328; DOI: 10.2967/jnumed.117.199935

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
A Postreconstruction Harmonization Method for Multicenter Radiomic Studies in PET
Fanny Orlhac, Sarah Boughdad, Cathy Philippe, Hugo Stalla-Bourdillon, Christophe Nioche, Laurence Champion, Michaël Soussan, Frédérique Frouin, Vincent Frouin, Irène Buvat
Journal of Nuclear Medicine Aug 2018, 59 (8) 1321-1328; DOI: 10.2967/jnumed.117.199935
del.icio.us logo Digg logo Reddit logo Twitter logo CiteULike logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF

Related Articles

  • This Month in JNM
  • PubMed
  • Google Scholar

Cited By...

  • Pretreatment 18F-FDG PET/CT Radiomics Predict Local Recurrence in Patients Treated with Stereotactic Body Radiotherapy for Early-Stage Non-Small Cell Lung Cancer: A Multicentric Study
  • Introduction to Radiomics
  • Tumor Subregion Evolution-Based Imaging Features to Assess Early Response and Predict Prognosis in Oropharyngeal Cancer
  • Reply to E. Laffon et al.
  • Radiomics: Data Are Also Images
  • Optimized Feature Extraction for Radiomics Analysis of 18F-FDG PET Imaging
  • Google Scholar

More in this TOC Section

  • Ultra-Fast List-Mode Reconstruction of Short PET Frames and Example Applications
  • Investigating Low-Dose Image Quality in Whole-Body Pediatric 18F-FDG Scans Using Time-of-Flight PET/MRI
  • Data-Driven Respiratory Gating Outperforms Device-Based Gating for Clinical 18F-FDG PET/CT
Show more Physics and Instrumentation

Similar Articles

Keywords

  • texture analysis
  • tumor heterogeneity
  • PET
  • Radiomics
  • harmonization
SNMMI

© 2021 Journal of Nuclear Medicine

Powered by HighWire