Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Permissions
    • Advertisers
    • Continuing Education
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Permissions
    • Advertisers
    • Continuing Education
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Follow JNM on Twitter
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Subscribe to our RSS feeds
Meeting ReportInstrumentation & Data Analysis Track

Managing Quality Assurance for Oncologic Bone Imaging in Multi-center Clinical Trials - Experiences from the NCTN Imaging and Radiation Oncology Core (IROC) Service

Prayna Bhatia, Shivangi Vora, David Poon, Ajay Siva, Talha Saif, Preethi Subramanian, Timothy Sbory, Jun Zhang and Michael Knopp
Journal of Nuclear Medicine May 2016, 57 (supplement 2) 1918;
Prayna Bhatia
5Wright Center of Innovation The Ohio State University Columbus OH United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Shivangi Vora
5Wright Center of Innovation The Ohio State University Columbus OH United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
David Poon
5Wright Center of Innovation The Ohio State University Columbus OH United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ajay Siva
5Wright Center of Innovation The Ohio State University Columbus OH United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Talha Saif
1Hilliard OH United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Preethi Subramanian
3The Ohio State University Columbus OH United States
4The Ohio State University Columbus OH United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Timothy Sbory
5Wright Center of Innovation The Ohio State University Columbus OH United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jun Zhang
2Radiology Ohio State University Wexner Medical Center Columbus OH United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Michael Knopp
3The Ohio State University Columbus OH United States
4The Ohio State University Columbus OH United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
Loading

Abstract

1918

Objectives To report on the experience of the Imaging and Radiation Oncology Core (IROC) providing quality assurance management in a multi-center clinical trial utilizing nuclear medicine bone imaging (NaF PET or Tc99m whole-body imaging) and the processes and data quality assessment methodologies used. We identify critical challenges and common non-compliant items.

Methods A total of 782 patients with 2,158 bone imaging examinations (63 NaF PET, 2,095 Tc-99m whole-body and 30 SPECT) from more than 250 credentialed institutions were processed by the IROC Ohio team and included in this assessment. Established, SOP driven quality control (QC) process were used to determine data compliance and identify the most common factors that are responsible for non-compliance in nuclear medicine bone imaging (Tc-99m, NaF PET and SPECT). Standard NIH protocol guidelines for NaF PET/CT acquisition were used in determining the imaging protocol requirements. Trial-specific data compliance was evaluated. A standard QC scoring system was adapted and implemented to determine the quality protocol adherence as well as the overall imaging examinations.

Results The QC scoring system identified an overall protocol compliance focused on 782 enrolled patients as 97% compliant , 3% non-compliant. The most common imaging protocol deviation was the non-compliance with the time between injection and initiation of emission scanning (16%). The 2nd most common deviations were inconsistencies between baseline and follow-up studies such as: different bone imaging modality used (2.5%), poor imaging quality (~15%), different scanner used (~13%), and different isotope used (<3%). Overall, 99 % of Tc-99m Bone imaging was compliant and 84% of NaF PET/CT was compliant.

Conclusions As response or disease burden adaptive clinical oncologic trials dependent on the extend on osseous metastasis become more prevalent, a set of quality assurance standards was implemented and demonstrated to guide quality management and assist health care professionals in performing, interpreting, and reporting results for clinical trials utilizing bone imaging. Real-time quality assurance with feedback is imperative to achieve high protocol compliance rates. With proper training of the clinical trial teams and implementation of standard operating procedures, high compliance rates can be achieved.

Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 57, Issue supplement 2
May 1, 2016
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Managing Quality Assurance for Oncologic Bone Imaging in Multi-center Clinical Trials - Experiences from the NCTN Imaging and Radiation Oncology Core (IROC) Service
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Managing Quality Assurance for Oncologic Bone Imaging in Multi-center Clinical Trials - Experiences from the NCTN Imaging and Radiation Oncology Core (IROC) Service
Prayna Bhatia, Shivangi Vora, David Poon, Ajay Siva, Talha Saif, Preethi Subramanian, Timothy Sbory, Jun Zhang, Michael Knopp
Journal of Nuclear Medicine May 2016, 57 (supplement 2) 1918;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Managing Quality Assurance for Oncologic Bone Imaging in Multi-center Clinical Trials - Experiences from the NCTN Imaging and Radiation Oncology Core (IROC) Service
Prayna Bhatia, Shivangi Vora, David Poon, Ajay Siva, Talha Saif, Preethi Subramanian, Timothy Sbory, Jun Zhang, Michael Knopp
Journal of Nuclear Medicine May 2016, 57 (supplement 2) 1918;
del.icio.us logo Digg logo Reddit logo Twitter logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Instrumentation & Data Analysis Track

  • Deep Learning Based Kidney Segmentation for Glomerular Filtration Rate Measurement Using Quantitative SPECT/CT
  • Preclinical validation of a single-scan rest/stress imaging technique for 13NH3 cardiac perfusion studies
  • Comparison of 22 partial volume correction methods for amyloid PET imaging with 11C-PiB
Show more Instrumentation & Data Analysis Track

MTA II: Data Analysis & Management Posters

  • Localized Quantitative Analysis of Positron Emission Tomography (PET) for Temporal Lobe Epilepsy Lateralization and Surgical Intervention
  • An adaptive motion correction method for PET/CT Brain Imaging
  • Detection of dementia-related hypometabolism using two different age-adjusted reference FDG- PET databases
Show more MTA II: Data Analysis & Management Posters

Similar Articles

SNMMI

© 2022 Journal of Nuclear Medicine

Powered by HighWire