Research ArticleClinical Investigations
Clinical Evaluation of Zero-Echo-Time Attenuation Correction for Brain 18F-FDG PET/MRI: Comparison with Atlas Attenuation Correction
Tetsuro Sekine, Edwin E.G.W. ter Voert, Geoffrey Warnock, Alfred Buck, Martin Huellner, Patrick Veit-Haibach and Gaspar Delso
Journal of Nuclear Medicine December 2016, 57 (12) 1927-1932; DOI: https://doi.org/10.2967/jnumed.116.175398
Tetsuro Sekine
1Department of Nuclear Medicine, University Hospital Zurich, Zurich, Switzerland
2Department of Radiology, Nippon Medical School, Tokyo, Japan
Edwin E.G.W. ter Voert
1Department of Nuclear Medicine, University Hospital Zurich, Zurich, Switzerland
Geoffrey Warnock
1Department of Nuclear Medicine, University Hospital Zurich, Zurich, Switzerland
3Institute of Pharmacology & Toxicology, University of Zurich, Zurich, Switzerland
4PMOD Technologies Ltd., Zurich, Switzerland
Alfred Buck
1Department of Nuclear Medicine, University Hospital Zurich, Zurich, Switzerland
Martin Huellner
1Department of Nuclear Medicine, University Hospital Zurich, Zurich, Switzerland
5Department of Neuroradiology, University Hospital Zurich, Zurich, Switzerland
Patrick Veit-Haibach
1Department of Nuclear Medicine, University Hospital Zurich, Zurich, Switzerland
6Division of Diagnostic and Interventional Radiology, Department of Medical Radiology, University Hospital Zurich, Zurich, Switzerland; and
Gaspar Delso
7GE Healthcare Waukesha, Wisconsin
Data supplements
Supplemental Data
Files in this Data Supplement:
In this issue
Journal of Nuclear Medicine
Vol. 57, Issue 12
December 1, 2016
Clinical Evaluation of Zero-Echo-Time Attenuation Correction for Brain 18F-FDG PET/MRI: Comparison with Atlas Attenuation Correction
Tetsuro Sekine, Edwin E.G.W. ter Voert, Geoffrey Warnock, Alfred Buck, Martin Huellner, Patrick Veit-Haibach, Gaspar Delso
Journal of Nuclear Medicine Dec 2016, 57 (12) 1927-1932; DOI: 10.2967/jnumed.116.175398
Clinical Evaluation of Zero-Echo-Time Attenuation Correction for Brain 18F-FDG PET/MRI: Comparison with Atlas Attenuation Correction
Tetsuro Sekine, Edwin E.G.W. ter Voert, Geoffrey Warnock, Alfred Buck, Martin Huellner, Patrick Veit-Haibach, Gaspar Delso
Journal of Nuclear Medicine Dec 2016, 57 (12) 1927-1932; DOI: 10.2967/jnumed.116.175398
Jump to section
Related Articles
Cited By...
- [18F]DPA-714 PET Imaging in the Presurgical Evaluation of Patients With Drug-Resistant Focal Epilepsy
- Brain and systemic inflammation in de novo Parkinsons disease
- A Path to Qualification of PET/MRI Scanners for Multicenter Brain Imaging Studies: Evaluation of MRI-Based Attenuation Correction Methods Using a Patient Phantom
- In vivo synaptic density loss is related to tau deposition in amnestic mild cognitive impairment
- A Quantitative Evaluation of Joint Activity and Attenuation Reconstruction in TOF PET/MR Brain Imaging
- Generation of PET Attenuation Map for Whole-Body Time-of-Flight 18F-FDG PET/MRI Using a Deep Neural Network Trained with Simultaneously Reconstructed Activity and Attenuation Maps
- Synthesis of Patient-Specific Transmission Data for PET Attenuation Correction for PET/MRI Neuroimaging Using a Convolutional Neural Network
- Zero-Echo-Time and Dixon Deep Pseudo-CT (ZeDD CT): Direct Generation of Pseudo-CT Images for Pelvic PET/MRI Attenuation Correction Using Deep Convolutional Neural Networks with Multiparametric MRI
- Evaluation of Sinus/Edge-Corrected Zero-Echo-Time-Based Attenuation Correction in Brain PET/MRI
- Long-Delay Arterial Spin Labeling Provides More Accurate Cerebral Blood Flow Measurements in Moyamoya Patients: A Simultaneous Positron Emission Tomography/MRI Study
- The Effect of Susceptibility Artifacts Related to Metallic Implants on Adjacent-Lesion Assessment in Simultaneous TOF PET/MR