Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Permissions
    • Advertisers
    • Continuing Education
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Permissions
    • Advertisers
    • Continuing Education
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Follow JNM on Twitter
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Subscribe to our RSS feeds
Meeting ReportInstrumentation & Data Analysis

Performance characteristics of a novel clustered multi-pinhole technology for simultaneous high-resolution SPECT/PET

Kenta Miwa, Masayuki Inubushi, Yasuto Takeuchi, Tetsuro Katafuchi, Mitsuru Koizumi, Tsuneo Saga and Masayuki Sasaki
Journal of Nuclear Medicine May 2015, 56 (supplement 3) 1869;
Kenta Miwa
1Nuclear Medicine, Cancer Institute Hospital of JFCR, Tokyo, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Masayuki Inubushi
2Nuclear Medicine, Kawasaki Medical School, Kurashiki, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Yasuto Takeuchi
3Molecular Imaging Center, National Institute of Radiological Sciences, Chiba, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Tetsuro Katafuchi
4Radiological Technology, Gifu University of Medical Science, Gifu, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Mitsuru Koizumi
1Nuclear Medicine, Cancer Institute Hospital of JFCR, Tokyo, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Tsuneo Saga
3Molecular Imaging Center, National Institute of Radiological Sciences, Chiba, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Masayuki Sasaki
5Health Sciences, Kyushu University, Fukuoka, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
Loading

Abstract

1869

Objectives The present study experimentally evaluated the detailed performance characteristics of the clustered multi-pinhole system for simultaneous 99mTc and 18F imaging from the user perspective.

Methods Spatial resolution, sensitivity, count rate linearity were determined for the VECTor system (MILabs). Two hot-rod micro resolution phantoms with 6 sectors were created to test the resolution of 99mTc and 18F. Sensitivity and count rate linearity were measured by scanning 99mTc and 18F point sources positioned at the center of the field of view. Furthermore, we quantified the influence of 18F on 99mTc SPECT images. The ratios of SPECT counts on the 99mTc-only and simultaneous 18F-99mTc at various time points were evaluated as a function of the 18F-to-99mTc activity concentration ratio.

Results The 0.5-mm hot-rods can be visually distinguished in the 99mTc image, and 0.8-mm rods for 18F remained clearly visible. The point source sensitivity was 2,800 cps/MBq for 99mTc and 2,899 cps/MBq for 18F, respectively. Count rates up to 120,000 cps for one bed position were linear for the activity concentration. Spill-over from 18F into 99mTc SPECT images was negligible when the activity concentration of the administered 18F solution exceeded that of the 99mTc solution by up to a factor of 2.

Conclusions We evaluated the performance characteristics of the VECTor that lead to determination of the optimal administered doses of 99mTc and 18F tracers. We found that the VECTor achieved high resolution and high sensitivity as well as good 99mTc and 18F linearity. Simultaneous SPECT/PET imaging with 99mTc and 18F tracers, and stand-alone 99mTc and 18F imaging using clustered pinhole collimators, is feasible and practical for a wide range of research applications using small animals.

Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 56, Issue supplement 3
May 1, 2015
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Performance characteristics of a novel clustered multi-pinhole technology for simultaneous high-resolution SPECT/PET
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Performance characteristics of a novel clustered multi-pinhole technology for simultaneous high-resolution SPECT/PET
Kenta Miwa, Masayuki Inubushi, Yasuto Takeuchi, Tetsuro Katafuchi, Mitsuru Koizumi, Tsuneo Saga, Masayuki Sasaki
Journal of Nuclear Medicine May 2015, 56 (supplement 3) 1869;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Performance characteristics of a novel clustered multi-pinhole technology for simultaneous high-resolution SPECT/PET
Kenta Miwa, Masayuki Inubushi, Yasuto Takeuchi, Tetsuro Katafuchi, Mitsuru Koizumi, Tsuneo Saga, Masayuki Sasaki
Journal of Nuclear Medicine May 2015, 56 (supplement 3) 1869;
del.icio.us logo Digg logo Reddit logo Twitter logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Instrumentation & Data Analysis

  • Ray-Scan 64 PET/CT performance evaluation and clinical application
  • Evaluation of dedicated PET/MR breast coil in integrated PET/MR system for simultaneous PET/MR breast imaging
  • MR performance evaluation of an RF-penetrable PET insert with integrated RF receive coil for simultaneous PET/MRI
Show more Instrumentation & Data Analysis

MTA II: Instrumentation Posters

  • Dedicated cardiac SPECT imaging with multi-pinhole collimators on a clinical scanner
  • Hybrid X-ray Fluorescence, Luminescence and Transmission Computed Tomography for Image-Guided Nanoparticle Mediated X-ray Micro-Beam Therapy