Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Permissions
    • Advertisers
    • Continuing Education
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Permissions
    • Advertisers
    • Continuing Education
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Follow JNM on Twitter
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Subscribe to our RSS feeds
Meeting ReportInstrumentation & Data Analysis: Image Generation

Ultrafast [123Iode]FP-CIT SPECT imaging on new gamma camera with semiconductor detector technique: First clinical validation

Alban Bailliez, Tanguy Blaire, Sylvie Petit, Gauthier Calais, Arnaud Kwiatkowski and Patrick Hautecoeur
Journal of Nuclear Medicine May 2011, 52 (supplement 1) 2013;
Alban Bailliez
1Médecine Nucléaire, Polyclinique du Bois, LILLE, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Tanguy Blaire
1Médecine Nucléaire, Polyclinique du Bois, LILLE, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Sylvie Petit
1Médecine Nucléaire, Polyclinique du Bois, LILLE, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Gauthier Calais
2Service de Neurologie, Hopital Saint Philibert GHICL, LILLE, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Arnaud Kwiatkowski
2Service de Neurologie, Hopital Saint Philibert GHICL, LILLE, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Patrick Hautecoeur
2Service de Neurologie, Hopital Saint Philibert GHICL, LILLE, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
Loading

Abstract

2013

Objectives To assess the feasability and diagnostic performance of a novel ultrafast gamma camera with cadmium-zinc-telluride (CZT) solid-state semiconductor detectors for striatal dopamine transporter uptake SPECT imaging (DaTSCAN).

Methods We first performed two phantoms studies (one normal and one pathological) to examine the feasability and the quantification of this method. Afterwards, our observationnal case-only prospective study comprised 50 consecutive patients who underwent a [123Iode]FP-CIT SPECT standard imaging protocol (EANM Guidelines). Scanning was performed first on a conventional dual-detector SPECT gamma camera (Hawkeye HD, GE Healthcare) with a 35-min acquisition time. All scans were immediately repeated on an ultrafast CZT camera (Discovery NM530c Alcyone, GE Healthcare) with a 10-min scan time and reconstructed from list-mode raw data to obtain scan durations of 1 min, 2 min, etc., up to a maximum of 10 min. For each of the scan durations, image quality was graded visually and clinical agreement (normal, abnormal, equivocal) between CZT and SPECT was assessed for each patient and each nigrostriatal subregion by 3 experimented independents nuclear physicians. Semi-quantitative subregional nigrostriatal tracer uptake values obtained using CZT were compared with those obtained using conventional SPECT by intraclass correlation and by Bland-Altman limits of agreement results.

Results The total counts were four to fivefold upper on CZT camera and no motion artifacts were observed. There was excellent clinical agreement between CZT and conventionnal SPECT on a per-patient basis (87 %) and a per-striatal uptake basis (89 %) as shown by highly significant correlation between subregional striatal tracer uptake values (r=0.89, p<0.001).

Conclusions This CZT solid-state detector system allows a substantially reduction in scan time and provides clinical information equivalent to conventional standard [123Iode]FP-CIT SPECT

Back to top

In this issue

Journal of Nuclear Medicine
Vol. 52, Issue supplement 1
May 2011
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Ultrafast [123Iode]FP-CIT SPECT imaging on new gamma camera with semiconductor detector technique: First clinical validation
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Ultrafast [123Iode]FP-CIT SPECT imaging on new gamma camera with semiconductor detector technique: First clinical validation
Alban Bailliez, Tanguy Blaire, Sylvie Petit, Gauthier Calais, Arnaud Kwiatkowski, Patrick Hautecoeur
Journal of Nuclear Medicine May 2011, 52 (supplement 1) 2013;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Ultrafast [123Iode]FP-CIT SPECT imaging on new gamma camera with semiconductor detector technique: First clinical validation
Alban Bailliez, Tanguy Blaire, Sylvie Petit, Gauthier Calais, Arnaud Kwiatkowski, Patrick Hautecoeur
Journal of Nuclear Medicine May 2011, 52 (supplement 1) 2013;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Instrumentation & Data Analysis: Image Generation

  • Evaluation of a 4D PET image reconstruction method with respiratory motion compensation in a patient study
  • A novel semi-automatic method to quantify human brown adipose tissue (BAT) activity on 18F-FDG PET-CT
  • Investigation of the feasibility of dynamic cardiac imaging with a dual detector gamma camera (DDGC)
Show more Instrumentation & Data Analysis: Image Generation

Image Generation Posters

  • On Enhancing Monte-Carlo Scatter Correction for Y90 Bremsstrahlung SPECT using Guided Filtering