Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Permissions
    • Advertisers
    • Continuing Education
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Permissions
    • Advertisers
    • Continuing Education
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Follow JNM on Twitter
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Subscribe to our RSS feeds
OtherSPECIAL CONTRIBUTIONS

MIRD Dose Estimate Report No. 20: Radiation Absorbed-Dose Estimates for 111In- and 90Y-Ibritumomab Tiuxetan

Darrell R. Fisher, Sui Shen and Ruby F. Meredith
Journal of Nuclear Medicine April 2009, 50 (4) 644-652; DOI: https://doi.org/10.2967/jnumed.108.057331
Darrell R. Fisher
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Sui Shen
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ruby F. Meredith
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

This article has a correction. Please see:

  • Errata - April 01, 2012

Abstract

Absorbed-dose calculations provide a scientific basis for evaluating the biologic effects associated with administered radiopharmaceuticals. In cancer therapy, radiation dosimetry supports treatment planning, dose-response analyses, predictions of therapy effectiveness, and completeness of patient medical records. In this study, we evaluated the organ radiation absorbed doses from intravenously administered 111In- and 90Y-ibritumomab tiuxetan. Methods: Ten patients (6 men and 4 women) with non-Hodgkin lymphoma, cared for at 3 different medical centers, were administered the tracer 111In-ibritumomab tiuxetan and assessed using planar scintillation camera imaging at 5 time points and CT–organ volumetrics to determine patient-specific organ biokinetics and dosimetry. Explicit attenuation correction based on the transmission scan or transmission measurements provided the fraction of 111In-administered activity in 7 major organs, the whole body, and remainder tissues over time through complete decay. Time–activity curves were constructed, and radiation doses were calculated using MIRD methods and implementing software. Results: Mean radiation absorbed doses for 111In- and for 90Y-ibritumomab tiuxetan administered to 10 cancer patients are reported for 24 organs and the whole body. Biologic uptake and retention data are given for 7 major source organs, remainder tissues, and the whole body. Median absorbed dose values calculated by this method were compared with previously published dosimetry for ibritumomab tiuxetan and the product package insert. Conclusion: In high-dose radioimmunotherapy, the importance of patient-specific dosimetry becomes obvious when the objective of treatment planning is to achieve disease cures, safely, by limiting radiation dose to any critical normal organ to its maximum tolerable value. Compared with the current package insert, we found differences in median absorbed dose by multiples of 24 in the kidneys, 1.8 in the red marrow, 0.65 in the liver, 0.077 in the intestinal wall, 0.30 in the lungs, 0.46 in the spleen, and 0.34 in the heart wall.

  • 90Y-ibritumomab tiuxetan
  • Zevalin
  • 111In-ibritumomab tiuxetan
  • MIRD dose estimate report
  • lymphoma
  • dosimetry
  • antibody
  • radiopharmaceutical

Ibritumomab tiuxetan (Zevalin; Cell Therapeutics, Inc.) labeled with 90Y or 111In is the first therapeutic radionuclide–antibody conjugate approved by the U.S. Food and Drug Administration (February 2002). Treatment with 90Y-ibritumomab tiuxetan is indicated for patients with relapsed or refractory low-grade, follicular, or CD20+ transformed B-cell non-Hodgkin lymphoma and is approved as part of a therapeutic regimen involving rituximab (Rituxan; Genentech, Inc.). Tiuxetan is the chelator that binds 111In or 90Y to the antibody.

111In-ibritumomab tiuxetan is administered intravenously as a tracer to assess labeled antibody biodistribution and dosimetry, and 90Y-ibritumomab tiuxetan is administered later, intravenously, as the cancer therapy agent. Patient-specific variables influence radiopharmaceutical behavior and, consequently, the organ-absorbed doses from one patient to another. The purpose of this dose estimate report was to calculate the absorbed doses from intravenously administered 111In- and 90Y-ibritumomab tiuxetan for a small population of lymphoma patients and to evaluate the observed variability.

The biokinetics and dosimetry of 111In- and 90Y-ibritumomab tiuxetan were described previously by others (1–5), and dose estimates for 90Y and 111In are summarized in the ibritumomab tiuxetan product package insert (6). Cremonesi et al. (7) recently analyzed and compared dose estimates for 90Y-ibritumomab tiuxetan in 22 patients by 3 different methods. In recommending patient-specific dosimetry with image correction, Cremonesi et al. (7) showed that oversimplified dosimetry provides inaccurate information on dose to critical organs that could affect the amount of 90Y administered and the timing of stem cell transplantation. Assié et al. (8) also showed the importance of patient-specific dosimetry by various methods on assessment of dose from 90Y-ibritumomab tiuxetan. Our study analyzes the biokinetics and dosimetry of 111In- and 90Y-ibritumomab tiuxetan in 10 carefully studied patients representing 3 medical centers. In light of prior analyses by other investigators, the objectives of this work were to generate a MIRD Committee dose estimate for 111In- and 90Y-ibritumomab tiuxetan, base the dose estimate on quantitative imaging that accounted for attenuation correction and background correction of the 111In activity in organs, use patient-specific data on organ mass and body weight, and base this dose assessment on nuclear datasets provided in OLINDA-EXM (Vanderbilt University) (9), a calculational tool that implements the MIRD schema (10). Results of this study are compared with data in the current product package insert and with recently reported studies for the same radiopharmaceutical.

Mean radiation absorbed doses per unit intake by intravenous infusion of 111In-ibritumomab tiuxetan and 90Y-ibritumomab tiuxetan are given in Tables 1 and 2. The biodistribution data, radionuclide nuclear data, and dosimetric assumptions supporting these calculations are presented in this article.

View this table:
  • View inline
  • View popup
TABLE 1

Radiation Absorbed Doses per Unit Administered Activity from Intravenous Administration of 111In-Ibritumomab Tiuxetan

View this table:
  • View inline
  • View popup
TABLE 2

Radiation Absorbed Doses per Unit Administered Activity from Intravenous Administration of 90Y-Ibritumomab Tiuxetan

Radiopharmaceutical

90Y-ibritumomab tiuxetan is an anti-CD20 murine IgG1 κ-monoclonal antibody (ibritumomab) conjugate using the linker-chelator (tiuxetan). The immunoconjugate results from a thiourea covalent bond between ibritumomab and the linker-chelator tiuxetan and has the form (N-(2-bis(carboxymethyl)amino)-3-(p-isothiocyanatophenyl)-propyl)-(N-(2-bis(carboxymethyl)-amino)-2-(methyl)-ethyl)glycine. This 148-kDa antibody conjugate provides a conformationally restricted ligand for trivalent 111In or 90Y (11).

The radiopharmaceutical is given to patients using a 2-step treatment scheme. In step 1, unlabeled rituximab (250 mg/m2) is given intravenously, followed within 4 h by 111In-ibritumomab tiuxetan (185 MBq) for biodistribution assessment. Rituximab induces complement-dependent cytotoxicity, antibody-dependent cell-mediated cytotoxicity, and programmed cell death (apoptosis) (12).

According to the product instructions for ibritumomab tiuxetan (6), the diagnostic infusion with 111In-ibritumomab tiuxetan is to be imaged at 48–72 h (and possibly at other selected time points over the first 6 d) to establish the uptake and distribution of ibritumomab in the patient. In step 2, on day 7, 8, or 9, unlabeled rituximab (250 mg/m2) is administered again, followed within 4 h by a therapeutic infusion of 90Y-ibritumomab tiuxetan (14.8 MBq/kg of body weight, up to 1,184 MBq) (1). In this study, blood samples were also collected and counted for 111In activity to determine retention in serum.

Nuclear Data

111In (valence, +3) is cyclotron-produced by the proton irradiation of 112Cd-enriched targets according to the reaction 112Cd(p,2n)111In. 111In decays with a physical half-life (t1/2) of 67.3 h by electron capture to stable 111Cd. The physical emission data for 111In used in OLINDA-EXM are shown in Table 3 (9,13).

View this table:
  • View inline
  • View popup
TABLE 3

Nuclear Data for 111In

90Y (valence, +2) is obtained from the natural decay of its parent, 90Sr (t1/2, 29 y), which is in turn a product of 235U fission in a nuclear reactor. 90Y is separated radiochemically from 90Sr using a series of precipitation and filtration steps (14) or using a series of strontium-selective chromatographic columns. 90Y decays with a physical t1/2 of 64 h by β(−) emission to stable 90Zr. The physical emission data for 90Y (9,13) are shown in Table 4.

View this table:
  • View inline
  • View popup
TABLE 4

Nuclear Data for 90Y

MATERIALS AND METHODS

Subjects

For this dose-estimate study, we selected a study population of 10 (6 men and 4 women) non-Hodgkin B-cell lymphoma patients who consented to more extensive quantitative imaging than required by the routine ibritumomab tiuxetan protocol. Patients were the first consecutively entered, with complete data collection, into a multiinstitutional trial sponsored by Biogen Idec, Inc., at the University of Alabama at Birmingham; Stanford University at Palo Alto, California; and the Mayo Clinic in Rochester, Minnesota, during 2002 to 2005. The lymphoma patients had characteristics similar to those included in prior dosimetry studies (1–5), from which the ibritumomab tiuxetan package insert data (6) were originally obtained: patients had failed 2 or more prior treatment regimens, had adequate organ function, had less than 25% marrow involvement, and had not received prior external-beam radiation to 25% or more of active marrow. No patients in this study showed evidence of human antimouse antibody response at the time of imaging, determined by the double-antigen method (15).

Antibody

Ibritumomab binds specifically to the CD20 antigen on human B-cell lymphocytes. The CD20 antigen is expressed on more than 90% of B-cell non-Hodgkin lymphomas but is not expressed on hematopoietic stem cells, normal plasma cells, or other normal, nonlymphatic tissues (16,17). The CD20 antigen is not appreciably shed from the cell surface and does not internalize on antibody binding (17).

Biologic Data

After infusion, 111In- and 90Y-ibritumomab tiuxetan are distributed by circulating blood to the organs and tissues of the body. Over time, the postinfusion uptake, retention, and clearance of radiolabeled antibody in and from the major normal organs (kidneys, liver, lungs, spleen, heart, red marrow, and testes) and the whole body may be measured using nuclear medicine imaging and radiation detection systems (2).

We obtained radiolabeled antibody biodistribution data in patients with low- or intermediate-grade non-Hodgkin lymphoma using tracer infusions of 111In-ibritumomab tiuxetan (185 MBq) after 250 mg/m2 of rituximab. Measurements were made by quantitative imaging at 5 times on each patient to determine the uptake and biologic retention for radiolabeled antibody in the major organs and tissues. Because 90Y is a pure β-emitter, it cannot be imaged accurately or conveniently in the patient. We assumed that the biodistribution of the trace-labeled 111In-antibody represented the biodistribution of 90Y-antibody in the cancer patient.

Quantitative Imaging

Whole-body scans with conjugate views were obtained to assess whole-body and organ activity over time. Conjugate-view scintillation camera images were acquired immediately after 111In-ibritumomab tiuxetan infusion (time, 0), and again at 4–6 h and on days 1, 3, and 6 through a medium-energy collimator in a 256 × 1,024 acquisition matrix using photopeak settings of 172 and 247 keV with 15% windows. Our objective was to measure the 111In radioactivity in organs at each imaging time point. Imageable source organs included the kidneys, liver, lungs, spleen, heart, red marrow, and testes.

Figure 1 shows anterior and posterior views at 4 h, day 3, and day 6 after infusion of a non-Hodgkin lymphoma patient who was imaged using 111In-ibritumomab tiuxetan. These time-sequential images show decreasing radioactivity in normal organs while radioactivity in disease-containing, enlarged lymph nodes becomes increasingly prominent.

FIGURE 1. 
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1. 

Anterior (A) and posterior (P) views of a non-Hodgkin lymphoma patient imaged using 111In-ibritumomab tiuxetan at 4 h, day 3, and day 6 after infusion, showing decrease in normal organ activity over time with increase in lymph node prominence. (Courtesy of the University of Alabama at Birmingham.)

Using standard methods for quantitative imaging (18–21), we obtained the geometric mean of the planar anterior and posterior counts to determine the 111In activity in each region for which both anterior and posterior images showed activity above background. For the kidneys and testes, in which uptake was often observed only on posterior or anterior images, respectively, only 1 view was used. Images at early times after injection were acquired at a scan speed of 10 cm/min, and later images were acquired at decreasing speeds; the final image was acquired at 5 cm/min. Each patient's position on the imaging table and the vertical positions of the camera detectors were recorded for the first imaging session; the same positions were applied throughout the sequential imaging studies to ensure reproducible detector-to-patient positioning. A calibrated 111In source (1.85 MBq in 10 mL of water) was included at each image session to correct for potential system drift and to convert image region-of-interest (ROI) counts to units of radioactivity (adjusted with size effect). Counts in selected ROIs were corrected for background. The thickness of the background region was equivalent, after accounting for photon attenuation, to the overlapped background tissues in the organ from the anterior and posterior views.

The importance of attenuation correction in quantitative imaging has long been recognized (20,21). We obtained attenuation-correction factors using 57Co transmission images, with and without the patient on the imaging table, according to methods previously described (22). For example, the attenuation correction factor for the liver was determined by:MathEq. 1where Npt and Nnopt represent the liver ROI counts in the 57Co transmission images with and without the patient, respectively. Equation 1 corrects for energy differences between 57Co and 111In. The values for μ57Co,liver and μ111In,liver were determined experimentally from liver phantom studies (22). We measured the effective μ values individually using organ phantoms for 57Co and 111In rather than merely assuming that the ratio of μ111In to μ57Co was 1.0 for flood sources. Phantom sizes and depths were selected to mimic sizes and depths for the liver, spleen, kidneys, and tumors in patients.

When substantial amounts (>25%) of the right kidney were overlapped by the liver in the planar view, only the left kidney region was quantified, and the result was doubled to estimate the total kidney uptake. Although the mean contribution to the liver from the overlapping right kidney was 1.6% (range, 0.2%−4.5%), the activity of the overlapping portion of the right kidney was excluded. The remainder-tissue activity was the difference between the whole-body activity and the combined activities of all measured organs. The uptake of 111In-labeled antibody was expressed as percentage of administered activity at each imaging time point.

For a source location that can be visualized only in a single view, a previous study suggested that accurate source quantification could be achieved using single-view techniques and an effective point-source method (20):MathEq. 2where Isource represents the background-corrected counts per second in the source ROI for the single-view image, and μeff is the effective linear attenuation coefficient determined using a 150-mL phantom for the kidneys and spleen (or 50 mL for the lumbar vertebrae) (22). The source depth d is determined from CT images, and c is the camera system calibration factor (counts/s/activity) for that source. Because the image acquisition protocol of this study was similar to that of the original phase I/II ibritumomab tiuxetan trial (23), image counts in a scatter window were not collected and thus scatter correction was not applied. Phantom studies used 111In to simulate organ uptake in the presence of 111In background concentrations. With high tissue backgrounds, we found relatively little gain from scatter correction, compared with photon attenuation and background correction.

Organ Volumetrics Using Patient-Specific Measurements

CT images were obtained to associate each patient-specific scintillation camera activity value with a patient-specific organ mass to increase the accuracy of the dose estimate. The liver, spleen, kidney, and heart volumes were manually defined by individual slice contour drawings on 3- to 5-mm-thick slices. Lung volumes were determined using a contrast-difference edge-detection method with manual correction for air in the main bronchi. A nominal tissue density of 1 g/cm3 was used for soft tissues except for the lungs, where we assumed the lung density to be 0.26 g/cm3 (24). The heart region was defined as extending below the level in which the pulmonary trunk branches into the left and right pulmonary arteries, because none of the heart chambers extends above the pulmonary arteries. We assumed that the activity measured in the heart was associated with circulating radiolabeled antibody rather than with uptake in the heart muscle. Testicle volumes were not determined because they were out of the CT field of view; red marrow volumes also were not determined. We imaged the second, third, and fourth lumbar vertebral bodies (L2–L4) to directly measure radiolabeled antibody uptake in red marrow space (25).

Source Organ Residence Times

We defined a source organ as any organ or tissue for which measurement data were available for calculating internal dose. Decay-corrected measurement data for each source organ, tissue, the whole body, and remainder tissues were converted to percentage administered activity. We plotted the time–activity curves for each source organ in each patient and fit the data using least-squares linear regression to an exponential function. The organ time–activity curves were fit to a single exponential when the correlation coefficient was good (r ≥ 0.98) but otherwise were fit to a biexponential function. For organs or tissues with delayed uptake followed by exponential clearance, as is typical of the kidneys and testes, we fit the time–activity curves to a biexponential uptake–washout equation:MathEq. 3where x is time after administration (h). The area under the time–activity curve is proportional to the residence time (Bq-h/Bq), an input value to dosimetry software. Residence times were calculated for the whole body, each source organ, and the remainder tissues by integrating the area under each time–activity curve represented by the best-fit exponential and dividing by the administered activity. The remainder-tissue activity was determined by subtracting the sum of the measured source organ activities from the whole-body activity at each measurement time.

Absorbed-Dose Calculations

The OLINDA-EXM software (9) implements the calculational schema recommended by the SNM MIRD Committee (10). The residence times based on the 111In measurements and area-under-the-curve analysis for each of the major source organs and remainder were input into OLINDA-EXM to calculate organ-absorbed doses (9,13). OLINDA-EXM also allows entry of user-specified organ volumes and patient weights.

RESULTS

Radiation Absorbed Dose per Administered Activity

Radiation absorbed doses per unit administered activity (mGy/MBq ± SD) were calculated for each of the 10 patients. Tables 1 and 2 summarize the mean absorbed doses for 10 lymphoma patients from administered 111In-ibritumomab tiuxetan and 90Y-ibritumomab tiuxetan, respectively. Results in Tables 1 and 2 were reduced to 3 significant figures.

Radiolabeled Antibody Uptake and Retention Half-Times

After infusion, the 111In-labeled antibody distributed via blood circulation to the major organs, tissues, and tumor masses. Table 5 summarizes the measured uptakes soon after infusion and the mean clearance half-times for the major organs or tissues, the remainder tissues, and the whole body from the decay-corrected measurement data. Table 5 also gives the mean residence times calculated from the effective retention data (not decay-corrected) for each source organ, tissue, and the remainder.

View this table:
  • View inline
  • View popup
TABLE 5

Biologic (Decay-Corrected) Data for 111In-Ibritumomab Tiuxetan

Values in Table 5 suggest single exponentials that may be plotted semilogarithmically. Figure 2 shows the data from Table 5 plotted as single lines without error bars to show the relative biodistribution (uptake and retention) of 111In-ibritumomab tiuxetan in the lymphoma patient.

FIGURE 2. 
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2. 

Biodistribution of 111In-ibritumomab in whole body and major organs with time after infusion. These decay-corrected (biologic) data plotted semilogarithmically represent mean values for 10 patients in this study (Table 5) to which single-exponential retention functions were applied.

DISCUSSION

Internal radiation doses for 111In- and 90Y-ibritumomab tiuxetan were obtained from data on the biokinetics of trace-labeled 111In-antibody tracer in 10 lymphoma patients. Measurement data were obtained independently at 3 medical centers using scintillation camera acquisitions for 5 time points after administration of 111In-ibritumomab tiuxetan. All patients in this study exhibited normal biodistribution patterns that would allow them to receive a therapeutic infusion of ibritumomab tiuxetan. Altered biodistribution, such as excess uptake in the kidneys (previously demonstrated by others (26) in a small percentage of patients), was not observed in this study.

Use of 111In to Predict 90Y Biodistribution

Preclinical studies by others showed that the biodistribution of 111In antibody correlates with 90Y antibody biodistribution (1,26). Therefore, it is common practice to use 111In-ibritumomab measurement data to predict the biodistribution of 90Y-ibritumomab. The correlation is only partly correct, however, because partial disassociation of 90Y and 111In from the immunoconjugate may occur in vivo. Some of the free 90Y deposits on bone surfaces, and some of the 111In preferentially goes to the testes because of the uptake of indium by germ cells (27). Quality control allowed less than 2% unbound 111In in the injection solution. We did not measure the unbound fraction in serum after injection. For dosimetry calculations, we assumed that the biodistributions of 111In- and 90Y-labeled antibody were equivalent, recognizing that this assumption may lead to underestimates of the 90Y dose to bone surfaces and red marrow and to overestimates of 90Y dose to the testes.

Patient-Specific Organ Mass for Dosimetry

Absorbed dose is inversely proportional to target organ mass. We determined organ masses in each patient for the spleen, liver, kidneys, and lungs by CT. We observed wide variability in organ masses. In lymphoma patients, it is not uncommon for the spleen to be 2–10 times larger than that of the standard reference adult model (183 g). Spleen sizes in these 10 patients ranged from 193 to 697 g (mean ± SD, 369 ± 155 g). Liver sizes ranged from 1,169 to 2,396 g (mean ± SD, 1,679 ± 335 g). Total kidney mass for both kidneys ranged from 221 to 529 g (mean ± SD, 439 ± 99 g). We observed a trend for larger organs in male patients for each organ, with some overlap in values for men and women for all organs except the lungs; female lungs ranged from 2,131 to 4,071 cm3 (554–1,058 g; mean ± SD, 806 ± 231 g) and male lungs ranged from 4,895 to 6,836 cm3 (1,273–1,777 g; mean ± SD, 1,633 ± 219 g). Reference values for the 73.7-kg adult (9) were assumed for the testes (39.1 g), heart wall (316 g), and red marrow (1,120 g). We assumed that lumbar vertebral regions L2–L4 contained 6.66% of the red marrow mass (28).

Limiting Organ Dose

Radiation dose to a critical organ or tissue usually limits the amount of radioactivity that can be safely administered in radioimmunotherapy. Depending on the disease and treatment, critical organs may be the red marrow, liver, lungs, kidneys, stomach, or intestinal tract. We assessed dose to these organs and 18 others and also to the whole body to determine the organ or tissue likely to receive the highest absorbed dose. Radiation absorbed doses reported in this article (Tables 1 and 2) represent the arithmetic average (mean) and SD for each organ and the whole body; the mean is the expectation value of a distribution. We also determined the median values to directly compare our results with the estimated absorbed doses provided in the current ibritumomab tiuxetan package insert values (6) (Zevalin package insert information is subject to change without notice and is periodically updated by the product manufacturer) and with the results of Cremonesi et al. (7), which were published as median and range. The mean and median of a distribution are equivalent if the distribution is normal. For each organ or tissue or the whole body, the absorbed doses in our dataset were found to be lognormally distributed.

In this study, the organs receiving the highest absorbed dose from 90Y-ibritumomab tiuxetan were the spleen (mean, 4.65 mGy/MBq; median, 4.31 mGy/MBq), liver (mean, 3.64 mGy/MBq; median, 3.14 mGy/MBq), and red marrow (mean, 2.73 mGy/MBq; median, 2.39 mGy/MBq). For comparison, the package insert values (6) are a median of 9.4 mGy/MBq in the spleen, a median of 4.8 mGy/MBq in the liver, a median of 1.3 mGy/MBq in the red marrow, and a median of 2.4 mGy/MBq in the kidneys. Our results (median values) for these organs were 46% of the current product package insert value for the spleen, 65% of the package insert value for the liver, and 184% of the package insert value for red marrow and 2,400% of the package insert value for the kidneys. In our study, the average lung dose was 0.761 mGy/MBq (median, 0.597 mGy/MBq), which is 30% of the package insert (median) value of 2.0 mGy/MBq.

Cremonesi et al. (7) estimated the median absorbed doses for 90Y-ibritumomab tiuxetan using methods (method A: patient-specific organ volumetrics, image correction, and OLINDA-EXM) similar to those used in our study. However, some methods were different: Cremonesi et al. (7) calculated red marrow doses using blood concentration data and the method of Sgouros et al. (29) to determine the residence times (τ) for marrow, whereas we used the blood data for other purposes and calculated red marrow doses by directly measuring the 111In activity in lumbar vertebral bodies L2–L4 at 5 time points after injection (25). We preferred the direct imaging method because marrow uptakes in the lumbar vertebrae were clearly visualized in patients. Table 6 compares the median absorbed doses reported in our study with the current package insert values (6) and the values reported by Cremonesi et al. (7) for selected organs and tissues and the whole body.

View this table:
  • View inline
  • View popup
TABLE 6

Comparison of Median Absorbed Doses per Unit Administered Activity from 90Y-Ibritumomab Tiuxetan for Selected Organs and Tissues

Kidney Dose

In this study, the kidneys received a mean absorbed dose of 2.44 mGy/MBq (median, 2.44 mGy/MBq) from 90Y-ibritumomab tiuxetan. However, the current package insert value (6) indicates a dose to the kidneys of 0.1 mGy/MBq. Our median dose for the kidneys is 24.4 times the package insert value (Table 6) but similar to the median dose of 1.7 mGy/MBq reported by others (7). The differences may be due to our choice of the kidneys as a source organ, whereas the kidneys were likely assumed to be among the remainder tissues in the package insert studies (1–5). Prior dose estimates for 111In-ibritumomab tiuxetan and 90Y-ibritumomab tiuxetan by others may have not fully accounted for photon attenuation; kidney doses were reported to be less than those for the total body, even though activity from kidneys was prominent in the images.

Liver Dose

In this study, we found an average liver dose of 3.64 mGy/MBq (median, 3.1 mGy/MBq) from 90Y-ibritumomab tiuxetan. These values compare (Table 6) with the package insert median of 4.8 mGy/MBq (6) and the 2.8 mGy/MBq reported by Cremonesi et al. (7).

Lung Dose

In this study, we found an average lung dose of 0.761 mGy/MBq (median, 0.60 mGy/MBq; Table 2) from 90Y-ibritumomab tiuxetan. These values compare (Table 6) with the package insert median of 2.0 mGy/MBq (6) and the 1.7 mGy/MBq reported by Cremonesi et al. (7). Prior dosimetry studies (6,7) assumed a lung mass of 1,000 g (reference man) or 800 g (reference woman) (9). Average lung mass in this 10-patient group was 1,182 g, almost 12% greater than the reference man lung mass. Mean photon attenuation in the lungs was 0.60 (range, 0.45–0.73) of the liver attenuation values.

Heart Wall Dose

We calculated a median absorbed dose to the heart wall from circulating 90Y-ibritumomab of 1.01 mGy/MBq. This value is 35% of the dose (2.9 mGy/MBq) given in the ibritumomab tiuxetan package insert (6) for 90Y for the heart wall. The differences in absorbed dose to the heart wall reported by others may be due to methods used to evaluate the activity associated with the heart ROI. In our study, we defined the heart activity as a heart ROI, including blood contents, without including major vessels above the pulmonary artery. We also found large variations in heart size. Other investigators may have included a portion of major vessels in their ROI or may not have specifically measured the heart as a major source organ.

Testis Dose

We observed localization of 111In in the testes. None of the patients was known to have testicular disease. Because we had not seen this phenomenon with 131I-labeled antibodies, we attributed the observed uptake to disassociated 111In in testicular germ cells. Direct measurements after an 111In-chloride injection show simple homogeneous biodistribution throughout the body in adults (27), together with an enhanced 111In bioconcentration in the testes by a factor of about 3.6. The 111In-ibritumomab tiuxetan uptake and retention half-times that we measured in the testes were more variable from one patient to another than for any other organ in our study.

In the earliest package insert after drug approval, the median 90Y-ibritumomab dose to the testes was reported as 9.1 mGy/MBq and appears to have been a gross overestimate. The testis doses recalculated by the same investigators with different methods resulted in an estimated median value of 2.8 mGy/MBq, or about a factor of 3 smaller (2). Using a background-corrected anterior ROI with attenuation for depth, Shen et al. (30) calculated a median testicular dose of 2.4 mGy/MBq, which compares well with the median 90Y testicular dose of 1.8 mGy/MBq and average value of 2.16 mGy/MBq in the present study. Measured uptakes and retention half-times of 111In in the testes were more variable than for other normal organs when studied with 111In-CYT-356, B72.3, and CC49 fusion (30–32).

Intestinal Wall Dose

We did not observe consistent, measurable uptakes of 111In-ibritumomab in the small or large intestines (17). Heterogeneous patches of activity are frequently seen in the bowel, but the activity of these patches has not been readily quantifiable. Such uptake represents Peyer patches (normal lymphoid areas in the bowel) in most patients. Other investigators estimate that about 7% of administered 90Y is excreted in the urine within 10 d and that a lesser amount is excreted in the feces because urinary excretion correlates with decreasing whole-body radioactivity (6). Assuming the intestines as remainder tissue and that very little activity cleared in bowel contents, we calculated a median absorbed dose of 0.360 mGy/MBq for the upper large, lower large, and small intestines, in close agreement with a median value of 0.4 mGy/MBq reported by Cremonesi et al. (7). Other investigators assigned residence times to activity in the wall of the large intestines (2,24) rather than to bowel contents, resulting in product package insert values (6) of 3.6 mGy/MBq or 4.7 mGy/MBq (depending on the version of insert used).

Whole-Body Dose

In our study, the whole body received a mean absorbed dose of 0.587 mGy/MBq (median, 0.552 mGy/MBq). This result is similar to the current package insert value of 0.5 mGy/MBq (6). On average, our results show that a whole-body absorbed dose of 0.75 Gy would be delivered by infusion of about 1.28 GBq of 90Y-ibritumomab tiuxetan.

Effect of Attenuation Correction on Dose Estimation

In the 2001 dosimetry analyses for ibritumomab tiuxetan prepared for regulatory review (6), organ and tissue activities were determined using geometric mean ROI counts as a fraction of total counts from the whole body without explicit attenuation correction. This assumption was based on image quantification using a 250-mL source phantom and the baboon liver and spleen (33). In our study, we used an explicit attenuation-correction method based on transmission scan or transmission measurement and patient-specific organ masses. To determine the improvement in activity measurement after attenuation correction, we calculated radiation doses to the liver with and without attenuation correction. The overall effect of attenuation correction, compared with the nonattenuated approach, was to reduce the absolute activity in the liver, on average, by a factor of 2.53. For 90Y in the liver, this factor reduced the liver dose by approximately the same factor, showing the overall importance of attenuation correction for internal organ dosimetry.

CONCLUSION

Radiation absorbed-dose calculations provide valuable information for determining the amount of a therapy radiopharmaceutical that may be delivered without exceeding a dose-related toxicity in any normal organ or tissue. This article summarizes the mean and median absorbed doses and compared the medians with values in the current product package insert (6) and those reported by Cremonesi et al. (7).

We studied the biokinetics and dosimetry of 111In- and 90Y-ibritumomab tiuxetan in 10 patients (6 men and 4 women) with non-Hodgkin lymphoma. We measured the mean initial organ uptake fractions of administered 111In-labeled antibody (at time 0 h) and the mean biologic retention half-times of 111In-labeled antibody in the kidneys, liver, lungs, spleen, heart contents, red marrow, testes, and whole body. The dosimetry was customized using patient-specific quantitative imaging, organ volumetrics from CT scans, and detailed analysis of attenuation factors for several source organs. After integrating the areas represented by the time–activity curves for the major organs, we calculated radiation absorbed doses per unit administered activity for both 111In- and 90Y-labeled antibody in 24 organs and the whole body for each patient. For 90Y, we found that the spleen and liver received the greatest absorbed doses (mean, 4.65 and 3.64 mGy/MBq, respectively). We calculated red marrow doses by measuring the activity in selected lumbar (L2–L4) spaces. The mean absorbed dose to red marrow was 2.73 mGy/MBq, and the mean total-body dose was 0.587 mGy/MBq.

Our dose estimates for the total body and most normal organs are similar to those reported previously by others for various 111In-labeled murine monoclonal antibodies. However, we found substantial differences between our results and the current or previous package insert values. Compared with the current package insert, we found differences in median absorbed dose by multiples of 24 in the kidneys, 1.8 in the red marrow, 0.65 in the liver, 0.077 in the intestinal wall, 0.30 in the lungs, 0.46 in the spleen, and 0.34 in the heart wall.

The wide range of doses calculated for various organs by investigators using patient-specific methods indicates the importance of patient-specific dosimetry for planning and conducting radionuclide therapy procedures. The kidneys and testes are 2 organs of particular interest because of the greater differences in radiation absorbed dose that we found, compared with prior studies, including those doses given in the ibritumomab tiuxetan package inserts. We attribute differences in dose estimates to quantitative imaging techniques and patient-specific organ dosimetry. This work shows that dosimetry approach, assumptions, and choice of parameters can substantially affect the calculated doses. Careful background subtraction, attenuation correction, use of patient-specific organ masses rather than standard phantom values, and use of updated calculational software can significantly strengthen the overall accuracy of internal radiation dose estimates.

Acknowledgments

We appreciate the suggestions provided by past MIRD Committee Chair Stephen R. Thomas. Committee tasks are supported by the Society of Nuclear Medicine. We thank Biogen Idec Inc., and specifically Christine A. White and the late Richard Belanger, for permission to use data from protocol UAB 0127 for this analysis. We also thank the protocol principal investigators, Andres Forero (University of Alabama at Birmingham), Gregory A. Wiseman (Mayo Clinic), and Susan J. Knox (Stanford University), who contributed patient data for this study. Manuscript preparation was supported by the U.S. Department of Energy under contract DE-AC05-76RL01830 with Pacific Northwest National Laboratory.

Footnotes

  • In collaboration with the SNM MIRD Committee: Wesley E. Bolch, Darrell R. Fisher, Roger W. Howell, Ruby F. Meredith, George Sgouros (Chair), Barry W. Wessels, and Pat Zanzonico

  • This report was approved by the MIRD Committee on November 13, 2008.

  • COPYRIGHT © 2009 by the Society of Nuclear Medicine, Inc.

References

  1. 1.↵
    Wiseman GA, Leigh BR, Erwin WD, et al. Radiation dosimetry results from a phase II trial of ibritumomab tiuxetan (Zevalin) radioimmunotherapy for patients with non-Hodgkin's lymphoma and mild thrombocytopenia. Cancer Biother Radiopharm. 2003;18:165–178.
    OpenUrlCrossRefPubMed
  2. 2.↵
    Wiseman GA, Leigh BR, Erwin WD, et al. Additional radiation absorbed dose estimates for Zevalin radioimmunotherapy. Cancer Biother Radiopharm. 2003;18:253–258.
    OpenUrlCrossRefPubMed
  3. 3.
    Wiseman GA, Kommehl E, Leigh B, et al. Radiation dosimetry results and safety correlations from 90Y-ibritumomab tiuxetan radioimmunotherapy for relapsed or refractory non-Hodgkin's lymphoma: combined data from 4 clinical trials. J Nucl Med. 2003;44:465–474.
    OpenUrlAbstract/FREE Full Text
  4. 4.
    Wiseman GA, Leigh B, Erwin WD, et al. Radiation dosimetry results for Zevalin radioimmunotherapy of rituximab-refractory non-Hodgkin lymphoma. Cancer. 2002;94(4, suppl):1349–1357.
    OpenUrlCrossRefPubMed
  5. 5.↵
    Wiseman GA, White CA, Sparks RB, et al. Biodistribution and dosimetry results from a phase III prospectively randomized controlled trial of Zevalin radioimmunotherapy for low-grade, follicular, or transformed B-cell non-Hodgkin's lymphoma. Crit Rev Oncol Hematol. 2001;39:181–194.
    OpenUrlPubMed
  6. 6.↵
    Zevalin® prescribing information [package insert]. Seattle, WA: Cell Therapeutics, Inc.; 2008. Available at: www.zevalin.com/pdf/Zevalin_PI_website.pdf. Also available at: http://www.fda.gov/cder/foi/label/2002/ibriide021902LB.pdf. Accessed February 20, 2009.
  7. 7.↵
    Cremonesi M, Ferrari M, Grana CM, et al. High-dose radioimmunotherapy with 90Y-ibritumomab tiuxetan: comparative dosimetric study for tailored treatment. J Nucl Med. 2007;48:1871–1879.
    OpenUrlAbstract/FREE Full Text
  8. 8.↵
    Assié K, Dieudonné A, Gardin I, Buvat I, Tilly H, Vera P. Comparison between 2D and 3D dosimetry protocols in 90Y-ibritumomab tiuxetan radioimmunotherapy of patients with non-Hodgkin's lymphoma. Cancer Biother Radiopharm. 2008;23:53–64.
    OpenUrlCrossRefPubMed
  9. 9.↵
    Stabin M, Sparks RB, Crowe E. OLINDA/EXM: the second-generation personal computer software for internal dose assessment in nuclear medicine. J Nucl Med. 2005;46:1023–1027.
    OpenUrlAbstract/FREE Full Text
  10. 10.↵
    Loevinger R, Budinger TF, Watson EE. MIRD Primer for Absorbed Dose Calculations. Rev ed. Reston, VA: Society of Nuclear Medicine; 1999.
  11. 11.↵
    Chinn P, Leonard J, Rosenberg J, Hanne N, Anderson D. IDEC-Y2B8: a 90Y-labeled anti-CD20 monoclonal antibody conjugated to MX-DTPA, a high-affinity chelator for yttrium [abstract]. Proc Am Assoc Cancer Res. 1999;40:574.
    OpenUrl
  12. 12.↵
    Cartron G, Watier H, Golay J, Solal-Celigny P. From the bench to the bedside: ways to improve rituximab efficacy. Blood. 2004;104:2635–2642.
    OpenUrlAbstract/FREE Full Text
  13. 13.↵
    Stabin MG, da Luz LC. New decay data for internal and external dose assessment. Health Phys. 2002;83:471–475.
    OpenUrlCrossRefPubMed
  14. 14.↵
    Bray L, Wester DW, inventors; Battelle Memorial Institute, assignee. Method of separation of yttrium-90 from strontium-90. U.S. patent 5,512,256. April 30, 1996.
  15. 15.↵
    Khazaeli MB. Quantitation of mouse monoclonal antibody and human anti-mouse antibody response in serum of patients. Hybridoma. 1989;8:231–239.
    OpenUrlPubMed
  16. 16.↵
    Press OW, Appelbaum F, Ledbetter JA, et al. Monoclonal antibody 1F5 (anti-CD20) serotherapy of human B cell lymphomas. Blood. 1987;69:584–591.
    OpenUrlAbstract/FREE Full Text
  17. 17.↵
    Press OW, Eary JF, Appelbaum FR, et al. Radiolabeled-antibody therapy of B-cell lymphoma with autologous bone marrow support. N Engl J Med. 1993;329:1219–1224.
    OpenUrlCrossRefPubMed
  18. 18.↵
    DeNardo GL, DeNardo SJ, Macey DJ, Mills SL. Quantitative pharmacokinetics of radiolabeled monoclonal antibodies for imaging and therapy in patients. In: Srivastava SC, ed. Radiolabeled Monoclonal Antibodies for Imaging and Therapy. New York, NY: Plenum; 1988:293–310.
  19. 19.
    Eary JF, Appelbaum FL, Durack L, Brown P. Preliminary validation of the opposing view method for quantitative gamma camera imaging. Med Phys. 1989;16:382–387.
    OpenUrlCrossRefPubMed
  20. 20.↵
    Siegel JA, Thomas SR, Stubbs JB, et al. MIRD pamphlet no. 16: techniques for quantitative radiopharmaceutical biodistribution data acquisition and analysis for use in human radiation dose estimates. J Nucl Med. 1999;40(suppl):37S–61S.
    OpenUrlAbstract/FREE Full Text
  21. 21.↵
    Thomas SR, Maxon HR, Kereiakes JG. In vivo quantitation of lesion radioactivity using external counting methods. Med Phys. 1976;03:253–255.
    OpenUrlCrossRefPubMed
  22. 22.↵
    Shen S, Forero A, LoBuglio AF, et al. Patient-specific dosimetry of pretargeted radioimmunotherapy using CC49 fusion protein in patients with gastrointestinal malignancies. J Nucl Med. 2005;46:642–651.
    OpenUrlAbstract/FREE Full Text
  23. 23.↵
    Wiseman GA, White CA, Stabin M, et al. Phase I/II 90Y-zevalin (yttrium-90 ibritumomab tiuxetan, IDEC-Y2B8) radioimmunotherapy dosimetry results in relapsed or refractory non-Hodgkin's lymphoma. Eur J Nucl Med. 2000;27:766–777.
    OpenUrlCrossRefPubMed
  24. 24.↵
    International Commission on Radiological Units and Measurements (ICRU). Tissue Substitutes in Radiation Dosimetry (Report 44). Bethesda, MD: ICRU; 1989. Available at: http://www.icru.org/index2.php?option=com_content&do_pdf=1&id=80. Accessed February 20, 2009.
  25. 25.↵
    Lim S, DeNardo GL, DeNardo DA, O'Donnell RT, Yuan A, DeNardo SJ. Prediction of myelotoxicity using semi-quantitative marrow image scores. J Nucl Med. 1997;38:1749–1753.
    OpenUrlAbstract/FREE Full Text
  26. 26.↵
    Conti PS, White C, Pieslor P, et al. The role of imaging with 111In-ibritumomab tiuxetan in the ibritumomab tiuxetan (Zevalin) regimen: results from a Zevalin Imaging Registry. J Nucl Med. 2005;46:1812–1818.
    OpenUrlAbstract/FREE Full Text
  27. 27.↵
    Nettleton JS, Lawson RS, Prescott MC, Morris ID. Uptake, localization, and dosimetry of 111In and 201Tl in human testes. J Nucl Med. 2004;45:138–146.
    OpenUrlAbstract/FREE Full Text
  28. 28.↵
    International Commission on Radiological Protection (ICRP). Report of the Task Group on Reference Man. ICRP Publication No. 23. Oxford, England: Pergamon Press; 1975.
  29. 29.↵
    Sgouros G. Bone marrow dosimetry for radioimmunotherapy: theoretical considerations. J Nucl Med. 1993;34:689–694.
    OpenUrlAbstract/FREE Full Text
  30. 30.↵
    Shen S, Meredith R, Duan J, et al. Testicular uptake and radiation dose in patients receiving Zevalin and Pretarget CC49Fusion protein. Cancer Biother Radiopharm. 2005; 20:110–118.
    OpenUrlCrossRefPubMed
  31. 31.
    Mardirossian G, Brill AB, Harwood SJ, et al. Radiation absorbed dose estimates for indium-111-labeled B72.3, an IgG antibody to ovarian and colorectal cancer: MIRD dose estimate report No. 18. J Nucl Med. 1998;39:671–676.
    OpenUrlFREE Full Text
  32. 32.↵
    Mardirossian G, Brill AB, Dwyer KM, et al. Radiation absorbed dose from indium-111-CYT-356. J Nucl Med. 1996;37:1583–1588.
    OpenUrlAbstract/FREE Full Text
  33. 33.↵
    van Reenen PC, Lotter MG, Heyns AD, et al. Quantification of the distribution of 111In-labelled platelets in organs. Eur J Nucl Med. 1982;7:80–84.
    OpenUrlPubMed
  • Received for publication August 21, 2008.
  • Accepted for publication November 21, 2008.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 50 (4)
Journal of Nuclear Medicine
Vol. 50, Issue 4
April 2009
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
MIRD Dose Estimate Report No. 20: Radiation Absorbed-Dose Estimates for 111In- and 90Y-Ibritumomab Tiuxetan
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
MIRD Dose Estimate Report No. 20: Radiation Absorbed-Dose Estimates for 111In- and 90Y-Ibritumomab Tiuxetan
Darrell R. Fisher, Sui Shen, Ruby F. Meredith
Journal of Nuclear Medicine Apr 2009, 50 (4) 644-652; DOI: 10.2967/jnumed.108.057331

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
MIRD Dose Estimate Report No. 20: Radiation Absorbed-Dose Estimates for 111In- and 90Y-Ibritumomab Tiuxetan
Darrell R. Fisher, Sui Shen, Ruby F. Meredith
Journal of Nuclear Medicine Apr 2009, 50 (4) 644-652; DOI: 10.2967/jnumed.108.057331
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • Acknowledgments
    • Footnotes
    • References
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • This Month in JNM
  • Errata
  • PubMed
  • Google Scholar

Cited By...

  • A Phase 1 and Biodistribution Study of ABT-806i, an 111In-Radiolabeled Conjugate of the Tumor-Specific Anti-EGFR Antibody ABT-806
  • Biokinetics of Radiolabeled Monoclonal Antibody BC8: Differences in Biodistribution and Dosimetry Among Hematologic Malignancies
  • Biodistribution and Dosimetry Results from a Phase 1 Trial of Therapy with the Antibody-Radionuclide Conjugate 177Lu-Lilotomab Satetraxetan
  • Red Marrow-Absorbed Dose for Non-Hodgkin Lymphoma Patients Treated with 177Lu-Lilotomab Satetraxetan, a Novel Anti-CD37 Antibody-Radionuclide Conjugate
  • A Preclinical Model of CD38-Pretargeted Radioimmunotherapy for Plasma Cell Malignancies
  • A Small-Scale Anatomic Model for Testicular Radiation Dosimetry for Radionuclides Localized in the Human Testes
  • Predicting Hematologic Toxicity in Patients Undergoing Radioimmunotherapy with 90Y-Ibritumomab Tiuxetan or 131I-Tositumomab
  • Impact of Rituximab Treatment on 90Y-Ibritumomab Dosimetry for Patients with Non-Hodgkin Lymphoma
  • Dosimetry of 90Y-Ibritumomab Tiuxetan as Consolidation of First Remission in Advanced-Stage Follicular Lymphoma: Results from the International Phase 3 First-Line Indolent Trial
  • Google Scholar

More in this TOC Section

  • The Use of Published Clinical Study Reports to Support U.S. Food and Drug Administration Approval of Imaging Agents
  • Variations in PET/MRI Operations: Results from an International Survey Among 39 Active Sites
  • American Society of Nuclear Cardiology and Society of Nuclear Medicine and Molecular Imaging Joint Position Statement on the Clinical Indications for Myocardial Perfusion PET
Show more Special Contributions

Similar Articles

SNMMI

© 2023 Journal of Nuclear Medicine

Powered by HighWire