Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Permissions
    • Advertisers
    • Continuing Education
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Permissions
    • Advertisers
    • Continuing Education
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Follow JNM on Twitter
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Subscribe to our RSS feeds
OtherClinical Investigations

Prospective Comparison of 3 γ-Probes for Sentinel Lymph Node Detection in 200 Breast Cancer Patients

Jean-Marc Classe, Maryse Fiche, Caroline Rousseau, Christine Sagan, François Dravet, Raphaëlle Pioud, Albert Lisbona, Ludovic Ferrer, Loic Campion, Isabelle Resche and Chantal Curtet
Journal of Nuclear Medicine March 2005, 46 (3) 395-399;
Jean-Marc Classe
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Maryse Fiche
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Caroline Rousseau
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Christine Sagan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
François Dravet
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Raphaëlle Pioud
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Albert Lisbona
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ludovic Ferrer
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Loic Campion
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Isabelle Resche
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Chantal Curtet
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

Previous reports have shown that axillary sentinel lymph node (ASLN) radiodetection allows accurate axillary staging for patients with early breast cancer. Radioguided surgery implies the use of a γ-probe to count the emitted radioactivity of marked ASLNs. Several γ-probes are commercially available, each with its own properties. The clinical impact of the type of γ-probe used for ASLN radiodetection remains to be evaluated. Methods: Three commercially available γ-probes were evaluated: a scintillator with a bismuth germanate crystal (probe A), a semiconductor with a cadmium telluride crystal (probe B), and a semiconductor with a cadmium zinc telluride crystal (probe C). Two hundred patients with early breast cancer were prospectively enrolled to undergo ASLN radiodetection and axillary lymphadenectomy. ASLN mapping consisted of injecting 99mTc-sulfur-colloid around the tumor. For each patient, sentinel lymph nodes were counted successively with the 3 probes and the sensitivity of each γ-probe was determined from ASLN residual activity. The results of detection rates and false-negative rates for each probe were compared. Results: Mean residual ASLN activity was 52 kBq (range, 0.07–189 kBq). Sensitivity was compared among the 3 probes and found to be best for probe A. The detection rate of probe A was significantly better than that of probe B (93% vs. 86%, P = 0.05) but not different from that of probe C (93% vs. 90%). No differences in false-negative rates were observed among the 3 probes. Conclusion: ASLN detection rate depends on the type of γ-probe used. Because failure to detect the ASLN leads to complete axillary lymphadenectomy, involving local morbidity and other sequelae, the type of γ-probe must be considered important for sentinel lymph node radiodetection.

  • breast cancer
  • sentinel lymph node
  • γ-probe

The sentinel lymph node concept, first described for penile cancer and melanoma, has recently been applied to early breast cancer staging (1–3). Axillary lymph node status currently remains one of the most important prognostic indicators in early breast cancer (4,5) and is of particular value in the choice of adjuvant therapy (6). If an axillary sentinel lymph node (ASLN) is detected, excised, and free of pathologic metastatic involvement, the patient is spared the morbidity of conventional axillary lymphadenectomy (7,8). Morbidity related to ASLN excision is significantly less than that related to axillary lymphadenectomy (9–11)

The ASLN may be detected using peritumoral or periareolar injection of lymphotropic products, stains, or radiotracers that map the regional lymph network of the tumor (12,13). The radiotracer approach involves the injection of a colloidal or other lymph node–avid agent labeled with a γ-emitter such as 99mTc to radioactively label the ASLN in situ. The ASLN can then be detected at surgery with a hand-held γ-probe (14).

The main criteria used to evaluate the ASLN technique are detection and false-negatives rates (12,13). Detection failure leads to axillary lymphadenectomy and potential axillary morbidity (15,16). A false-negative result means the apparent lack of involvement of the ASLN in the presence of actual involvement of the ASLN or other lymph nodes. False-negative results can lead to inadequate treatment and, ultimately, to a risk of cure failure (17). The false-negative rate can be evaluated most definitively by concomitant ASLN detection and axillary resection (18).

Several types of γ-probes are commercially available and characterized according to their principle of detection (scintillators exploiting excitation phenomena and semiconductors exploiting ionization phenomena) and their collimation (19). The basic physical performance of a γ-probe can be described by its spatial resolution, sensitivity, and counting rate linearity (20). Spatial resolution indicates the capacity of a probe to discriminate between target and background activity (21). Sensitivity characterizes the ability of a γ-probe to count a low activity (20). In the particular case of sentinel lymph node radiodetection, laboratory simulations found that the sensitivity of the γ-probe was the dominant performance factor (22).

To date, no published study has considered the impact of γ-probe sensitivity in the context of ASLN detection of early breast cancer clinically, rather than in laboratory simulations. Our working hypothesis was that the results relative to ASLN radiodetection do not differ as a function of the type of γ-probe used. We compared 3 commercially available γ-probes: a scintillator and 2 semiconductors. We first used ASLN residual activity to compare the sensitivity of these 3 probes and then tested our hypothesis on a prospective clinical series of 200 patients with invasive early breast cancer, in accordance with the legal recommendations relative to the rules of clinical research.

MATERIALS AND METHODS

γ-Probes

The 3 probes tested were Modelo 2 (probe A; Damri), a scintillator with a bismuth germanate (BGO) crystal, and the 2 semiconductors Navigator (probe B; Tyco), with a cadmium telluride (CdTe) crystal, and Neoprobe (probe C; Breast Care), with a cadmium zinc telluride (CZT) crystal. The main features of these probes are indicated in Table 1.

View this table:
  • View inline
  • View popup
TABLE 1

Main Features of the 3 γ-Probes

Clinical Series

From June 1999 to September 2001, a prospective series of 200 patients treated for invasive early breast cancer underwent ASLN detection with the 3 probes and concomitant complementary axillary lymphadenectomy. Each patient gave signed informed consent, in accordance with the legal recommendations relative to the rules of clinical research. The inclusion criteria were preoperative diagnosis of invasive early breast carcinoma, clinical tumor size of less than 3 cm (T0, T1, T2 < 3 cm), no palpable axillary node (N0), an indication for initial surgical treatment, and the signed informed consent form. Exclusion criteria were pregnancy, lack of preoperative diagnosis, and previous tumor excision or neoadjuvant chemotherapy.

The radiodetection method consisted of the injection of unfiltered 99mTc-labeled rhenium sulfur colloids (Nanocis; CIS Bio International) superficially within the parenchyma around the tumor. An activity of 30–40 MBq in 2 × 0.1 mL of physiologic serum was used if the injection was performed on the evening before surgery, or 20–30 MBq in 2 × 0.1 mL if performed on the morning of surgery. Intraoperative detection was performed with the 3 tested probes: probe A and probe B for all patients plus probe C for the last 140 patients. The probes were always used in the same order: A, then B, then C. Probes A and C were used with an external detachable collimator, and probe B had an internal integrated collimator. The intraoperative detection protocol included successive counts of the chest wall (defined as background) and counts of each ASLN with each of the 3 probes.

The surgical technique systematically involved breast tumor excision, followed by a horizontal axillary incision to detect and remove 1 or more ASLNs, and a complementary functional axillary lymphadenectomy of the first 2 Berg levels.

A positive finding of an ASLN was defined as the intraoperative detection of a number of counts per second that was at least twice the background level.

The sensitivity of a probe is defined as the number of counts recorded by the probe per unit of source activity and is expressed in counts per second per kilobecquerel (20). To evaluate the sensitivity of the 3 γ-probes tested, immediately after surgical resection we used a scintillation well counter (COBRA II model 85003; Packard) calibrated with a 99mTc source to measure the residual activity of 72 ASLNs previously counted with the 3 probes. The ASLN activity used to calculate the probe sensitivities was decay corrected in accordance with the technetium period. Residual activity was expressed in counts per minute per kilobecquerel. Direct measurement of ASLN activity in a scintillation well counter allowed determination of the amount of residual activity in the ASLN relative to the injected dose. The sensitivity of each probe was determined by comparing the number of counts obtained with each probe during surgery with the residual activity of each ASLN. The results for 28 nodes from patients injected the morning of surgery and 44 nodes from patients injected the evening before surgery were considered.

Pathologic Analysis

No intraoperative histopathologic examination was performed. Each node was completely embedded in paraffin and cut into 2-mm-thick sections perpendicular to its long axis. Further analysis differed for ASLN and axillary lymphadenectomy. ASLNs were cut into ten 4-μm sections. Standard hematoxylin-phloxine-saffron staining was performed on levels 1, 4, and 7. In the absence of detectable metastasis or micrometastasis on these first sections, immunohistochemical labeling was performed on the 3 intermediary levels. A micrometastasis was defined as a metastasis less than or equal to 0.2 cm in diameter. For each node from the lymphadenectomy, one 4-μm section was cut from each block and stained with hematoxylin-phloxine-saffron but no immunohistochemistry was performed.

Definitions

The detection rate was defined as the number of patients whose ASLNs were identified by γ-probe counting relative to the total number of patients in the study. This rate was determined for each of the 3 probes. Considering only patients with at least 1 detected ASLN, the false-negative rate was defined as the ratio of the number of patients whose ASLNs were not involved but who had 1 or more involved nonsentinel axillary nodes in concomitant axillary lymphadenectomy, to the number of patients with 1 or more lymph nodes involved, whether sentinel or not. This rate was determined for each of the 3 probes.

Statistical Method

The χ2 test was used, with an α-risk of 5%, to compare detection and false-negative rates for the 3 probes.

RESULTS

Population Characteristics

The characteristics of the patients are indicated in Table 2. The T of TNM staging was used to distinguish the groups by clinical size of tumor.

View this table:
  • View inline
  • View popup
TABLE 2

Clinical Characteristics of the 200 Patients

ASLN Residual Activity and γ-Probe Sensitivity

The mean ASLN activity was 52 kBq (range, 0.07–189 kBq), as indicated in Table 3. Whether injection was performed the morning of the operation or the evening before, the percentage of injected activity in the ASLN was 0.15% of the injected dose (Table 3). The sensitivity of the probes is indicated in Table 4. Sensitivity was comparable for probes B and C. The sensitivity of probe A was 6-fold higher than that of probe B or probe C when injection was performed the morning of the operation and 4-fold higher when performed the evening before (Table 4).

View this table:
  • View inline
  • View popup
TABLE 3

Residual Activity in ASLNs as Function of Dose Injected Around Breast Tumor

View this table:
  • View inline
  • View popup
TABLE 4

Count Efficiency of the 3 γ-Probes as Function of Time Between Injection and Surgical Incision

Detection Rate

The radiodetection rates per probe are indicated in Table 5. The detection rate was significantly better with probe A than with probe B (93% vs. 86%, respectively; P < 0.05) (Table 5).

View this table:
  • View inline
  • View popup
TABLE 5

Radiodetection Rates with the 3 γ-Probes

False-Negative Rate

Table 6 indicates the false-negative rate for each probe. No significant differences in false-negative rates were found among the 3 γ-probes tested (Table 6). For each patient with at least 1 ASLN detected and at least 1 lymph node involved, whether sentinel or not, the hottest ASLN was not involved in 12 cases with probe A or B and in 6 cases with probe C. Table 7 indicates the false-negative-rate for each probe if, with the same ASLN definition, only the hottest ASLN was analyzed (Table 7).

View this table:
  • View inline
  • View popup
TABLE 6

False-Negative Rates for the 3 γ-Probes

View this table:
  • View inline
  • View popup
TABLE 7

False-Negative Rates for the 3 γ-Probes If only Hottest ASLN Was Excised

DISCUSSION

In the current study, a clinical comparison of 3 γ-probes (BGO scintillator and CZT and CdTe semiconductors) showed that they differ in sensitivity and detection rates for sentinel lymph nodes.

Whereas a radioactive source emits its γ-rays in a 4π solid angle, a γ-probe detects only a small fraction of them along its axis. Sensitivity, which indicates the efficiency of a probe in detecting and counting radiation, corresponds to the number of counts per second per unit of source activity expressed in kilobecquerels. Our results showed that residual activity in the ASLN was approximately 50 kBq, corresponding to 0.15% of the injected dose (Table 3). It has been shown that the sensitivity of a scintillator is better than that of a semiconductor (23–25) and that the sensitivity of a CZT semiconductor is better than that of a CdTe semiconductor (21). In our experiment, the BGO scintillator (probe A) counted 4 times as much radioactivity as did the 2 semiconductors (probes B and C) for patients injected the evening before and 7 times as much for patients injected the morning of the operation (Table 4).

Spatial resolution and sensitivity differ depending on whether the probe is collimated. The purpose of collimation is to maintain maximum precision for axial localization of the target by counting only radiation from the target itself (25,26). Generally speaking, collimation improves spatial resolution but reduces sensitivity (20–23). For our comparisons, we used 3 commercially available collimated γ-probes without any modification: a scintillator with a BGO crystal, a semiconductor with a CdTe crystal, and a semiconductor with a CZT crystal (Table 1).

Our results showed that the sensitivity of the 3 γ-probes differed. On the basis of a prospective clinical series of 200 patients, these differences in physical performance were determined to have a clinical impact on the detection rate of ASLNs. The detection rate was 93% with the collimated BGO scintillator, 90% with the collimated CZT semiconductor, and 86% with the CdTe semiconductor (Table 5). This difference between the BGO scintillator and the CdTe semiconductor was statistically significant (P < 0.05) and may be an unrecognized cause of different success rates for ASLN detection. This is an important consideration, as detection failure implies that the patient will undergo axillary resection and thereby have a lower quality of life than will a patient undergoing only ASLN excision. This consideration is of particular importance for inexperienced surgeons, for whom the best of sensitivity is required to ensure detection of low-activity ASLNs.

In the current study, a comparison of the 3 probes showed no significant differences in false-negative rates (Table 6). Analysis of the relative impact of the choice of γ-probe for ASLN detection on the risk of a false-negative result would require investigation of a larger series because of the infrequency of this event (27). Isotopic activity counted in ASLNs is not predictive of metastasis (28,29). In the current study, the ASLN with the highest count was not the involved node in 20% of patient with at last 1 ASLN detected, whatever the γ-probe used (Table 7). Furthermore, a recent study has shown that false-negative results have little impact on the definitive choice of complementary treatment (30).

CONCLUSION

In summary, this study showed that the performance of γ-probes tested clinically affected ASLN detection rates. Among the γ-probes tested, the scintillator showed the best sensitivity and the best detection rate for ASLNs. The rate of ASLN detection depends not only on the skill and experience of the surgeon but also on the performance of the γ-probe. Given the low residual activity in the ASLN, sensitivity seems to be the main criterion for the choice of a γ-probe. In the current context of an international validation of ASLN detection in the surgical management of early breast cancer, it is important to consider the relative efficiency of γ-probes.

Footnotes

  • Received Apr. 12, 2004; revision accepted Aug. 5, 2004.

    For correspondence or reprints contact: Jean-Marc Classe, MD, Service Chirurgie Oncologique, Site Hôpital Nord, Boulevard J. Monod, 44805 Saint-Herblain, France.

    E-mail: jm-classe{at}nantes.fnclcc.fr

REFERENCES

  1. ↵
    Cabanas RM. An approach for the treatment of penile carcinoma. Cancer. 1977;39:456–466.
    OpenUrlCrossRefPubMed
  2. Morton DL, Wen DR, Wong JH, et al. Technical details of intraoperative lymphatic mapping for early stage melanoma. Arch Surg. 1992;127:392–399.
    OpenUrlCrossRefPubMed
  3. ↵
    Krag DN, Weaver DL, Alex JC, et al. Surgical resection and radiolocalization of the sentinel node in breast cancer using gamma probe. Surg Oncol. 1993;2:335–340.
    OpenUrlCrossRefPubMed
  4. ↵
    Ellis P, Smith I, Ashley S, et al. Clinical prognostic and predictive factors for primary chemotherapy in operable breast cancer. J Clin Oncol. 1998;16:107–114.
    OpenUrlAbstract/FREE Full Text
  5. ↵
    Moffat F, Senofsky G, Davis K, et al. Axillary node dissection for early breast cancer: some is good but all is better. J Surg Oncol. 1992;51:8–13.
    OpenUrlPubMed
  6. ↵
    Marubini E, Mariani L, Salvadori B, et al. Results of a breast-cancer-surgery trial compared with observational data from routine practice. Lancet. 1996;347:1000–1003.
    OpenUrlCrossRefPubMed
  7. ↵
    Turner RR, Ollila DW, Krasne DL, et al. Histopathologic validation of the sentinel lymph node hypothesis for breast cancer. Ann Surg. 1997;226:271–278.
    OpenUrlCrossRefPubMed
  8. ↵
    Veronesi U, Paganelli G, Viale G, et al. A randomized comparison of sentinel-node biopsy with routine axillary dissection in breast cancer. N Engl J Med. 2003;349:546–553.
    OpenUrlCrossRefPubMed
  9. ↵
    Haid A, Koberle-Wuhrer R, Knauer M, et al. Morbidity of breast cancer patients following complete axillary dissection or sentinel node biopsy only: a comparative evaluation. Breast Cancer Res Treat. 2002;73:31–36.
    OpenUrlCrossRefPubMed
  10. Temple LK, Baron R, Cody HS III, et al. Sensory morbidity after sentinel lymph node biopsy and axillary dissection: a prospective study of 233 women. Ann Surg Oncol. 2002;9:654–662.
    OpenUrlCrossRefPubMed
  11. ↵
    Schrenk P, Rieger R, Shamiyeh A, et al. Morbidity following sentinel lymph node biopsy versus axillary lymph node dissection for patients with breast carcinoma. Cancer. 2000;88:608–614.
    OpenUrlCrossRefPubMed
  12. ↵
    Guiliano AE, Kirgan DM, Guenther JM, et al. Lymphatic mapping and sentinel lymphadenectomy for breast cancer. Ann Surg. 1994;220:391–420.
    OpenUrlCrossRefPubMed
  13. ↵
    Krag D, Weaver D, Ashikaga T, et al. The sentinel node in breast cancer: a multicenter validation study. N Engl J Med. 1998;339:941–946.
    OpenUrlCrossRefPubMed
  14. ↵
    Uren RF, Howman-Giles RB, Thompson JF, et al. Mammary lymphoscintigraphy in breast cancer. J Nucl Med. 1995;36:1775–1780.
    OpenUrlAbstract/FREE Full Text
  15. ↵
    Tafra L, McMaster KM, Wihitworth, et al. Credentialing issues with sentinel lymph node staging for breast cancer. Am J Surg. 2000;180:268–273.
    OpenUrlCrossRefPubMed
  16. ↵
    Roses DF, Brooks AD, Harris MN, et al. Complications of level I and II axillary dissection in the treatment of carcinoma of the breast. Ann Surg. 1999;2:194–201.
  17. ↵
    McMasters KM, Giuliano AE, Ross MI, et al. Sentinel lymph node biopsy for breast cancer: not yet a standard of care. N Engl J Med. 1998;339:990–994.
    OpenUrlCrossRefPubMed
  18. ↵
    Orr RK, Hoehn JL, Col NF. The learning curve for sentinel node biopsy in breast cancer: practical applications. Arch Surg. 1999;134:764–767.
    OpenUrlCrossRefPubMed
  19. ↵
    Zanzonico P, Heller S. The intraoperative gamma probe: basic principles and choices available. Semin Nucl Med. 2000;30:33–48.
    OpenUrlCrossRefPubMed
  20. ↵
    Tiourina T, Arends B, Huysmans D, Rutten H, Lemaire B, Muller S. Evaluation of surgical gamma probes for radioguided sentinel node localisation. Eur J Nucl Med. 1998;25:1224–1231.
    OpenUrlCrossRefPubMed
  21. ↵
    Haigh PI, Glass EC, Essner R. Accuracy of gamma probes in localizing radioactivity: in vitro assessment and clinical implications. Cancer Biother Radiopharm. 2000;15:561–569.
    OpenUrlCrossRefPubMed
  22. ↵
    Britten AJ. A method to evaluate intra-operative gamma probes for sentinel lymph node localisation. Eur J Nucl Med. 1999;26:76–83.
    OpenUrlCrossRefPubMed
  23. ↵
    Barber HB, Barrett HH, Hickernell TS, et al. Comparison of NaI(TI), CdTe, and HgI2 surgical probes: physical characterization. Med Phys. 1991;18:373–381.
    OpenUrlCrossRefPubMed
  24. Harke H, Mandell G, Sharkey C. Surgical radiation probes: a comparison. J Nucl Med. 1988;29:881–882.
    OpenUrl
  25. ↵
    Halkar RK, Aarsvold JN. Intraoperative probes. J Nucl Med Technol. 1999;27:188–193.
    OpenUrlAbstract
  26. ↵
    Schneebaum S, Even-Sapir E, Cohen M, et al. Clinical applications of gamma-detection probes: radioguided surgery. Eur J Nucl Med. 1999;26(suppl):S26–S35.
    OpenUrl
  27. ↵
    Bergkvist L, Frisell J, Liljegren G, et al. Multicentre study of detection and false-negative rates in sentinel node biopsy for breast cancer. Br J Surg. 2001;88:1644–1648.
    OpenUrlCrossRefPubMed
  28. ↵
    Martin RC, Fey J, Yeung H, et al. Highest isotope count does not predict sentinel node positivity in all breast cancer patients. Ann Surg Oncol. 2001;8:592–597.
    OpenUrlCrossRefPubMed
  29. ↵
    Quan ML, McCready D, Temple WJ, et al. Biology of lymphatic metastases in breast cancer: lessons learned from sentinel node biopsy. Ann Surg Oncol. 2002;9:467–471.
    OpenUrlCrossRefPubMed
  30. ↵
    Nano MT, Kollias J, Farshid G, et al. Clinical impact of false-negative sentinel node biopsy in primary breast cancer. Br J Surg. 2002;89:1430–1434.
    OpenUrlCrossRefPubMed
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 46 (3)
Journal of Nuclear Medicine
Vol. 46, Issue 3
March 1, 2005
  • Table of Contents
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Prospective Comparison of 3 γ-Probes for Sentinel Lymph Node Detection in 200 Breast Cancer Patients
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Prospective Comparison of 3 γ-Probes for Sentinel Lymph Node Detection in 200 Breast Cancer Patients
Jean-Marc Classe, Maryse Fiche, Caroline Rousseau, Christine Sagan, François Dravet, Raphaëlle Pioud, Albert Lisbona, Ludovic Ferrer, Loic Campion, Isabelle Resche, Chantal Curtet
Journal of Nuclear Medicine Mar 2005, 46 (3) 395-399;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Prospective Comparison of 3 γ-Probes for Sentinel Lymph Node Detection in 200 Breast Cancer Patients
Jean-Marc Classe, Maryse Fiche, Caroline Rousseau, Christine Sagan, François Dravet, Raphaëlle Pioud, Albert Lisbona, Ludovic Ferrer, Loic Campion, Isabelle Resche, Chantal Curtet
Journal of Nuclear Medicine Mar 2005, 46 (3) 395-399;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • THIS MONTH IN JNM
  • PubMed
  • Google Scholar

Cited By...

  • Scintillation Crystal or Semiconductor {gamma}-Probes: An Open Debate
  • Reply: Scintillation Crystal or Semiconductor {gamma}-Probes: An Open Debate
  • Is the "Ideal" {gamma}-Probe for Intraoperative Radioguided Surgery Conceivable?
  • Google Scholar

More in this TOC Section

  • Diagnostic Performance of 124I-Metaiodobenzylguanidine PET/CT in Patients with Pheochromocytoma
  • Effects of Tracer Uptake Time in Non–Small Cell Lung Cancer 18F-FDG PET Radiomics
  • Nuclear Imaging for Classic Fever of Unknown Origin: Meta-Analysis
Show more CLINICAL INVESTIGATIONS

Similar Articles

SNMMI

© 2023 Journal of Nuclear Medicine

Powered by HighWire