    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Corporate & Special Sales
    • Journal Claims
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Permissions
    • Advertisers
    • Continuing Education
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Follow JNM on Twitter
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Subscribe to our RSS feeds
OtherBasic Science Investigations

Influence of Renal Function on Renal Output Efficiency

Jacob D. Kuyvenhoven, Hamphrey R. Ham and Amy Piepsz
Journal of Nuclear Medicine June 2002, 43 (6) 851-855;
Jacob D. Kuyvenhoven
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Hamphrey R. Ham
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Amy Piepsz
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

The purpose of this study was to quantify the influence of renal function on output efficiency (OE) and to evaluate factors that may modify this effect. Methods: Renograms were generated in a computer simulation model by convolution of plasma disappearance curves with artificially created retention functions. Ten plasma curves were derived from a database corresponding to renal clearances ranging from 33 to 405 mL/min. The created retention functions had 3 characteristics: (a) no output until the minimal transit time (MinTT) followed by a linear increase in transit time; (b) ratio of MinTT to mean transit time (MTT) equal to 0.3 or 0.8; and (c) MTT between 3 and 60 min, increasing with 1-min steps. For each of the 1,160 renograms generated, output efficiency at time (t), OEt, was calculated at 20, 40, and 60 min. Mean and SD of OEt for all clearances were calculated for MTT values between 5 and 60 min, increasing with 5-min steps. Results: For the same retention function, different clearances resulted in different values of OEt. The degree of variability of OEt depended on several factors, including the value of t, the value of MTT, and the shape of the retention function, expressed as the MinTT-to-MTT ratio. For OE20, OE40, and OE60, the respective maximum SDs were 5.4%, 6.6%, and 7.1% for retention functions with a MinTT-to-MTT ratio equal to 0.3, and 6.2%, 8.4%, and 9.4% for retention functions with a MinTT-to-MTT ratio equal to 0.8. Conclusion: OE is influenced by renal function. Care should be taken in establishing the cutoff values for obstruction, nonobstruction, and the nondiagnostic zone, since a change in overall clearance can cause as much as a 20% variation in OE.

  • renography
  • output efficiency
  • renal function
  • simulation study

Transit evaluation is one of the main applications of radionuclide tests in nephro-urology, and the calculation of output efficiency (OE) may be the method of choice for this purpose (1–4). Unlike the deconvolution technique, OE may be applied to a nonstationary system, hence it can be calculated at any time during the renogram, after the furosemide test, or after the postmicturition image (5,6). Compared with the classical furosemide curve analysis, OE has the advantage of being independent of renal clearance, at least according to some researchers (6). However, Fleming et al. (7) showed that renal clearance did influence the value of OE. The aim of this study was to quantify the influence of renal function on OE and to analyze the factors that may modulate this effect.

MATERIALS AND METHODS

A series of renograms, R(i)n,m, were generated in a computer simulation model by convoluting real input functions, P(i)n, with artificial retention functions, H(i)m, in accordance with the equation: MathEq. 1 which, for discontinuous sampling methods can be written as: MathEq. 2 with i, the frame number, running from 1 to N, the total number of frames.

Time per frame and N were respectively set at 10 s and 720, resulting in a simulated acquisition of 120 min.

Plasma disappearance curves, P(i)n, of the renal tracer served as input function, which for discontinuous sampling methods can be expressed as (8): MathEq. 3

The values for percentage of injected dose, α1,n and α2,n, and the rate constants λ1,n and λ2,n were derived from plasma disappearance curves of 99mTc-MAG3 obtained in 10 patients chosen from our database. These plasma curves corresponded to renal clearances ranging from 33 to 405 mL/min, and increasing with approximately 40 mL/min intervals.

Two sets of retention functions were created. For the first set, the ratio of minimal transit time (MinTT) to mean transit time (MTT) was arbitrarily set at 0.3; for the second set, this ratio was arbitrarily set at 0.8. For each set, the MTT of the retention functions was set between 3 and 60 min, increasing with 1-min steps and resulting in 58 values for MTT. In this model we have disregarded the vascular phase; H(0) (the retention at i = 0) is therefore equal to 1. Subsequently, for each set and for every value of MTT, a retention function was created in a spreadsheet program (Microsoft Excel) reflecting a multinephron model with no output until MinTT, followed by a linear increase in transit time (Fig. 1) to the maximal transit time (MaxTT). Finally, each of the 116 retention functions, m, was convolved with each of the 10 plasma disappearance curves, n, and 1,160 renograms, R(i)n,m, were created.

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

Two retention functions at MTT = 30 min. Solid line represents MinTT = 9 min, MaxTT = 51 min; dotted line represents MinTT = 24 min, MaxTT = 36 min.

For every R(i)n,m, the OEn,m,t was calculated for t equals 20, 40, and 60 min according to the formula: MathEq. 4 which, expressed as a percentage, equals: MathEq. 5

The nominator of Equation 5, at t equals 20, 40, and 60 min, was calculated as the sum of frames 115 to 120, 235 to 240, and 355 to 360, respectively, of R(it)n,m, and the denominator was calculated as the sum of frames 1 to 120, 1 to 240, and 1 to 360, respectively, of P(it)n.

For each retention function, m, 10 values of OEn,m,t were calculated at a single time, t. Mean and SD of each value of OEn,m,t were calculated.

The relationship between mean and SD of OEt to MTT was expressed graphically; the former reflects the general tendency of OEt to MTT, while the latter reflects the variability of OEt induced by renal clearance.

RESULTS

As expected based on a previous study (9), the value of OEt varied depending on the value of t, the time of measurement. A nonlinear relationship was observed between OEt and MTT (Fig. 2).

FIGURE 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2.

Relationship of mean of OEt ± 1 SD to MTT for retention curves with (A) MinTT-to-MTT ratio = 0.3, and (B) MinTT-to-MTT = 0.8.

For each retention function m, the 10 plasma disappearance curves with different clearances resulted in renograms with different values for OEt, suggesting that renal function did influence OE. However, the degree of its effect was not constant. As shown in Figure 2, the SD of OEt was dependent on the values of t and MTT and the ratio of MinTT to MTT. This variation is more clearly shown in Figure 3, where the SD is presented against MTT. Moreover, in this figure, the variability of OEt when plotted against MTT follows the same shape whatever the value of t. It is low for very short MTT, increases with higher values of MTT until reaching a maximum, and decreases with increased values of MTT.

FIGURE 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 3.

Relationship of SD of OEt to MTT for retention curves with (A) MinTT-to-MTT ratio = 0.3, and (B) MinTT-to-MTT ratio = 0.8.

The location and degree of the maximum variability depend on the value of t. The maximum variability appeared at lower values of MTT for OE20 than for OE60, and the maximum variability of OE20 was lower than that of OE60.

At all values of t, the highest variability of OEt occurred when changes of OEt closely followed changes in MTT. This is seen by comparing Figure 2 and Figure 3. For example, Figure 3 shows that the highest variability for OE20 is observed at MTT = 10 min, whereas Figure 2 shows that a close relation between OE20 and MTT exists around the value of MTT = 10 min. The variability of OEt was also modulated by the shape of the retention function (when Fig. 3A is compared with Fig. 3B). For each OEt the shape of the SD curve follows the same general pattern, with an initial increase, a maximal value, and finally a decrease. However, the height and the spread of the SD curve varied as a function of OEt. The maximal variability was systematically higher in retention functions with a higher MinTT-to-MTT ratio. When compared with retention functions with a low MinTT-to-MTT ratio, the maximal variability occurs systematically at a higher value of MTT.

Quantitatively, the influence of renal function on OE was significant (Fig. 3). For OE20, OE40, and OE60, the maximum respective SDs observed were 5.4%, 6.6%, and 7.1% for a MinTT-to-MTT ratio equal to 0.3, and 6.2%, 8.4%, and 9.4% for a MinTT-to-MTT ratio equal to 0.8.

DISCUSSION

The concept of OE in the measurement of renal transit is particularly attractive. This parameter reflects the activity remaining in the kidney at a given moment compared with the total activity that has entered the kidney until that moment, and therefore indicates the efficacy of the output function. Like the deconvolution technique, OE is model-independent; unlike deconvolution, however, the stationary and linear conditions are not required for measuring OE. OE can therefore be measured at any time in the renogram, after the furosemide test, or after the postmicturition image.

According to the advocates of OE, one of its main advantages is its independence of renal clearance, rendering it superior to the classical furosemide-induced tracer washout-curve analysis. This claim has been contested by Fleming et al. (7). In a simulated study, these authors demonstrated the effect of renal clearance on OE. In their work, a rather unrealistic single-nephron model was used. One could therefore argue that their findings cannot be directly applied to a real-life situation (10).

In this study we have used a multinephron model with 2 different ratios of MinTT to MTT. Our results confirm the findings of Fleming et al. Renal clearance does influence OE and this influence is significant.

Why then the apparent disagreement between those claiming the independence of OE, and those who have observed a clear dependency on renal clearance? This may be due to confusion about which renal clearance is referred to. In a single-kidney model, OE is influenced only by the retention function, as H(i)m determines P(i)n entirely, and hence R(i)n,m (Eq. 2, Eq. 5). It therefore follows that, in a single-kidney model, OE can be expected to be independent of renal clearance. However, in a 2-kidney model, OE is influenced both by H(i)m and P(i)n independently, the latter being the plasma disappearance curve as the result of 2 functioning kidneys, and this in turn determines R(i)n,m, as shown in Equation 2. The model of OE takes into account the clearance of the single kidney on which OE is determined, and is therefore independent of the function of that kidney. The clearance studied by Fleming et al., as well as by this investigation, is the overall clearance.

Although OE has been shown to be less influenced by overall clearance than more traditional parameters such as Tmax or residual activity expressed as a percentage of maximal activity (11), this dependence still exists and is significant, since a change in overall clearance can produce as much as a 20% variation in OE.

CONCLUSION

According to the results of this study, renal function significantly influences OE. Taking into account the variation in OE induced by changes in overall clearance, the practical consequence of the influence of renal func-tion is that one should take care in establishing cutoff values for obstruction, nonobstruction, and a nondiagnostic zone.

Footnotes

  • Received Oct. 9, 2001; revision accepted Feb. 19, 2002.

    For correspondence contact: J.D. Kuyvenhoven, MD, Department of Nuclear Medicine, E 02.222, University Hospital Utrecht, P.O. Box 85500, 3508 GA Utrecht, The Netherlands.

    E-mail: J.D.C.S.Kuyvenhoven{at}azu.nl

REFERENCES

  1. ↵
    Whitfield HN, Britton KE, Nimmon CC, Hendry WF, Wallace DMA, Wickham JEA. Renal transit time measurements in the diagnosis of ureteric obstruction. Br J Urol. 1981;53:500–503.
    OpenUrlPubMed
  2. Piepsz A, Ham HR, Erbsmann F, et al. A co-operative study on the clinical value of dynamic renal scanning with deconvolution analysis. Br J Radiol. 1982;55:419–433.
    OpenUrlAbstract/FREE Full Text
  3. Russell CD, Japanwalla M, Khan S, Scott JW, Dubovsky EV. Techniques for measuring renal transit time. Eur J Nucl Med. 1995;22:1372–1378.
    OpenUrlCrossRefPubMed
  4. ↵
    Ham HR. Is renography suitable for deconvolution analysis? J Nucl Med. 1996;37:403–404.
    OpenUrlFREE Full Text
  5. ↵
    Spicer ST, Chi KK, Nankivell BJ, et al. Mercaptoacetyltriglycine diuretic renography and output efficiency in renal transplant patients. Eur J Nucl Med. 1999;26:152–154.
    OpenUrlPubMed
  6. ↵
    Chaiwatanarat T, Padhy AK, Bomanji JB, Nimmon CC, Somezoglu K, Britton KE. Validation of renal output efficiency as an objective quantitative parameter in the evaluation of upper urinary tract obstruction. J Nucl Med. 1993;34:845–848.
    OpenUrlAbstract/FREE Full Text
  7. ↵
    Fleming JS, Kemp PM. A Comparison of deconvolution and the Patlak-Rutland plot in renography analysis. J Nucl Med. 1999;40:1503–1507.
    OpenUrlAbstract/FREE Full Text
  8. ↵
    Sapirstein LA, Vidt DG, Mandel MJ, Hanusek G. Volumes of distribution and clearances of intravenously injected creatinine in the dog. Am J Physiol. 1955;181:330–336.
    OpenUrl
  9. ↵
    Kuyvenhoven JD, Ham H, Piepsz A. Optimal time window for calculation of two renal transit parameters: normalized residual activity and output efficiency. Eur J Nucl. Med. 2001;28:1256.
    OpenUrl
  10. ↵
    Fine DR, Lurie RE, Candy GP. An anatomical and physiological model of the renal parenchyma-model development and parametric identification. Physiol Meas. 1994;15:407–428.
    OpenUrlPubMed
  11. ↵
    Piepsz A, Tondeur M, Ham H. NORA: A simple and reliable parameter for estimating renal output with or without furosemide challenge. Nucl Med Commun. 2000;21:317–323.
    OpenUrlCrossRefPubMed
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 43 (6)
Journal of Nuclear Medicine
Vol. 43, Issue 6
June 1, 2002
  • Table of Contents
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Influence of Renal Function on Renal Output Efficiency
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Influence of Renal Function on Renal Output Efficiency
Jacob D. Kuyvenhoven, Hamphrey R. Ham, Amy Piepsz
Journal of Nuclear Medicine Jun 2002, 43 (6) 851-855;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Influence of Renal Function on Renal Output Efficiency
Jacob D. Kuyvenhoven, Hamphrey R. Ham, Amy Piepsz
Journal of Nuclear Medicine Jun 2002, 43 (6) 851-855;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Elimination of the Influence of Total Renal Function on Renal Output Efficiency and Normalized Residual Activity
  • Influence of Renal Function on Renal Output Efficiency
  • Google Scholar

More in this TOC Section

  • Tumor Uptake of Anti-CD20 Fabs Depends on Tumor Perfusion
  • How Sensitive Is the Upper Gastrointestinal Tract to 90Y Radioembolization? A Histologic and Dosimetric Analysis in a Porcine Model
  • 11C-Methionine PET of Myocardial Inflammation in a Rat Model of Experimental Autoimmune Myocarditis
Show more Basic Science Investigations