Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
OtherClinical Investigations

Analysis of Clinical Brain SPECT Data Based on Anatomic Standardization and Reference to Normal Data: An ROC-Based Comparison of Visual, Semiquantitative, and Voxel-Based Methods

Koenraad J. Van Laere, James Warwick, Jan Versijpt, Ingeborg Goethals, Kurt Audenaert, Ben Van Heerden and Rudi Dierckx
Journal of Nuclear Medicine April 2002, 43 (4) 458-469;
Koenraad J. Van Laere
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
James Warwick
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jan Versijpt
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ingeborg Goethals
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Kurt Audenaert
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ben Van Heerden
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Rudi Dierckx
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

The technique of anatomic standardization and comparison with normal templates is increasingly used in clinical brain SPECT practice and allows automated, operator-independent volume-of-interest (VOI) or voxel-based analysis of whole-brain data. In 2 distinct clinical populations with severe traumatic brain injury and cognitive impairment, this study compared 3 widely available approaches that use normal templates to evaluate SPECT brain perfusion deficits. Methods: In total, 74 subjects were studied. These included 14 patients with severe, traumatic brain injury (group 1; 10 males, 4 females; mean age ± SD, 27.6 ± 8.2 y) and 15 patients with cognitive impairment (group 2; 7 males, 8 females; mean age, 75.8 ± 8.6 y). These data were compared with those from, respectively, 25 and 20 age- and sex-adjusted healthy volunteers. All data were analyzed in 4 ways. Three semiquantitative statistical algorithms were used: statistical parametric mapping (SPM) using SPM99, brain registration and analysis of SPECT studies (BRASS) using a voxelwise region-growing technique, and a predefined VOI approach. These results were compared with visual analysis based on consensus reading by 3 experienced nuclear medicine physicians. Receiver operating characteristic (ROC) analysis was performed at various statistical cutoffs. Moreover, as a measure of regional agreement, relative regional agreement between methods was assessed. Results: In both study groups, BRASS voxel-based analysis was most accurate, as defined by the area under the ROC curve (0.97 for group 1 and 0.96 for group 2). VOI assessment was slightly more accurate than visual consensus analysis, whereas SPM showed, overall, a lower area under the ROC curve. SPM analysis was also significantly less sensitive at thresholds corresponding to low false-positive fractions. Regional analysis showed 83%–92% agreement between all methods. Conclusion: Under clinical conditions, classification of brain SPECT studies can greatly be aided by anatomic standardization techniques and reference to normal data. Under the investigated circumstances, SPM was found to have a lower sensitivity than VOI or voxelwise region-growing techniques, especially at low false-positive fractions.

  • SPECT
  • statistical parametric mapping
  • traumatic brain injury
  • cognitive impairment
  • anatomic standardization

Footnotes

  • Received Jun. 4, 2001; revision accepted Dec. 18, 2001.

    For correspondence or reprints contact: Koenraad J. Van Laere, MD, PhD, DrSc, Division of Nuclear Medicine, P7, Ghent University Hospital, De Pintelaan 185, 9000 Ghent, Belgium.

    E-mail: koen.vanlaere{at}rug.ac.be

View Full Text
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 43 (4)
Journal of Nuclear Medicine
Vol. 43, Issue 4
April 1, 2002
  • Table of Contents
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Analysis of Clinical Brain SPECT Data Based on Anatomic Standardization and Reference to Normal Data: An ROC-Based Comparison of Visual, Semiquantitative, and Voxel-Based Methods
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Analysis of Clinical Brain SPECT Data Based on Anatomic Standardization and Reference to Normal Data: An ROC-Based Comparison of Visual, Semiquantitative, and Voxel-Based Methods
Koenraad J. Van Laere, James Warwick, Jan Versijpt, Ingeborg Goethals, Kurt Audenaert, Ben Van Heerden, Rudi Dierckx
Journal of Nuclear Medicine Apr 2002, 43 (4) 458-469;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Analysis of Clinical Brain SPECT Data Based on Anatomic Standardization and Reference to Normal Data: An ROC-Based Comparison of Visual, Semiquantitative, and Voxel-Based Methods
Koenraad J. Van Laere, James Warwick, Jan Versijpt, Ingeborg Goethals, Kurt Audenaert, Ben Van Heerden, Rudi Dierckx
Journal of Nuclear Medicine Apr 2002, 43 (4) 458-469;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • Acknowledgments
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Construction and Evaluation of Multitracer Small-Animal PET Probabilistic Atlases for Voxel-Based Functional Mapping of the Rat Brain
  • Is Iterative Reconstruction an Alternative to Filtered Backprojection in Routine Processing of Dopamine Transporter SPECT Studies?
  • Clinical Testing of an Optimized Software Solution for an Automated, Observer-Independent Evaluation of Dopamine Transporter SPECT Studies
  • Neuroimaging tools to rate regional atrophy, subcortical cerebrovascular disease, and regional cerebral blood flow and metabolism: consensus paper of the EADC
  • Google Scholar

More in this TOC Section

  • Feasibility of Ultra-Low-Activity 18F-FDG PET/CT Imaging Using a Long–Axial-Field-of-View PET/CT System
  • Cardiac Presynaptic Sympathetic Nervous Function Evaluated by Cardiac PET in Patients with Chronotropic Incompetence Without Heart Failure
  • Validation and Evaluation of a Vendor-Provided Head Motion Correction Algorithm on the uMI Panorama PET/CT System
Show more Clinical Investigations

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire