Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportPhysics, Instrumentation & Data Sciences

Improved low count quantitative SPECT reconstruction with a trained deep learning based regularizer

Hongki Lim, Il Yong Chun, Jeffrey Fessler and Yuni Dewaraja
Journal of Nuclear Medicine May 2019, 60 (supplement 1) 42;
Hongki Lim
1University of Michigan Ann Arbor MI United States
2University of Michigan Ann Arbor MI United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Il Yong Chun
1University of Michigan Ann Arbor MI United States
2University of Michigan Ann Arbor MI United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jeffrey Fessler
1University of Michigan Ann Arbor MI United States
2University of Michigan Ann Arbor MI United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Yuni Dewaraja
1University of Michigan Ann Arbor MI United States
2University of Michigan Ann Arbor MI United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
Loading

Abstract

42

Aim: Improving low-count SPECT can lead to shorter scans and enable pre-therapy theranostic imaging for treatment planning in therapies with radionuclides such as Lu-177 (208 keV gamma: 10%) and Y-90 (low bremsstrahlung yield) that have low photon yields. In model-based image reconstruction, using more iterations of an unregularized method increases noise, so incorporating regularization into the image reconstruction is desirable to control noise in the low-count setting. Because conventional mathematically designed regularizers have a noise - resolution tradeoff, we designed a regularizer based on learned convolutional operators with the goal of improving noise and quantification at the same time.

Methods: Our proposed framework, BCD-Net, combines deep-learning with physics-based iterative reconstruction and consists of 2 core modules: 1) The image denoising module removes artifacts from an input image using convolutional filters and soft-thresholding. 2) The image reconstruction module performs regularized reconstruction penalizing the difference between unknown image and the clean image that is denoised by denoising module. To train BCD-Net, we used three Lu-177 patient studies with multiple acquisitions on a Symbia SPECT/CT. Patient images are acquired at 1-5 daysafter 7.4 GBq Lu-177 DOTATATE therapy for neuroendocrine tumors. To generate low-count realizations in training dataset, we resampled the post-therapy (high-count) measurement data with Poisson resampling rate of 0.5% to generate pre-therapy count-level (low-count) measurement (assuming that 37 MBq is used for pre-therapy imaging). To test BCD-Net, we used the following Lu-177 phantom and patient studies with acquisitions on a Symbia SPECT/CT: 1) measurement with hot spheres (‘lesions’) in the warm liver of a torso-phantom with a clinically realistic activity distribution, 2) measurement with six ‘hot’ spheres (2,4,8,16,30 and 113 mL) in a ‘warm’ background, and 3) one patient study not used for training. We performed additional short scans on patient to mimic a range of pre-therapy count-levels. We compared between standard unregularized EM algorithm, total variation (TV) conventional regularization, denoising U-Net, and our proposed BCD-Net. We evaluated each reconstruction method based on contrast-to-noise-ratio (CNR), activity-recovery (AR) with quantification using a point source-based calibration, and root mean squared error (RMSE in Bq/ml). We selected the regularization parameter (for TV and BCD-Net) and iteration number (for EM) to obtain the highest CNR.

Results: In phantom studies, visual comparison showed that the proposed BCD-Net reconstruction best matched the true image whereas unregularized EM generates noisy images and TV generates visually unnatural images. Image generated by denoising U-Net showed that the model is over-fitting. Quantitatively, in liver phantom study, BCD-Net significantly improved contrast between hot ‘lesions’ and warm ‘liver’ while reducing noise, thereby improving CNR. BCD-Net improved ‘lesion’ CNR by 21.8/32.9/96.0 (%), AR by 9.2/4.0/35.0 (%), and RMSE by 0.6/9.5/9.3 (%) compared to EM/TV/U-Net. In sphere phantom study, BCD-Net improved CNR by 119.3/176.7/77.5 (%) compared to EM/TV/U-Net. Bias - noise plots showed that BCD-Net decreases noise while improving AR unlike the conventional regularizer and EM. In patient studies, qualitative comparison showed that low-count BCD-Net reconstruction better matched the high-count images compared to other reconstructions.

Conclusions: In clinically realistic evaluations of low-count Lu-177 SPECT, the proposed BCD-Net reconstruction significantly improved contrast-to-noise-ratio and activity quantification compared with standard image reconstruction, conventional regularization method, and denoising U-Net. Further testing for different radionuclides and diverse imaging conditions are ongoing.

Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 60, Issue supplement 1
May 1, 2019
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Improved low count quantitative SPECT reconstruction with a trained deep learning based regularizer
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Improved low count quantitative SPECT reconstruction with a trained deep learning based regularizer
Hongki Lim, Il Yong Chun, Jeffrey Fessler, Yuni Dewaraja
Journal of Nuclear Medicine May 2019, 60 (supplement 1) 42;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Improved low count quantitative SPECT reconstruction with a trained deep learning based regularizer
Hongki Lim, Il Yong Chun, Jeffrey Fessler, Yuni Dewaraja
Journal of Nuclear Medicine May 2019, 60 (supplement 1) 42;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Physics, Instrumentation & Data Sciences

  • Exploration of Multi-objective Optimization with Genetic Algorithms for PET Image Reconstruction
  • AI-based methods for nuclear-medicine imaging: Need for objective task-specific evaluation
  • Ultra-Fast Reconstruction of Short List-Mode PET Data Frames for Real-Time Visualization and Processing
Show more Physics, Instrumentation & Data Sciences

Image Generation: ECT & CT

  • Exploration of Multi-objective Optimization with Genetic Algorithms for PET Image Reconstruction