Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportInstrumentation & Data Analysis

Feasibility of respiratory motion compensated reconstruction using 4D PET-derived deformation fields

Joyita Dutta, Georges El Fakhri, Xingfeng Shao, Auranuch Lorsakul, Ning Guo and Quanzheng Li
Journal of Nuclear Medicine May 2014, 55 (supplement 1) 2106;
Joyita Dutta
1Radiology, Massachusetts General Hospital, Boston, MA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Georges El Fakhri
1Radiology, Massachusetts General Hospital, Boston, MA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Xingfeng Shao
1Radiology, Massachusetts General Hospital, Boston, MA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Auranuch Lorsakul
1Radiology, Massachusetts General Hospital, Boston, MA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ning Guo
1Radiology, Massachusetts General Hospital, Boston, MA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Quanzheng Li
1Radiology, Massachusetts General Hospital, Boston, MA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
Loading

Abstract

2106

Objectives With the advent of simultaneous PET/MR technology, it is now possible to generate high-resolution 4D anatomical images from which accurate deformation fields and hence 4D attenuation maps can be derived and utilized for motion compensated image reconstruction (MCIR) for PET. In principle, it is feasible to estimate deformation fields from gated, non-attenuation corrected (NAC) PET images. However, so far no systematic study has been conducted to quantitatively evaluate PET-based motion estimation approaches and determine their feasibility. Our objective therefore is to compare two PET-based motion estimation techniques with MCIR based on accurate 4D attenuation maps.

Methods We performed realistic simulations using GATE to compare the following 3 methods on the XCAT torso phantom with 4 pulmonary lesions for 6 respiratory gates. Method 0: We performed MCIR with 4D attenuation maps based on the true deformation fields. As this is the best case scenario, we treated this result as our reference image for quantitative comparison. Method 1: We first derived deformation fields from gated NAC PET images and then performed MCIR with 4D attenuation maps based on the NAC PET derived deformation fields. Method 2: We first used the NAC PET derived deformation fields to warp the attenuation map to generate 4D gated and attenuation corrected (AC) PET images. We then used the AC PET images to re-compute the deformation fields. Finally, we performed MCIR with 4D attenuation maps based on the AC PET derived deformation fields.

Results The motion compensated image from Method 1 exhibited significant bias and artifacts, particularly near the heart and the diaphragm. Method 2 suppressed some of the artifacts. However, compared to Method 0, a large absolute bias ranging from 50 % to 400% was observed in the lesions.

Conclusions This study demonstrates that, although MCIR based on 4DPET-derived deformation fields is attractive due to its inherent simplicity, there are significant tradeoffs in terms of image bias and artifacts.

Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 55, Issue supplement 1
May 2014
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Feasibility of respiratory motion compensated reconstruction using 4D PET-derived deformation fields
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Feasibility of respiratory motion compensated reconstruction using 4D PET-derived deformation fields
Joyita Dutta, Georges El Fakhri, Xingfeng Shao, Auranuch Lorsakul, Ning Guo, Quanzheng Li
Journal of Nuclear Medicine May 2014, 55 (supplement 1) 2106;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Feasibility of respiratory motion compensated reconstruction using 4D PET-derived deformation fields
Joyita Dutta, Georges El Fakhri, Xingfeng Shao, Auranuch Lorsakul, Ning Guo, Quanzheng Li
Journal of Nuclear Medicine May 2014, 55 (supplement 1) 2106;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Instrumentation & Data Analysis

  • Assessment of SUV consistency in PET/CT with annulus 68Ge DQA phantom
  • Assessment of Tumor Burden in Lymphoma Patients with Deauville Score 4 Disease on Post Therapy FDG PET
  • Exploring the impact of feature selection methods and classification algorithms on the predictive performance of PET radiomic ML models in lung cancer
Show more Instrumentation & Data Analysis

MTA II: Image Generation Posters

  • Incorporating HYPR de-noising within iterative PET reconstruction (HYPR-OSEM)
  • Feasibility of Quantitative and Morphometric Bone Analysis Using a Next Generation Digital PET/CT Platform
  • Real-time Motion Correction Using High Resolution, High Frame Rate Video Monitoring and 64-bit Listmode Event Repositioning
Show more MTA II: Image Generation Posters