Abstract
PET/CT with 68Ga-DOTA-somatostatin analogs has been tested for therapy monitoring in patients with neuroendocrine tumors (NETs). However, standardized uptake values (SUV) in tumors do not correlate with the net influx rate (Ki), as a representation of the somatostatin receptor (SSTR) expression. In this study, tumor-to-blood-ratio (TBR) was evaluated as an alternative tool for semi-quantitative assessment of 68Ga-DOTATOC and 68Ga-DOTATATE tumor uptake and as a therapy monitoring tool for patients with NETs. Methods: Twenty-two NET patients underwent a 45-min dynamic PET/CT scan after injection of 68Ga-DOTATOC and/or 68Ga-DOTATATE. Ki was determined using the Patlak method and TBR was calculated for the 40-45 min time interval. Results: A linear relation was found between Ki and TBR, with a square of Pearson correlation (R2) of 0.98 and 0.93 for 68Ga-DOTATOC and 68Ga-DOTATATE, respectively. Conclusion: High correlation was found between Ki and TBR. Hence, TBR reflects SSTR density more accurately than SUV and is suggested as the preferred metrics for semi-quantitative assessment of 68Ga-DOTATOC and 68Ga-DOTATATE tumor uptake.
- Molecular Imaging
- Neuroendocrine
- PET/CT
- 68Ga-DOTATOC/68Ga-DOTATATE
- Net influx rate
- Neuroendocrine tumors
- SUV
- Tumor-to-blood ratio
- Copyright © 2019 by the Society of Nuclear Medicine and Molecular Imaging, Inc.