JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH RSS
 QUICK SEARCH:   [advanced]


     


First published online January 21, 2009
J Nucl Med 2009, doi:10.2967/jnumed.108.055756
© 2009 by Society of Nuclear Medicine
This Article
Right arrow Full Text (Publish Ahead of Print[PDF])
Right arrow All Versions of this Article:
jnumed.108.055756v1
50/2/309    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by O'Keefe, G. J.
Right arrow Articles by Rowe, C. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by O'Keefe, G. J.
Right arrow Articles by Rowe, C. C.


Radiation Dosimetry of {beta}-Amyloid Tracers 11C-PiB and 18F-BAY94-9172

Graeme J. O'Keefe 1*, Timothy H. Saunder 1, Steven Ng 1, Uwe Ackerman 1, Henri J. Tochon-Danguy 1, J. Gordon Chan 1, Sylvia Gong 1, Thomas Dyrks 2, Stefanie Lindemann 2, Gerhard Holl 2, Ludger Dinkelborg 2, Victor Villemagne 1, and Christopher C. Rowe 1

1 Centre for Positron Emission Tomography, Austin Hospital, Heidelberg, Victoria, Australia
2 Bayer Schering Pharma, Berlin, Germany

* To whom correspondence should be addressed. E-mail: graeme.okeefe{at}petnm.unimelb.edu.au.


   Abstract

{beta}-Amyloid (A{beta}) imaging has great potential to aid in the diagnosis of Alzheimer disease and the development of therapeutics. The radiation dosimetry of A{beta} radioligands may influence their application; therefore, we calculated and compared the effective doses (EDs) of 11C-PiB and a new 18F-labeled ligand, 18F-BAY94-9172. Methods: Attenuation-corrected whole-body scans were performed at 0, 15, 30, 45, and 60 min after injection of 350 ± 28 MBq (mean ± SD) of 11C-PiB in 6 subjects and at 0, 20, 60, 120, and 180 min after injection of 319 ± 27 MBq of 18F-BAY94-9172 in 3 subjects. Coregistered CT was used to define volumes of interest (VOIs) on the PET images. The source organs were the brain, lungs, liver, kidneys, spleen, and vertebrae. The VOIs for the contents of the gallbladder, urinary bladder, lower large intestine, upper large intestine, and small intestine were also defined. Total activity in each organ at each time point was calculated by use of reference organ volumes. The resultant time–activity curves were fitted with constrained exponential fits, and cumulated activities were determined. A dynamic bladder voiding model was used. The OLINDA/EXM program was used to calculate the whole-body EDs from the acquired data. Results: For 11C-PiB, the highest absorbed doses were in the gallbladder wall (44.80 ± 29.30 µGy/MBq), urinary bladder wall (26.30 ± 8.50 µGy/MBq), liver (19.88 ± 3.58 µGy/MBq), and kidneys (12.92 ± 3.37 µGy/MBq). The ED was 5.29 ± 0.66 µSv/MBq. For 18F-BAY94-9172, the highest doses were also in the gallbladder wall (132.40 ± 43.40 µGy/MBq), urinary bladder wall (24.77 ± 7.36 µGy/MBq), and liver (39.07 ± 8.31 µGy/MBq). The ED was 14.67 ± 1.39 µSv/MBq. Conclusion: The estimated organ doses for 11C-PiB were comparable to those reported in earlier research. With the doses used in published studies (300–700 MBq), the EDs would range from 1.6 to 3.7 mSv. The ED of 18F-BAY94-9172 was 30% lower than that of 18F-FDG and, at the published dose of 300 MBq, would yield an ED of 4.4 mSv. The dosimetry of both A{beta} radioligands is suitable for clinical and research applications.

Key Words: PET, radiation dosimetry, 11C-PiB, 18F-BAY94-9172




This article has been cited by other articles:


Home page
JNMHome page
M. Koole, D. M. Lewis, C. Buckley, N. Nelissen, M. Vandenbulcke, D. J. Brooks, R. Vandenberghe, and K. Van Laere
Whole-Body Biodistribution and Radiation Dosimetry of 18F-GE067: A Radioligand for In Vivo Brain Amyloid Imaging