|
|
|||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1 Division of Cardiology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts; Interventional Cardiology, Thoraxcenter, Erasmus MC, Rotterdam, The Netherlands
2 Division of Nuclear Medicine, Department of Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts
3 Division of Cardiology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts
* To whom correspondence should be addressed. E-mail: rlaham{at}bidmc.harvard.edu.
| Abstract |
|---|
PET/CT imaging with 18F-FDG has been used to detect inflammation in carotid and aortic plaque; its use in detecting coronary plaque has been limited by avid 18F-FDG uptake by the myocardium. We investigated whether 18F-FDG PET/CT could be used to image inflammation in coronary arteries as a potential noninvasive method to detect vulnerable plaque. Methods: We retrospectively studied 32 patients treated for malignancy who underwent 18F-FDG PET/CT and concomitant cardiac catheterization. As part of the recently described protocol, all patients were instructed to eat a low-carbohydrate, high-fat meal the night before and drink a vegetable oil drink the morning of the study. We reviewed the patients' baseline characteristics and their 18F-FDG PET/CT scans for adequacy of myocardial uptake suppression and correlated the presence of angiographically apparent plaque with 18F-FDG uptake in the major coronary arteries. Two independent observers assessed the angiographic images and 18F-FDG PET scans. Results: A total of 95% of patients had 2 or more coronary disease risk factors, and 25% had unstable symptoms; 30% of index catheterizations resulted in intervention. In 20 of 32 patients (63%), myocardial suppression was good (12) or adequate (8). Inadequate suppression was due to self-reported dietary nonadherence. Patients with good, adequate, and poor suppression had maximal myocardial standardized uptake values of 2.8 ± 0.7, 5.0 ± 1.3, and 17.0 ± 9.7, respectively. We identified 18F-FDG uptake in 15 patients in 1 or more coronary segments. A trend to significance in correlation between presence of angiographic disease and signal in the vessel was observed (P = 0.07; 80 vessels examined). A total of 7 patients with significant coronary artery disease had aortic 18F-FDG uptake. Conclusion: In this retrospective study, we demonstrated the potential use of 18F-FDG PET in imaging of inflammation in coronary arteries. The potential of 18F-FDG PET is also being investigated in a prospective study.
Key Words: vulnerable plaque, 18F-FDG PET/CT, imaging, coronary
This article has been cited by other articles:
![]() |
R. J. Gibbons, P. A. Araoz, and E. E. Williamson The year in cardiac imaging. J. Am. Coll. Cardiol., February 2, 2010; 55(5): 483 - 495. [Full Text] [PDF] |
||||
![]() |
A. Rominger, T. Saam, E. Vogl, C. Ubleis, C. la Fougere, S. Forster, A. Haug, P. Cumming, M. F. Reiser, K. Nikolaou, et al. In Vivo Imaging of Macrophage Activity in the Coronary Arteries Using 68Ga-DOTATATE PET/CT: Correlation with Coronary Calcium Burden and Risk Factors J. Nucl. Med., February 1, 2010; 51(2): 193 - 197. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. M. Matter, M. Stuber, and M. Nahrendorf Imaging of the unstable plaque: how far have we got? Eur. Heart J., November 1, 2009; 30(21): 2566 - 2574. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. J. Fox and H. W. Strauss One Step Closer to Imaging Vulnerable Plaque in the Coronary Arteries J. Nucl. Med., April 1, 2009; 50(4): 497 - 500. [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | RSS |
| JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY | THE JOURNAL OF NUCLEAR MEDICINE |