JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


First published online August 14, 2008
J Nucl Med 2008, doi:10.2967/jnumed.107.049833
© 2008 by Society of Nuclear Medicine
This Article
Right arrow Full Text (Publish Ahead of Print[PDF])
Right arrow All Versions of this Article:
jnumed.107.049833v1
49/9/1537    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Google Scholar
Right arrow Articles by Lindegren, S.
Right arrow Articles by Jensen, H.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lindegren, S.
Right arrow Articles by Jensen, H.


Direct Procedure for the Production of 211At-Labeled Antibodies with an {varepsilon}-Lysyl-3-(Trimethylstannyl)Benzamide Immunoconjugate

Sture Lindegren 1*, Sofia Frost 1, Tom Bäck 1, Elin Haglund 1, Jörgen Elgqvist 1, and Holger Jensen 2

1 Department of Radiation Physics, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
2 Cyclotron and PET Unit, KF-3982, Rigshospitalet, Copenhagen, Denmark

* To whom correspondence should be addressed. E-mail: sture.lindegren{at}radfys.gu.se.


   Abstract

211At-labeled tumor-specific antibodies have long been considered for the treatment of disseminated cancer. However, the limited availability of the nuclide and the poor efficacy of labeling procedures at clinical activity levels present major obstacles to their use. This study evaluated a procedure for the direct astatination of antibodies for the production of clinical activity levels. Methods: The monoclonal antibody trastuzumab was conjugated with the reagent N-succinimidyl-3-(trimethylstannyl)benzoate, and the immunoconjugate was labeled with astatine. Before astatination of the conjugated antibody, the nuclide was activated with N-iodosuccinimide. The labeling reaction was evaluated in terms of reaction time, volume of reaction solvent, immunoconjugate concentration, and applied activity. The quality of the astatinated antibodies was determined by in vitro analysis and biodistribution studies in nude mice. Results: The reaction proceeded almost instantaneously, and the results indicated a low dependence on immunoconjugate concentration and applied activity. Radiochemical labeling yields were in the range of 68%-81%, and a specific radioactivity of up to 1 GBq/mg could be achieved. Stability and radiochemical purity were equal to or better than those attained with a conventional 2-step procedure. Dissociation constants for directly astatinated, conventionally astatinated, and radioiodinated trastuzumab were 1.0 ± 0.06 (mean ± SD), 0.44 ± 0.06, and 0.29 ± 0.02 nM, respectively. The tissue distribution in non–tumor-bearing nude mice revealed only minor differences in organ uptake relative to that obtained with the conventional method. Conclusion: The direct astatination procedure enables the high-yield production of astatinated antibodies with radioactivity in the amounts required for clinical applications.

Key Words: astatination, 211At, radioimmunotherapy







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2008 by the Society of Nuclear Medicine.