JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


First published online March 14, 2008
J Nucl Med 2008, doi:10.2967/jnumed.107.047704
© 2008 by Society of Nuclear Medicine
This Article
Right arrow Full Text (Publish Ahead of Print[PDF])
Right arrow All Versions of this Article:
jnumed.107.047704v1
49/4/623    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Müller, C.
Right arrow Articles by de Jong, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Müller, C.
Right arrow Articles by de Jong, M.


Pemetrexed Improves Tumor Selectivity of 111In-DTPA-Folate in Mice with Folate Receptor–Positive Ovarian Cancer

Cristina Müller 1*, Roger Schibli 2, Eric P. Krenning 1, and Marion de Jong 1

1 Department of Nuclear Medicine, Erasmus Medical Center, Rotterdam, The Netherlands
2 Center for Radiopharmaceutical Science, ETH-PSI-USZ, Paul Scherrer Institute, Villigen-PSI, Switzerland; Department of Chemistry and Applied Biosciences, ETH Zurich, Zurich, Switzerland

* To whom correspondence should be addressed. E-mail: cristina.mueller{at}psi.ch.


   Abstract

Folate-based radiopharmaceuticals can be used as imaging agents and for potential radiotherapy of folate receptor (FR)–positive malignant tissue (e.g., ovarian carcinomas). However, substantial FR expression in the kidneys results in undesired renal retention of radioactivity. Recently, we found that the preinjection of an antifolate significantly improved tumor selectivity of organometallic 99mTc-radiofolates in mice. The aim of this study was to corroborate the effect of pemetrexed with the clinically tested 111In-DTPA-folate (DTPA is diethylenetriaminepentaacetic acid) in a human ovarian cancer xenografted mouse model. Methods: In vivo studies were performed in female athymic nude mice bearing subcutaneous FR-positive ovarian tumors (IGROV-1 and SKOV-3) or metastases (after intraperitoneal SKOV-3 cell inoculation). Biodistribution studies were performed 1, 4, and 24 h after administration of 111In-DTPA-folate (0.7 MBq/mouse, 0.35 µg) with or without preinjection of pemetrexed (PMX, 400 µg) 1 h before the radiofolate. Images were acquired with a high-resolution, high-sensitivity SPECT/CT camera, 4 and 24 h after injection of the radiotracer (30–50 MBq/mouse, 4.5–10 µg). Results: In biodistribution studies the tumor uptake of 111In-DTPA-folate (IGROV-1: 9.79 ± 3.21 %ID/g [percentage injected dose per gram]; SKOV-3: 7.57 ± 0.61 %ID/g, 4 h after injection) was high and retained over the time of investigation. However, considerable retention of radioactivity was found in kidneys (85–105 %ID/g, 4 h after injection), resulting in unfavorably low tumor-to-kidney ratios (~0.10). Preinjection of PMX resulted in a significant reduction of renal uptake (20%–30% of control values, P < 0.03) at all time points after injection of 111In-DTPA-folate, whereas the tumor uptake was retained. Thus, the tumor-to-kidney ratio was significantly increased to ~0.50. SPECT/CT images confirmed the superior tumor-to-background ratio in mice injected with PMX. These findings were particularly evident in mice with SKOV-3 metastases that could be visualized only when 111In-DTPA-folate was administered in combination with PMX. Conclusion: The application of PMX resulted in a significant reduction of undesired radioactivity accumulation in kidneys, whereas the tumor uptake remained unaffected. These observations suggest a general validity of the reducing effect of PMX on the uptake of radiofolates in kidneys. Our findings will lead the way toward the development of folate-based radiotherapy.

Key Words: folate receptor, 111In-DTPA-folate, pemetrexed, SPECT/CT, SKOV-3