JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


First published online March 14, 2008
J Nucl Med 2008, doi:10.2967/jnumed.107.046474
© 2008 by Society of Nuclear Medicine
This Article
Right arrow Full Text (Publish Ahead of Print[PDF])
Right arrow All Versions of this Article:
jnumed.107.046474v1
49/4/541    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kono, Y.
Right arrow Articles by Minowada, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kono, Y.
Right arrow Articles by Minowada, S.


Scintigraphic Detection of 125I Seeds After Permanent Brachytherapy for Prostate Cancer

Yuzuru Kono 1, Kazuo Kubota 1*, Takuya Mitsumoto 1, Akitomo Tanaka 1, Akihiko Ishibashi 1, Kazumi Kobayashi 2, Kimiteru Ito 1, Jun Itami 2, Mikio Kanemura 3, and Shigeru Minowada 3

1 Division of Nuclear Medicine, International Medical Center of Japan, Tokyo, Japan
2 Department of Radiology, International Medical Center of Japan, Tokyo, Japan
3 Department of Urology, International Medical Center of Japan, Tokyo, Japan

* To whom correspondence should be addressed. E-mail: kkubota{at}imcj.hosp.go.jp.


   Abstract

The purpose of this investigation was to monitor the localization and migration of 125I seeds after permanent brachytherapy for prostate cancer using a new scintigraphic technique that may overcome the drawbacks of conventional x-ray methods. Methods: 125I seeds emit {gamma}-rays with an average energy peak of 28 keV. We used a {gamma}-camera equipped with low-energy high-resolution collimators that were tuned to an energy level of 35 keV with a 70% window width. Sixteen patients with prostate cancer were examined after 125I seed insertion. The number of seeds remaining in the prostate was confirmed using pelvic CT for postoperative dose planning; however, seeds that had migrated outside the prostate could not be detected. Furthermore, the migrated seeds were not completely traceable using chest or abdominal radiography. Thus, we adopted a scintigraphic technique to perform this task. The evaluation of radiography and scintigraphy findings was masked, and the rates of migrated seed detection were statistically examined using the McNemar test. To localize the migrated seeds, we fused the scintigraphic images of the migrated seeds and the patients' contours. Results: Scintigraphy was successfully used to detect 20 migrated seeds of a total of 1,182 implanted seeds, whereas radiography was successfully used to detect 7. The sensitivity of the scintigraphy results was 20 of 20 (100%), whereas that of the radiography results was 7 of 20 (35%). Seed migration was detected in 11 of 16 patients (69%) using scintigraphy, whereas seed migration was detected in only 4 patients (25%) using radiography; this difference was statistically significant (P = 0.016). Conclusion: Scintigraphy is more effective for detecting seed migration and monitoring the localization of 125I seeds than radiography. The precise anatomic location of migrated seeds can be pinpointed using fusion images. Scintigraphy may become a standard procedure for monitoring seed migration during 125I brachytherapy in patients with prostate cancer.

Key Words: prostate cancer, brachytherapy, 125I seed, seed migration, fusion imaging