JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


First published online June 15, 2007
J Nucl Med 2007, doi:10.2967/jnumed.107.039941
© 2007 by Society of Nuclear Medicine
This Article
Right arrow Full Text (Publish Ahead of Print[PDF])
Right arrow All Versions of this Article:
jnumed.107.039941v1
48/7/1060    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Büther, F.
Right arrow Articles by Schäfers, K. P
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Büther, F.
Right arrow Articles by Schäfers, K. P


Effective Methods to Correct Contrast Agent-Induced Errors in PET Quantification in Cardiac PET/CT

Florian Büther 1*, * Lars Stegger 1, Mohammad Dawood 1, Felix Range 2, Michael Schäfers 1, Roman Fischbach 3, Thomas Wichter 2, Otmar Schober 1, and Klaus P Schäfers 1 *

1 Department of Nuclear Medicine, University of Münster, Münster, Germany
2 Department of Cardiology and Angiology, University of Münster, Münster, Germany
3 Department of Clinical Radiology, University of Münster, Münster, Germany

* To whom correspondence should be addressed. E-mail: butherf{at}uni-muenster.de.


   Abstract

In combined PET/CT studies, x-ray attenuation information from the CT scan is generally used for PET attenuation correction. Iodine-containing contrast agents may induce artifacts in the CT-generated attenuation map and lead to an erroneous radioactivity distribution on the corrected PET images. This study evaluated 2 methods of thresholding the CT data to correct these contrast agent-related artifacts. Methods: PET emission and attenuation data (acquired with and without a contrast agent) were simulated using a cardiac torso software phantom and were obtained from patients. Seven patients with known coronary artery disease underwent 2 electrocardiography-gated CT scans of the heart, the first without a contrast agent and the second with intravenous injection of an iodine-containing contrast agent. A 20-min PET scan (single bed position) covering the same axial range as the CT scans was then obtained 1 h after intravenous injection of 18F-FDG. For both the simulated data and the patient data, the unenhanced and contrast-enhanced attenuation datasets were used for attenuation correction of the PET data. Additionally, 2 threshold methods (one requiring user interaction) aimed at compensating for the effect of the contrast agent were applied to the contrast-enhanced attenuation data before PET attenuation correction. All PET images were compared by quantitative analysis. Results: Regional radioactivity values in the heart were overestimated when the contrast-enhanced data were used for attenuation correction. For patients, the mean decrease in the left ventricular wall was 23%. Use of either of the proposed compensation methods reduced the quantification error to less than 5%. The required time for postprocessing was minimal for the user-independent method. Conclusion: The use of contrast-enhanced CT images for attenuation correction in cardiac PET/CT significantly impairs PET quantification of tracer uptake. The proposed CT correction methods markedly reduced these artifacts; additionally, the user-independent method was time-efficient.

Key Words: PET/CT, attenuation correction, contrast agent, artifacts