JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


First published online December 12, 2007
J Nucl Med 2007, doi:10.2967/jnumed.107.039867
© 2007 by Society of Nuclear Medicine
This Article
Right arrow Full Text (Publish Ahead of Print[PDF])
Right arrow All Versions of this Article:
jnumed.107.039867v1
49/1/13    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Terasawa, T.
Right arrow Articles by Nagai, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Terasawa, T.
Right arrow Articles by Nagai, H.


18F-FDG PET for Posttherapy Assessment of Hodgkin's Disease and Aggressive Non-Hodgkin's Lymphoma: A Systematic Review

Teruhiko Terasawa 1*, Takashi Nihashi 2, Tomomitsu Hotta 1, and Hirokazu Nagai 1

1 Clinical Research Center for Blood Diseases, National Hospital Organization Nagoya Medical Center, Nagoya, Japan
2 Department of Radiology, National Center for Geriatrics and Gerontology, Obu City, Japan

* To whom correspondence should be addressed. E-mail: tterasawa{at}tufts-nemc.org.


   Abstract

Although studies have shown that 18F-FDG PET, when used to assess the response of malignant lymphoma after treatment, has a strong ability to predict relapse, its diagnostic accuracy in clinical practice remains unclear. The aim of this study was to systematically review the diagnostic accuracy of 18F-FDG PET in detecting residual disease at the completion of first-line therapy of Hodgkin's disease (HD) and aggressive non-Hodgkin's lymphoma (NHL). Methods: We searched relevant articles from 1966 to July 2006 using MEDLINE, EMBASE, SCOPUS, Biological Abstracts, bibliographies, review articles, and textbooks without language restriction. One assessor (for non–English-language studies) or 2 assessors (for English-language studies) independently reviewed each article to abstract relevant study characteristics and results. Relevant individual patient data or subgroup data were provided by the investigators if they were unavailable from the publications. We estimated summary receiver operating characteristic curves and confidence regions for summary sensitivity and specificity. Results: Nineteen studies consisting of 474 HD and 254 aggressive NHL patients were included. These studies had heterogeneity and suboptimal methodologic quality and reporting. Reported ranges for the sensitivity and specificity of 18F-FDG PET in predicting disease relapse were 0.50–1.00 and 0.67–1.00, respectively, for HD and 0.33–0.77 and 0.82–1.00, respectively, for NHL. These estimates were similar when conventional imaging tests showed a residual mass. For HD studies, the summary receiver operating characteristic curves were similar irrespective of whether a residual mass was detected by conventional tests. Factors explaining the variability of diagnostic estimates were not identified. Conclusion: Although currently available evidence is still limited, 18F-FDG PET seems to have good diagnostic accuracy for assessing residual HD at the completion of first-line treatment. Clinical data on this use of 18F-FDG PET for aggressive NHL are more limited. Prospective studies with a more rigorous research design, conduct, and reporting would more reliably reveal the clinical diagnostic accuracy of this imaging modality.

Key Words: 18F-FDG PET, lymphoma, response assessment, residual disease




This article has been cited by other articles:


Home page
Ann OncolHome page
J. Dupuis, E. Itti, A. Rahmouni, F. Hemery, C. Gisselbrecht, C. Lin, C. Copie-Bergman, K. Belhadj, T. El Gnaoui, I. Gaillard, et al.
Response assessment after an inductive CHOP or CHOP-like regimen with or without rituximab in 103 patients with diffuse large B-cell lymphoma: integrating 18fluorodeoxyglucose positron emission tomography to the International Workshop Criteria
Ann. Onc., December 11, 2008; (2008) mdn671v1.
[Abstract] [Full Text] [PDF]


Home page
ASH Education BookHome page
P. W.M. Johnson and A. J. Davies
Primary Mediastinal B-Cell Lymphoma
Hematology, January 1, 2008; 2008(1): 349 - 358.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2007 by the Society of Nuclear Medicine.