| Abstract |
|---|
Cardiac PET combined with CT is rapidly expanding despite artifactual defects and false-positive results due to misregistration of PET and CT attenuation correction data--the frequency, cause, and correction of which remain undetermined. Methods: Two hundred fifty-nine consecutive patients underwent diagnostic rest-dipyridamole myocardial perfusion PET/CT using 82Rb, a 16-slice PET/CT scanner, helical CT attenuation correction with breathing and also at end-expiratory breath-hold, and averaged cine CT data during breathing. Misregistration on superimposed PET/CT fusion images was objectively measured in millimeters and correlated with associated quantitative size and severity of PET defects. Misregistration artifacts were defined as PET defects with corresponding misregistration on helical CT-PET fusion images that resolved after correct coregistration using a repeat CT scan, cine CT averaged attenuation during normal breathing, or shifted cine CT data that coregistered with PET data. Results: Misregistration of standard helical CT PET images caused artifactual PET defects in 103 of 259 (40%) patients that were moderate to severe in 59 (23%) (P = 0.0000) and quantitatively normalized on cine or shifted cine CT PET (P = 0.0000). Quantitative misregistration was a powerful predictor of artifact size and severity (P = 0.0000), particularly for transaxial misregistration >6 mm occurring in anterior or lateral areas in 76%, in inferior areas in 16%, and at the apex in 8% of 103 artifactual defects. Conclusion: Misregistration of helical CT attenuation and PET emission images causes artifactual defects with false-positive results in 40% of patients that normalize on cine CT PET using averaged CT attenuation data during normal breathing comparable to normal breathing during PET emission scanning and shifting cine CT images to coregister visually with PET.
Key Words: PET, image registration, heart, attenuation, artifact
This article has been cited by other articles:
![]() |
P. J. Slomka, L. Le Meunier, S. W. Hayes, W. Acampa, M. Oba, G. G. Haemer, D. S. Berman, and G. Germano Comparison of Myocardial Perfusion 82Rb PET Performed with CT- and Transmission CT-Based Attenuation Correction J. Nucl. Med., December 1, 2008; 49(12): 1992 - 1998. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. K. Buck, S. Nekolla, S. Ziegler, A. Beer, B. J. Krause, K. Herrmann, K. Scheidhauer, H.-J. Wester, E. J. Rummeny, M. Schwaiger, et al. SPECT/CT J. Nucl. Med., August 1, 2008; 49(8): 1305 - 1319. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. W. Townsend Dual-Modality Imaging: Combining Anatomy and Function J. Nucl. Med., June 1, 2008; 49(6): 938 - 955. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. L. Gould, T. Pan, C. Loghin, N. P. Johnson, and S. Sdringola Reducing Radiation Dose in Rest-Stress Cardiac PET/CT by Single Poststress Cine CT for Attenuation Correction: Quantitative Validation J. Nucl. Med., May 1, 2008; 49(5): 738 - 745. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. L. Gould Not All Randomized Trials Are Equal J. Am. Coll. Cardiol., November 13, 2007; 50(20): 2013 - 2015. [Full Text] [PDF] |
||||
![]() |
K. L. Gould and T. Pan Reply: Attenuation Correction for Stress and Rest PET 82Rb Myocardial Perfusion Images J. Nucl. Med., November 1, 2007; 48(11): 1913 - 1914. [Full Text] [PDF] |
||||
![]() |
R. L. Eisner and R. E. Patterson Attenuation Correction for Stress and Rest PET 82Rb Myocardial Perfusion Images J. Nucl. Med., November 1, 2007; 48(11): 1912 - 1913. [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH |
| JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY | THE JOURNAL OF NUCLEAR MEDICINE |