JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Related articles in JNM
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schuster, D. M.
Right arrow Articles by Goodman, M. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schuster, D. M.
Right arrow Articles by Goodman, M. M.
Journal of Nuclear Medicine Vol. 48 No. 1 56-63
© 2007 by Society of Nuclear Medicine


Basic Science Investigation

Initial Experience with the Radiotracer Anti-1-Amino-3-18F-Fluorocyclobutane-1-Carboxylic Acid with PET/CT in Prostate Carcinoma

David M. Schuster1, John R. Votaw1, Peter T. Nieh2, Weiping Yu1, Jonathon A. Nye1, Viraj Master2, F. DuBois Bowman3, Muta M. Issa2 and Mark M. Goodman1

1 Division of Nuclear Medicine, Department of Radiology, Emory University, Atlanta, Georgia; 2 Department of Urology, Emory University, Atlanta, Georgia; and 3 Department of Biostatistics, Emory University, Atlanta, Georgia

Correspondence: For correspondence or reprints contact: David M. Schuster, MD, Department of Radiology, Emory University Hospital, Room E145, 1364 Clifton Rd., Atlanta, GA 30322. E-mail: david.schuster{at}emoryhealthcare.org

Conventional imaging techniques have serious limitations in the detection, staging, and restaging of prostate carcinoma. Anti-1-amino-3-18F-fluorocyclobutane-1-carboxylic acid (anti-18F-FACBC)is a synthetic L-leucine analog that has excellent in vitro uptake within the DU-145 prostate carcinoma cell line and orthotopically implanted prostate tumor in nude rats. There is little renal excretion compared with 18F-FDG. The present study examines anti-18F-FACBC uptake in patients with newly diagnosed and recurrent prostate carcinoma. Methods: Fifteen patients with a recent diagnosis of prostate carcinoma (n = 9) or suspected recurrence (n = 6) underwent 65-min dynamic PET/CT of the pelvis after intravenous injection of 300–410 MBq anti-18F-FACBC followed by static body images. Each study was evaluated qualitatively and quantitatively. Maximum standardized uptake values were recorded in the prostate or prostate bed, and within lymph nodes at 4.5 min (early) and 20 min (delayed), and correlated with clinical, imaging and pathologic follow-up. Time–activity curves were also generated for benign and malignant tissue. Results: In the 8 patients with newly diagnosed prostate carcinoma who underwent dynamic scanning, visual analysis correctly identified the presence or absence of focal neoplastic involvement in 40 of 48 prostate sextants. Pelvic nodal status correlated with anti-18F-FACBC findings in 7 of 9 patients and was indeterminate in 2 of 9. In all 4 patients in whom there was proven recurrence, visual analysis was successful in identifying disease (1 prostate bed, 3 extraprostatic). In 3 of these patients, 111In-capromab-pendetide had no significant uptake at nodal and skeletal foci. Malignant lymph node uptake in both the staging and restaging patients was significantly higher than benign nodal uptake. Though uptake faded with time, in all 6 patients with either lymph node metastases or recurrent prostate bed carcinoma, there was intense persistent uptake at 65 min. Conclusion: Anti-18F-FACBC is a promising radiotracer for imaging prostate carcinoma. Radiotracer uptake was demonstrated in primary and metastatic disease. Future research should investigate the mechanism of radiotracer uptake in normal and pathologic tissue and develop a clinical imaging strategy for initial staging and restaging.

Key Words: anti-18F-FACBC • prostate • neoplasia • PET

COPYRIGHT © 2007 by the Society of Nuclear Medicine, Inc.


Related articles in JNM:

This Month in JNM

JNM 2007 48: 11a-12a. [Full Text]  



This article has been cited by other articles:


Home page
Clin. Cancer Res.Home page
J. V. Leyton, T. Olafsen, E. J. Lepin, S. Hahm, K. B. Bauer, R. E. Reiter, and A. M. Wu
Humanized Radioiodinated Minibody For Imaging of Prostate Stem Cell Antigen-Expressing Tumors
Clin. Cancer Res., November 15, 2008; 14(22): 7488 - 7496.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
C. Plathow and W. A. Weber
Tumor Cell Metabolism Imaging
J. Nucl. Med., June 1, 2008; 49(Suppl_2): 43S - 63S.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
V. Kundra, P. M. Silverman, S. F. Matin, and H. Choi
Imaging in Oncology from The University of Texas M. D. Anderson Cancer Center: Diagnosis, Staging, and Surveillance of Prostate Cancer
Am. J. Roentgenol., October 1, 2007; 189(4): 830 - 844.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
T. R. DeGrado, S. A. Kwee, M. N. Coel, and R. E. Coleman
The Impact of Urinary Excretion of 18F-Labeled Choline Analogs
J. Nucl. Med., July 1, 2007; 48(7): 1225 - 1225.
[Full Text] [PDF]


Home page
JNMHome page
J. A. Nye, D. M. Schuster, W. Yu, V. M. Camp, M. M. Goodman, and J. R. Votaw
Biodistribution and Radiation Dosimetry of the Synthetic Nonmetabolized Amino Acid Analogue Anti-18F-FACBC in Humans
J. Nucl. Med., June 1, 2007; 48(6): 1017 - 1020.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
S. Oka, R. Hattori, F. Kurosaki, M. Toyama, L. A. Williams, W. Yu, J. R. Votaw, Y. Yoshida, M. M. Goodman, and O. Ito
A Preliminary Study of Anti-1-Amino-3-18F-Fluorocyclobutyl-1-Carboxylic Acid for the Detection of Prostate Cancer
J. Nucl. Med., January 1, 2007; 48(1): 46 - 55.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2007 by the Society of Nuclear Medicine.