JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schepis, T.
Right arrow Articles by Kaufmann, P. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schepis, T.
Right arrow Articles by Kaufmann, P. A.
Journal of Nuclear Medicine Vol. 47 No. 8 1288-1294
© 2006 by Society of Nuclear Medicine


Clinical Investigation

Comparison of 64-Slice CT with Gated SPECT for Evaluation of Left Ventricular Function

Tiziano Schepis1, Oliver Gaemperli1, Pascal Koepfli1, Ines Valenta1, Klaus Strobel1, Andrea Brunner1, Sebastian Leschka2, Lotus Desbiolles2, Lars Husmann2, Hatem Alkadhi2 and Philipp A. Kaufmann1,3

1 Clinic of Nuclear Medicine, Nuclear Cardiology, University Hospital Zurich, Zurich, Switzerland; 2 Institute of Diagnostic Radiology, University Hospital Zurich, Zurich, Switzerland; and 3 Center for Integrative Human Physiology, University Zurich, Zurich, Switzerland

Correspondence: For correspondence or reprints contact: Philipp A. Kaufmann, MD, Nuclear Cardiology, Cardiovascular Center, University Hospital Zurich, Raemistrasse 100, CH-8091 Zurich, Switzerland. E-mail: pak{at}usz.ch

Precise and reliable assessment of left ventricular (LV) function and dimensions is prognostically important in cardiac patients. As the integration of SPECT and multislice CT into hybrid scanners will promote the combined use of both techniques in the same patient, a comparison of the 2 methods is pertinent. We aimed at comparing LV dimensions, muscle mass, and function obtained by electrocardiographically gated 64-slice CT versus gated-SPECT. Methods: Sixty patients (mean age, 64 ± 8 y) referred for evaluation of coronary artery disease underwent 99mTc-tetrofosmin gated SPECT and 64-slice CT within 4 ± 2 d. LV ejection fraction (LVEF), end-systolic volume (ESV), and end-diastolic volume (EDV) from CT were compared with SPECT. Additionally, LV muscle mass and quantitative regional wall motion were assessed in 20 patients with both methods. Results: CT was in good agreement with SPECT for quantification of LVEF (r = 0.825), EDV (r = 0.898), and ESV (r = 0.956; all P < 0.0001). LVEF was 59% ± 13% measured by SPECT and slightly higher but not significantly different by CT (60% ± 12%; mean difference compared with SPECT, 1.1% ± 1.7%; P = not significant). A systematic overestimation using CT for EDV (147 ± 60 mL vs. 113 ± 52 mL; mean difference, 33.5 ± 23.1 mL) and ESV (63 ± 55 mL vs. 53 ± 49 mL; mean difference, 9.3 ± 15.9 mL; P < 0.0001) was found compared with SPECT. A good correlation for muscle mass was found between the 2 methods (r = 0.868; P < 0.005). However, muscle mass calculated by SPECT was significantly lower compared with CT (127 ± 24 g vs. 148 ± 37 g; mean difference, 23.0 ± 12.2 g; P < 0.001). The correlation for regional wall motion between the 2 methods was moderate (r = 0.648; P < 0.0001). Conclusion: LVEF and LV functional parameters as determined by 64-slice CT agree over a wide range of clinically relevant values with gated SPECT. However, interchangeable use of the 2 techniques should be avoided for LV volumes, muscle mass, and regional wall motion because of variances inherent to the different techniques.

Key Words: left ventricular function • gated SPECT • multislice CT




This article has been cited by other articles:


Home page
Eur Heart JHome page
B. A. Herzog, L. Husmann, N. Burkhard, O. Gaemperli, I. Valenta, F. Tatsugami, C. A. Wyss, U. Landmesser, and P. A. Kaufmann
Accuracy of low-dose computed tomography coronary angiography using prospective electrocardiogram-triggering: first clinical experience
Eur. Heart J., December 2, 2008; 29(24): 3037 - 3042.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
A. Chander, M. Brenner, R. Lautamaki, C. Voicu, J. Merrill, and F. M. Bengel
Comparison of Measures of Left Ventricular Function from Electrocardiographically Gated 82Rb PET with Contrast-Enhanced CT Ventriculography: A Hybrid PET/CT Analysis
J. Nucl. Med., October 1, 2008; 49(10): 1643 - 1650.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
K. U. Juergens, H. Seifarth, F. Range, S. Wienbeck, M. Wenker, W. Heindel, and R. Fischbach
Automated Threshold-Based 3D Segmentation Versus Short-Axis Planimetry for Assessment of Global Left Ventricular Function with Dual-Source MDCT
Am. J. Roentgenol., February 1, 2008; 190(2): 308 - 314.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
L. Husmann, I. Valenta, O. Gaemperli, O. Adda, V. Treyer, C. A. Wyss, P. Veit-Haibach, F. Tatsugami, G. K. von Schulthess, and P. A. Kaufmann
Feasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating
Eur. Heart J., January 2, 2008; 29(2): 191 - 197.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
H. Brodoefel, U. Kramer, A. Reimann, C. Burgstahler, S. Schroeder, A. Kopp, and M. Heuschmid
Dual-Source CT with Improved Temporal Resolution in Assessment of Left Ventricular Function: A Pilot Study
Am. J. Roentgenol., November 1, 2007; 189(5): 1064 - 1070.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
R. J. Gibbons, P. A. Araoz, and E. E. Williamson
The Year in Cardiac Imaging
J. Am. Coll. Cardiol., September 4, 2007; 50(10): 988 - 1003.
[Full Text] [PDF]


Home page
JNMHome page
N. Dudley and C. Kalirai
Comparison of 64-Slice CT with Gated SPECT for Evaluation of Left Ventricular Function
J. Nucl. Med., June 1, 2007; 48(6): 1038 - 1038.
[Full Text] [PDF]


Home page
JNMHome page
P. A. Kaufmann and O. Gaemperli
Reply: Comparison of 64-Slice CT with Gated SPECT for Evaluation of Left Ventricular Function
J. Nucl. Med., June 1, 2007; 48(6): 1038a - 1038a.
[Full Text] [PDF]


Home page
JNMHome page
O. Gaemperli, T. Schepis, I. Valenta, L. Husmann, H. Scheffel, V. Duerst, F. R. Eberli, T. F. Luscher, H. Alkadhi, and P. A. Kaufmann
Cardiac Image Fusion from Stand-Alone SPECT and CT: Clinical Experience
J. Nucl. Med., May 1, 2007; 48(5): 696 - 703.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2006 by the Society of Nuclear Medicine.