JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Beekman, F. J.
Right arrow Articles by Smidt, M. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Beekman, F. J.
Right arrow Articles by Smidt, M. P.
Journal of Nuclear Medicine Vol. 46 No. 7 1194-1200
© 2005 by Society of Nuclear Medicine


Basic Science Investigations

U-SPECT-I: A Novel System for Submillimeter-Resolution Tomography with Radiolabeled Molecules in Mice

Freek J. Beekman, PhD1,2, Frans van der Have, MSc1,2, Brendan Vastenhouw, MSc1,2, Annemarie J.A. van der Linden, BSc2, Peter P. van Rijk, MD, PhD1, J. Peter H. Burbach, PhD2 and Marten P. Smidt, PhD2

1 Department of Nuclear Medicine, Image Sciences Institute, University Medical Center Utrecht, Utrecht, The Netherlands
2 Department of Pharmacology and Anatomy, University Medical Center Utrecht, Utrecht, The Netherlands

A major advance in biomedical science and diagnosis was accomplished with the development of in vivo techniques to image radiolabeled molecules, but limited spatial resolution has slowed down applications to small experimental animals. Here, we present a SPECT system (U-SPECT-I) dedicated to radionuclide imaging of murine organs at a submillimeter resolution. Methods: The high performance of U-SPECT-I is based on a static triangular detector setup, with a cylindric imaging cavity in the center and 75 gold micropinhole apertures in the cavity wall. The pinholes are focused on a small volume of interest such as the mouse heart or spine to maximize the detection yield of {gamma}-photons. Three-dimensional molecular distributions are iteratively estimated using the detector data and a statistical reconstruction algorithm that takes into account system blurring and data noise to increase resolution and reduce image noise. Results: With 0.6-mm-diameter pinholes, the maximum fraction of detected photons emitted by a point source (peak sensitivity) is 0.22% for a 15%-wide energy window and remains higher than 0.12% in the central 12 mm of the central plane. In a resolution phantom, radioactively filled capillaries as small as 0.5 mm and separated by 0.5 mm can be distinguished clearly in reconstructions. Projection data needed for the reconstruction of cross sections of molecular distributions in mouse organs can readily be obtained without the need for any mechanical movements. Images of a mouse spine show 99mTc-hydroxymethylene diphosphonate uptake down to the level of tiny parts of vertebral processes. These are separated clearly from the vertebral and intervertebral foramina. Using another tracer, one can monitor myocardial perfusion in the left and right ventricular walls, even in structures as small as the papillary muscles. Conclusion: U-SPECT-I allows discrimination between molecular concentrations in adjacent volumes of as small as about 0.1 µL, which is significantly smaller than can be imaged by any existing SPECT or PET system. Our initial in vivo images of the mouse heart and spine show that U-SPECT-I can be used for novel applications in the study of dynamic biologic systems with a clear projection to clinical applications. The combination of high resolution and detection efficiency of U-SPECT-I opens up new possibilities for the suborgan-level study of radiotracers in mouse models.

Key Words: molecular imaging • pinhole • SPECT • mouse • reconstruction




This article has been cited by other articles:


Home page
JNMHome page
B. L. Franc, P. D. Acton, C. Mari, and B. H. Hasegawa
Small-Animal SPECT and SPECT/CT: Important Tools for Preclinical Investigation
J. Nucl. Med., October 1, 2008; 49(10): 1651 - 1663.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
Y.-C. Tai, H. Wu, D. Pal, and J. A. O'Sullivan
Virtual-Pinhole PET
J. Nucl. Med., March 1, 2008; 49(3): 471 - 479.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
C. Goetz, E. Breton, P. Choquet, V. Israel-Jost, and A. Constantinesco
SPECT Low-Field MRI System for Small-Animal Imaging
J. Nucl. Med., January 1, 2008; 49(1): 88 - 93.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
H. Wu, D. Pal, J. A. O'Sullivan, and Y.-C. Tai
A Feasibility Study of a Prototype PET Insert Device to Convert a General-Purpose Animal PET Scanner to Higher Resolution
J. Nucl. Med., January 1, 2008; 49(1): 79 - 87.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
B. B. Chin, S. D. Metzler, A. Lemaire, A. Curcio, S. Vemulapalli, K. L. Greer, N. A. Petry, T. G. Turkington, R. E. Coleman, H. Rockman, et al.
Left Ventricular Functional Assessment in Mice: Feasibility of High Spatial and Temporal Resolution ECG-gated Blood Pool SPECT
Radiology, November 1, 2007; 245(2): 440 - 448.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
M. T. Madsen
Recent Advances in SPECT Imaging
J. Nucl. Med., April 1, 2007; 48(4): 661 - 673.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
B. Vastenhouw and F. Beekman
Submillimeter Total-Body Murine Imaging with U-SPECT-I
J. Nucl. Med., March 1, 2007; 48(3): 487 - 493.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
J. Petersson, A. Sanchez-Crespo, S. A. Larsson, and M. Mure
Physiological imaging of the lung: single-photon-emission computed tomography (SPECT)
J Appl Physiol, January 1, 2007; 102(1): 468 - 476.
[Abstract] [Full Text] [PDF]


Home page
Proc Am Thorac SocHome page
A. F. Chatziioannou
Instrumentation for Molecular Imaging in Preclinical Research: Micro-PET and Micro-SPECT
Proceedings of the ATS, December 1, 2005; 2(6): 533 - 536.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2005 by the Society of Nuclear Medicine.