Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Research ArticleClinical Investigation
Open Access

Impact of the Reference Multiple-Time-Point Dosimetry Protocol on the Validity of Single-Time-Point Dosimetry for [177Lu]Lu-PSMA-I&T Therapy

Sandra Resch, Sibylle I. Ziegler, Gabriel Sheikh, Lena M. Unterrainer, Mathias J. Zacherl, Peter Bartenstein, Guido Böning, Julia Brosch-Lenz and Astrid Delker
Journal of Nuclear Medicine August 2024, 65 (8) 1272-1278; DOI: https://doi.org/10.2967/jnumed.123.266871
Sandra Resch
1Department of Nuclear Medicine, LMU University Hospital, LMU, Munich, Germany;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Sibylle I. Ziegler
1Department of Nuclear Medicine, LMU University Hospital, LMU, Munich, Germany;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Gabriel Sheikh
1Department of Nuclear Medicine, LMU University Hospital, LMU, Munich, Germany;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Lena M. Unterrainer
1Department of Nuclear Medicine, LMU University Hospital, LMU, Munich, Germany;
2Ahmanson Translational Theranostics Division, Department of Molecular and Medical Pharmacology, UCLA, Los Angeles, California; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Mathias J. Zacherl
1Department of Nuclear Medicine, LMU University Hospital, LMU, Munich, Germany;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Peter Bartenstein
1Department of Nuclear Medicine, LMU University Hospital, LMU, Munich, Germany;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Guido Böning
1Department of Nuclear Medicine, LMU University Hospital, LMU, Munich, Germany;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Julia Brosch-Lenz
3Department of Nuclear Medicine, Technical University of Munich, Munich, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Astrid Delker
1Department of Nuclear Medicine, LMU University Hospital, LMU, Munich, Germany;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF
Loading

Visual Abstract

Figure
  • Download figure
  • Open in new tab
  • Download powerpoint

Abstract

Internal dosimetry supports safe and effective patient management during radionuclide therapy. Yet, it is associated with high clinical workload, costs, and patient burden, as patient scans at multiple time points (MTPs) must be acquired. Dosimetry based on imaging at a single time point (STP) has continuously gained popularity. However, MTP protocols, used as a reference to judge the validity of STP dosimetry, differ depending on local requirements and deviate from the unknown patient-specific ground truth pharmacokinetics. The aim of this study was to compare the error and optimum time point for different STP approaches using different reference MTP protocols. Methods: Whole-body SPECT/CT scans of 7 patients (7.4–8.9 GBq of [177Lu]Lu-PSMA-I&T) were scheduled at 24, 48, 72, and 168 h after injection. Sixty lesions, 14 kidneys, and 10 submandibular glands were delineated in the SPECT/CT data. Two curve models, that is, a mono- and a biexponential model, were fitted to the MTP data, in accordance with goodness-of-fit analysis (coefficients of variation, sum of squared errors). Three population-based STP approaches were compared: one method published by Hänscheid et al., one by Jackson et al., and one using population-based effective half-lives in the mono- or biexponential curve models. Percentage differences between STP and MTP dosimetry were evaluated. Results: Goodness-of-fit parameters show that a monoexponential function and a biexponential function with shared population-based parameters and physical tail are reasonable reference models. When comparing both reference models, we observed maximum differences of −44%, −19%, and −28% in the estimated absorbed doses for lesions, kidneys, and salivary glands, respectively. STP dosimetry with an average deviation of less than 10% from MTP dosimetry may be feasible; however, this deviation and the optimum imaging time point showed a dependence on the chosen reference protocol. Conclusion: STP dosimetry for [177Lu]Lu-PSMA therapy is promising to boost the integration of dosimetry into clinical routine. According to our patient cohort, 48 h after injection may be regarded as a compromise for STP dosimetry for lesions and at-risk organs. The results from this analysis show that a common gold standard for dosimetry is desirable to allow for reliable and comparable STP dosimetry.

  • PSMA
  • 177Lu
  • dosimetry
  • single time point

Targeting of the prostate-specific membrane antigen (PSMA) with [177Lu]Lu-PSMA therapy evolved as a promising strategy for the treatment of metastasized castration-resistant prostate cancer, which is one of the main worldwide causes of death in men (1). The VISION trial led to the approval of [177Lu]Lu-vipivotide tetraxetan (Pluvicto; Novartis) by the U.S. Food and Drug Administration in March 2022 and by the European Medicines Agency in December 2022 (2). Patient-specific internal dosimetry supports safe and efficient patient management during radionuclide therapy by monitoring the absorbed radiation dose to both healthy and malignant tissues (3,4). However, internal dosimetry requires quantitative images, preferably SPECT or PET, at multiple time points (MTPs) at least over the initial days after injection (5–7). The associated high number of examinations poses a high workload and additional costs to the clinics in cases of unclear reimbursement. These factors have so far limited the routine implementation of clinical dosimetry, although it is more and more legally requested (8,9). The rising number of therapies as expected after the U.S. Food and Drug Administration and European Medicines Agency approval of [177Lu]Lu-vipivotide tetraxetan will probably further complicate the integration of routine dosimetry into the clinical workflow. On the other hand, only routine dosimetry with reasonable accuracy can provide the empiric knowledge that is necessary to tailor PSMA therapy more to the individual patient characteristics, as for example, with respect to treatment activity per cycle or number of cycles.

To handle the workload associated with increasing routine use of dosimetry, dosimetry based on fewer image acquisitions and even single-time-point (STP) dosimetry methods are being intensively investigated for 177Lu-based treatments (10–25). Depending on the selected imaging time point, these protocols lay within an acceptable agreement of around 10% compared with a selected ground truth protocol that is based on serial quantitative imaging. To derive the time-integrated activity (TIA) for each tissue of interest, most of the proposed STP methods measure the uptake per tissue based on a single quantitative image and combine this single uptake measurement with some prior knowledge about the tissue-specific effective half-life. The latter could be a population-based effective half-life or the patient-specific effective half-life of a former therapy cycle. Besides the exact STP method used for the calculation of the TIA itself, so far published methods differ regarding the considered reference model (Table 1). The reference model for MTP dosimetry is defined by the number and timing of the image acquisition itself and the mathematic fit model that is applied to the data points. These reference protocols are highly variable between institutions, as internal dosimetry still lacks standardization, and as site-specific protocols must be tailored to the local situation. Because the reference model is usually already limited by clinical feasibility, it cannot be considered a real ground truth but already represents an approximation with some protocol-dependent error. Thus, findings on STP dosimetry such as optimum time point and percentage deviation compared with MTP dosimetry cannot necessarily be transferred from one considered MTP reference protocol to another. The aim of this study was to investigate how the choice of reference model affects selection of the optimum method for STP dosimetry in the scope of [177Lu]Lu-PSMA-I&T therapy.

View this table:
  • View inline
  • View popup
TABLE 1.

Overview of STP Dosimetry for [177Lu]Lu-PSMA Therapy

MATERIALS AND METHODS

Patients

This study included 7 patients diagnosed with metastasized castration-resistant prostate cancer in their first cycle of [177Lu]Lu-PSMA-I&T therapy (Table 2). All patients gave written consent to undergo radiopharmaceutical therapy. The institutional review board approved this retrospective study, and the requirement to obtain informed consent was waived (reference 22-0552).

View this table:
  • View inline
  • View popup
TABLE 2.

Patient Information

Imaging

SPECT/CT measurements were scheduled 24, 48, 72, and 168 h after injection on a dual-head Symbia Intevo T16 SPECT/CT (Siemens Healthineers) using a standard 177Lu protocol (26) (Supplemental Fig. 1; supplemental materials are available at http://jnm.snmjournals.org).

Dosimetry

Sixty lesions, 14 kidneys, and 10 submandibular glands were delineated daywise in the SPECT/CT data. Kidney volumes of interest (VOIs) were drawn manually on the CT data. Lesions and submandibular glands were delineated using a 30% isocontour of the average within a spheric VOI of 12-mm diameter centered at the tissue maximum (26,27). To allow for a more robust quantification, only lesions with volumes larger than 5 cm3 were included. Only 10 submandibular glands could be investigated since segmentation was not possible for 2 patients because the field of view was too small. The parotid glands could not be evaluated, as they were not completely covered in the SPECT acquisitions. Mean activity concentrations and volumes were extracted. Absorbed doses were estimated using an in-house routine and mass-scaled organ and tumor S values as extracted from OLINDA/EXM version 2.0 (lesions: 2.33e−05 Gy/[MBq × s], 1 g; kidneys: 7.74e−08 Gy/[MBq × s], 310 g; salivary glands: 2.76e−07 Gy/[MBq × s], 85 g) (28).

Reference MTP Dosimetry

The TIA was first estimated for each compartment by fitting and integrating all available imaging time points using a monoexponential model and a biexponential model. For the latter, all possible realizations with up to 3 free parameters as proposed by Hardiansyah et al. were considered (29). All fit functions were evaluated by common goodness-of-fit criteria, that is, the coefficients of variation (CV) and the sum of squared errors (30,31). Finally, the following 2 functions were used to fit the reference MTP model:Embedded ImageEmbedded Image

A0 refers to A(t = 0), and Embedded Image and Embedded Image are the biologic and physical clearance rates, respectively. The population-based γ-parameter modulates the transition from the phase with biologic clearance to the phase without biologic clearance and was determined by the jackknife method. For the latter, the respective function is fitted to the data of all patients except the one currently being investigated. The CV refer to the 2 free parameters A0 (CVA) and λbio (CVλ).

STP Dosimetry

Three different STP approaches were evaluated with a single SPECT/CT acquisition at 24, 48, 72, or 168 h after injection: a monoexponential (STPmono) or a biexponential (STPbi) function with population-based biologic clearance rates; the method by Hänscheid et al., originally established for 177Lu-DOTATE/DOTATOC therapy (STPH) (12); and the method proposed by Jackson et al. (STPJ) (11).

The TIA for STPmono is given byEmbedded Image

Embedded Image and Embedded Image refer to imaging time point and the VOI activity measured for that time point, respectively. Two population-based parameters, Embedded Image and γ, were used for STPbi, with the TIA being given byEmbedded Image

For STPH, the TIA is estimated byEmbedded Image

Hänscheid et al. stated that if imaging is performed between Embedded Image and Embedded Image (Embedded Image is effective half-life), the error in the TIA is less than 10% (12). In this study, we investigated all available time points, assuming that time points that do not fulfil this criterion will automatically show a larger deviation from the reference. More information about the VOIs and time points Embedded Image for which the criterion Embedded Image < Embedded Image < Embedded Image was applied is given in Supplemental Table 2.

For STPJ, it is assumed thatEmbedded Imagewith ftissue being a scaling factor depending on time point and compartment. The factors were recalculated for our patient cohort according to the method described by Jackson et al. because of the different PSMA compound used in this study (Supplemental Table 2) (11).

Data Evaluation

The Wilcoxon signed-rank test was used to compare the dosimetry estimates and the goodness-of-fit parameters for the reference models monoexponential MTP (MTPmono) and biexponential MTP (MTPbi). Mean absolute deviations of STP methods from MTPmono and MTPbi were determined per compartment, whereupon STPmono was compared only with MTPmono and STPbi only with MTPbi. The best imaging time point or STP method was defined as the one with the lowest mean absolute deviation. The percentage of VOIs with a deviation of less than |10|% was used as a secondary criterion.

RESULTS

Table 3 shows the goodness-of-fit parameters for both the mono- and biexponential reference model, as well as the statistical evaluation. For the salivary glands, MTPbi seemed to be superior to MTPmono, as both the CV and the sum of squared errors were significantly lower (P < 0.05). Such was not the case for the kidneys. The average goodness-of-fit parameters would favor MTPbi but without statistical significance (P > 0.05). For the lesions, CV λbio significantly favored MTPmono (P < 0.05), whereas the sum of squared errors significantly favored MTPbi (P < 0.05). However, the monoexponential reference model yielded significantly lower absorbed doses than did the biexponential fit (Table 3). Although for both the kidneys and the lesions, no reference model was deemed to be superior, maximum absorbed dose deviations of −19% and −44% were found for kidneys and lesions, respectively (Table 3). As expected, CV λbio was found to be larger for lesions than for kidneys and salivary glands, indicating a larger pharmacokinetic variability for lesions. Average (±SD) effective half-lives were found to be 56.5 ± 18.8, 32.9 ± 5.9, and 22.5 ± 2.8 h for lesions, kidneys, and salivary glands, respectively. More information on the distribution of effective half-lives and some exemplary time–activity curves are shown in Supplemental Figures 3–5.

View this table:
  • View inline
  • View popup
TABLE 3.

Fit and Dosimetry Results for Reference Models

The deviations of all STP methods and imaging time points from the reference models are listed in Supplemental Tables 3 and 4.

Kidneys

For both reference models, 48 h after injection was found to be the optimum imaging time point (Figs. 1A and 1B). STPmono and STPH showed the smallest mean absolute deviations from the monoexponential reference model MTPmono, at 3% ± 4% and 4% ± 4%, respectively. Compared with the biexponential reference model MTPbi, STPbi and STPJ indicated the smallest mean absolute deviations of 4% ± 4% and 4% ± 5%, respectively, with a slight preference for STPbi since for 86% (vs. 71%) of VOIs the renal absorbed doses deviated less than 10% from the reference (Fig. 1D).

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

(A and B) Deviation of kidney STP dosimetry from MTP dosimetry using monoexponential (A) or biexponential (B) MTP reference models and for different imaging time points. (C and D) Percentage of VOIs with deviation less than |10|% using monoexponential (C) or biexponential (D) MTP reference models and for different imaging time points. Numbers above each bar indicate exact percentages. For better visualization, data for 168 h after injection are shown in Supplemental Figure 6 and Supplemental Tables 5 and 6. p.i. = after injection.

Salivary Glands

SPECT/CT imaging at 24 h after injection in combination with STPbi resulted in the lowest mean absolute dose deviation of 4% ± 4% (all VOIs within |10|%), when compared with the best-suited reference model, that is, MTPbi (Figs. 2B and 2D). At 48 h after injection, STPbi showed the best performance as well (mean absolute deviation of 10% ± 14%, with 70% of all VOIs within |10|%) (Figs. 2B and 2D).

FIGURE 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2.

(A and B) Deviations of salivary gland STP dosimetry from MTP dosimetry using monoexponential (A) and biexponential (B) reference models and different imaging time points. (C and D) Percentage of VOIs with deviation less than |10|% using monoexponential (C) and biexponential (D) reference models and different imaging time points. Numbers above each bar indicate exact percentages. For better visualization, data for 168 h after injection are shown in Supplemental Figure 6 and Supplemental Tables 5 and 6. p.i. = after injection.

Lesions

Larger deviations from the reference models were observed for lesions than for at-risk organs, with 48–72 h being the best-suited time point (Figs. 3A and 3B). Compared with MTPmono, STPmono and STPH—both with imaging at 72 h after injection—showed a similar performance (average deviation, 8% ± 9% and 7% ± 9%, respectively, with 73% and 70% of lesions deviating less than 10% from MTPmono) (Figs. 3A and 3C). Compared with MTPbi, similar average deviations for all 3 STP methods could be obtained (STPbi, 10% ± 13%; STPH, 16% ± 10%; and STPJ, 10% ± 10%) but with use of different optimum imaging time points (72 h for STPH and STPJ, 48 h for STPbi) (Figs. 3B and 3D).

FIGURE 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 3.

(A and B) Deviation of lesion STP dosimetry from MTP dosimetry using monoexponential (A) or biexponential (B) MTP reference models and for different imaging time points. (C and D) Percentage of VOIs with deviation less than |10|% using monoexponential (C) or biexponential (D) MTP reference models and for different imaging time points. Numbers above each bar indicate exact percentages. For better visualization, data for 168 h after injection are shown in Supplemental Figure 6 and Supplemental Tables 5 and 6. p.i. = after injection.

DISCUSSION

The aim of this study was to compare different STP approaches for 2 reference models and—apart from the bone marrow—the main compartments of interest during [177Lu]Lu-PSMA treatment, that is, lesions, kidneys, and salivary glands. Although MTPbi could be identified as the best-suited reference model for the salivary glands, no superiority of MTPbi or MTPmono could be established for kidney and lesion dosimetry using SPECT acquisitions at 24, 48, 72, and 168 h after injection. However, absorbed dose estimates were found to be significantly different for both reference models. A higher number of image acquisitions may help to reduce the ambiguity of the optimum reference model for lesion and kidney dosimetry. Yet, the number of image acquisitions available in a clinical setting is inherently limited. For example, although the late pharmacokinetics has a significant impact on dosimetry estimates (32), image acquisitions are usually terminated, at the latest, at around 7–9 d after injection for logistic reasons and because SPECT imaging at late time points is limited by a decreasing activity concentration. Although STP dosimetry is feasible, Figures 1, 2, 3A, and 3B highlight that the error of each STP method depends on the reference MTP protocol. Thus, an uncertainty in the reference MTP protocol automatically translates into the selection of the optimum STP method. Comparability of STP dosimetry from different studies requires careful consideration of the reference protocols that were used to define the STP methodology. In this sense, the popularity of STP dosimetry also strengthens the request for standardization of clinically feasible but reliable MTP protocols.

The optimum imaging time point for renal STP dosimetry is clearly 48 h for all STP methods and both reference models. As no superiority for MTPbi or MTPmono could be proven and, thus, the underlying pharmacokinetics is not well known, STPmono and STPbi should be avoided. Thus for kidney STP dosimetry, STPH is recommended over STPJ because the number of VOIs with a deviation of less than 10% is high for both MTPmono and MTPbi. Similarly, STPJ with imaging at 72 h can be recommended for lesion STP dosimetry. For the salivary glands, MTBbi could be identified as the optimum reference model, with imaging at 24 h after injection and STPbi being the best choice for STP dosimetry.

The definition of a specific STP methodology is further complicated by the fact that the optimal STP dosimetry for different compartments is usually associated with different optimum imaging time points. From a clinical perspective, STP approaches should be available with similar performance for lesions and organs at risk. However, considering the results in both Figure 1 and Figure 2, compared with Figure 3, a trade-off between the accuracy of dosimetry for lesions and at-risk organs is necessary. The optimum time point is also likely to depend on the question of whether the primary objective of dosimetry is safety or efficacy. It may be possible to merge STP dosimetry for lesions, kidneys, and salivary glands based on imaging at 48 h after therapy, although this will result in a lower level of accuracy for lesions (optimum, 72 h after injection) and salivary glands (optimum, 24 h after injection). For the salivary glands with MTPbi as the optimum reference protocol, STPbi is suggested for imaging at 48 h after injection. For lesion dosimetry, STPJ is recommended for imaging at 48 h after injection, as it shows a more balanced performance for MTPbi and MTPmono than does STPH.

The overall number of patients in this study was low. Especially, the used biexponential reference model applies a population-based shared parameter γ that should be reevaluated for a larger patient cohort. Further, this population-based parameter may vary over the course of subsequent therapy cycles, whereas only the first therapy cycle was investigated in this study. However, Hardiansyah et al. found a value of 0.963 ± 0.004 for the renal biokinetics of 13 [177Lu]Lu-PSMA-I&T patients (29), compared with a very similar value of 0.956 ± 0.007 (CV, 0.7%) for 14 kidneys and 7 patients in this study (0.8% deviation). In addition, the method proposed by Hänscheid et al. (12) was originally developed for monoexponential pharmacokinetics but was compared with a biexponential reference model in this study as well. However, the intention was to show the effect of an unknown ground truth model on STP methodology. For example, for the salivary glands, with clearly biexponential pharmacokinetics, STPH showed poor performance. Despite the smaller patient cohort, the optimum time points proposed in this study agreed well with previously published data (10,11,13,17,18). As data with a late SPECT scan at around 7 d after injection were available for only a selected number of patients undergoing their first treatment cycle in this study, no prior information on the compartment-specific effective half-life was available, limiting this study to population-based approaches only. Brosch-Lenz et al. investigated a prior-information approach based on the patient-specific effective half-life of the previous treatment cycle in comparison to the method proposed by Hänscheid et al. for kidney and lesion STP dosimetry and for [177Lu]Lu-PSMA-I&T therapy (10,12). The reference model was a monoexponential fit with SPECT/CT imaging at 24, 48, and 72 h after treatment. The method by Hänscheid et al. was slightly superior for the kidneys, whereas for lesion STP dosimetry the prior-information approach showed better performance, possibly because the lesion pharmacokinetics usually shows a larger interpatient and intrapatient variability.

Population-based approaches assume an average patient with average pharmacokinetics. It should be further investigated whether patient-specific factors, such as changes in tumor volume, kidney function, or any other patient-specific factors that deviate from the average patient, may guide the decision between MTP and STP dosimetry. Scheduling MTP dosimetry intermittently (e.g., alternating between MTP and STP dosimetry) may be a trade-off between clinical efficiency and accuracy. Further, in view of the observed outliers for different STP approaches, quality control is an important aspect of STP dosimetry. The use of mixed-linear-effects models, which consider each parameter as a combination of a mixed population-based effect and a random patient-specific effect, has already been shown to be promising for reducing outliers within STP dosimetry (19,24).

Current research also focuses on speeding the SPECT acquisition, a development that is lately being driven by the integration of artificial intelligence into molecular imaging (33–35). This should be considered as an opportunity to maintain MTP-based protocols, at least in centers that hospitalize patients or where multiple examinations are feasible on an outpatient basis.

CONCLUSION

STP dosimetry is becoming more popular because it allows for efficient integration of internal dosimetry into clinical routine. Usually, however, the considered reference MTP protocol already approximates the real but unknown clinical ground truth, and its error is in addition to the error of STP dosimetry itself. The intercomparison of different STP methods shows a different optimum time point and error depending on the compartment and the reference MTP protocol. According to our patient cohort, 48 h after injection may be regarded as a compromise for STP dosimetry for lesions and at-risk organs.

DISCLOSURE

Astrid Delker is partially funded by the Federal Ministry of Education and Research (funding number 02NUK065C). No other potential conflict of interest relevant to this article was reported.

KEY POINTS

QUESTION: Does the reference model impact findings on STP dosimetry for [177Lu]Lu-PSMA-I&T therapy?

PERTINENT FINDINGS: The error of each STP dosimetry method depends on compartment, time point, and reference MTP protocol. In our patient cohort, 48 h may be regarded as a compromise for dosimetry for lesions and healthy tissues.

IMPLICATIONS FOR PATIENT CARE: STP dosimetry for [177Lu]Lu-PSMA-I&T can be performed, but at the cost of some level of accuracy. Further efforts to standardize internal dosimetry are important to harmonize MTP and STP dosimetry among centers.

Footnotes

  • Published online Jun. 27, 2024.

  • © 2024 by the Society of Nuclear Medicine and Molecular Imaging.

Immediate Open Access: Creative Commons Attribution 4.0 International License (CC BY) allows users to share and adapt with attribution, excluding materials credited to previous publications. License: https://creativecommons.org/licenses/by/4.0/. Details: http://jnm.snmjournals.org/site/misc/permission.xhtml.

REFERENCES

  1. 1.↵
    1. Ljungberg M,
    2. Celler A,
    3. Konijnenberg MW,
    4. et al
    . MIRD pamphlet no. 26: joint EANM/MIRD guidelines for quantitative 177Lu SPECT applied for dosimetry of radiopharmaceutical therapy. J Nucl Med. 2016;57:151–162.
    OpenUrlAbstract/FREE Full Text
  2. 2.↵
    1. Sartor O,
    2. De Bono J,
    3. Chi KN,
    4. et al
    . Lutetium-177–PSMA-617 for metastatic castration-resistant prostate cancer. N Engl J Med. 2021;385:1091–1103.
    OpenUrlCrossRefPubMed
  3. 3.↵
    1. Strigari L,
    2. Konijnenberg M,
    3. Chiesa C,
    4. et al
    . The evidence base for the use of internal dosimetry in the clinical practice of molecular radiotherapy. Eur J Nucl Med Mol Imaging. 2014;41:1976–1988.
    OpenUrlCrossRefPubMed
  4. 4.↵
    1. Ilan E,
    2. Sandström M,
    3. Wassberg C,
    4. et al
    . Dose response of pancreatic neuroendocrine tumors treated with peptide receptor radionuclide therapy using 177Lu-DOTATATE. J Nucl Med. 2015;56:177–182.
    OpenUrlAbstract/FREE Full Text
  5. 5.↵
    1. Siegel JA,
    2. Thomas SR,
    3. Stubbs JB,
    4. et al
    . MIRD pamphlet no. 16: techniques for quantitative radiopharmaceutical biodistribution data acquisition and analysis for use in human radiation dose estimates. J Nucl Med. 1999;40:37S–61S.
    OpenUrlAbstract/FREE Full Text
  6. 6.
    1. Cremonesi M,
    2. Ferrari ME,
    3. Bodei L,
    4. et al
    . Correlation of dose with toxicity and tumour response to 90Y- and 177Lu-PRRT provides the basis for optimization through individualized treatment planning. Eur J Nucl Med Mol Imaging. 2018;45:2426–2441.
    OpenUrl
  7. 7.↵
    1. Rosar F,
    2. Schön N,
    3. Bohnenberger H,
    4. et al
    . Comparison of different methods for post-therapeutic dosimetry in [177Lu]Lu-PSMA-617 radioligand therapy. EJNMMI Phys. 2021;8:40.
    OpenUrl
  8. 8.↵
    1. Konijnenberg M,
    2. Herrmann K,
    3. Kobe C,
    4. et al
    . EANM position paper on article 56 of the Council Directive 2013/59/Euratom (basic safety standards) for nuclear medicine therapy. Eur J Nucl Med Mol Imaging. 2021;48:67–72.
    OpenUrl
  9. 9.↵
    1. Graves SA,
    2. Bageac A,
    3. Crowley JR,
    4. Merlino DAM
    . Reimbursement approaches for radiopharmaceutical dosimetry: current status and future opportunities. J Nucl Med. 2021;62(suppl 3):48S–59S.
    OpenUrlAbstract/FREE Full Text
  10. 10.↵
    1. Brosch-Lenz J,
    2. Delker A,
    3. Völter F,
    4. et al
    . Toward single-time-point image-based dosimetry of 177Lu-PSMA-617 therapy. J Nucl Med. 2023;64:767–774.
    OpenUrlAbstract/FREE Full Text
  11. 11.↵
    1. Jackson PA,
    2. Hofman MS,
    3. Hicks RJ,
    4. Scalzo M,
    5. Violet J
    . Radiation dosimetry in 177Lu-PSMA-617 therapy using a single posttreatment SPECT/CT scan: a novel methodology to generate time- and tissue-specific dose factors. J Nucl Med. 2020;61:1030–1036.
    OpenUrlAbstract/FREE Full Text
  12. 12.↵
    1. Hänscheid H,
    2. Lapa C,
    3. Buck AK,
    4. Lassmann M,
    5. Werner RA
    . Dose mapping after endoradiotherapy with 177Lu-DOTATATE/DOTATOC by a single measurement after 4 days. J Nucl Med. 2018;59:75–81.
    OpenUrlAbstract/FREE Full Text
  13. 13.↵
    1. Kurth J,
    2. Heuschkel M,
    3. Tonn A,
    4. et al
    . Streamlined schemes for dosimetry of 177Lu-labeled PSMA targeting radioligands in therapy of prostate cancer. Cancers (Basel). 2021;13:3884.
    OpenUrl
  14. 14.
    1. Willowson KP,
    2. Eslick E,
    3. Ryu H,
    4. Poon A,
    5. Bernard EJ,
    6. Bailey DL
    . Feasibility and accuracy of single time point imaging for renal dosimetry following 177Lu-DOTATATE (‘Lutate’) therapy. EJNMMI Phys. 2018;5:33.
    OpenUrl
  15. 15.
    1. Madsen MT,
    2. Menda Y,
    3. O’Dorisio TM,
    4. O’Dorisio MS
    . Technical note: single time point dose estimate for exponential clearance. Med Phys. 2018;45:2318–2324.
    OpenUrl
  16. 16.
    1. Mix M,
    2. Renaud T,
    3. Kind F,
    4. et al
    . Kidney doses in 177Lu-based radioligand therapy in prostate cancer: is dose estimation based on reduced dosimetry measurements feasible? J Nucl Med. 2022;63:253–258.
    OpenUrlAbstract/FREE Full Text
  17. 17.↵
    1. Peters SMB,
    2. Mink MCT,
    3. Privé BM,
    4. et al
    . Optimization of the radiation dosimetry protocol in lutetium-177-PSMA therapy: toward clinical implementation. EJNMMI Res. 2023;13:6.
    OpenUrl
  18. 18.↵
    1. Rinscheid A,
    2. Kletting P,
    3. Eiber M,
    4. Beer AJ,
    5. Glatting G
    . Influence of sampling schedules on [1177Lu]Lu-PSMA dosimetry. EJNMMI Phys. 2020;7:41.
    OpenUrl
  19. 19.↵
    1. Hardiansyah D,
    2. Riana A,
    3. Beer AJ,
    4. Glatting G
    . Single-time-point dosimetry using model selection and nonlinear mixed-effects modelling: a proof of concept. EJNMMI Phys. 2023;10:12.
    OpenUrl
  20. 20.
    1. Hou X,
    2. Brosch J,
    3. Uribe C,
    4. et al
    . Feasibility of single-time-point dosimetry for radiopharmaceutical therapies. J Nucl Med. 2021;62:1006–1011.
    OpenUrlAbstract/FREE Full Text
  21. 21.
    1. Peterson AB,
    2. Mirando DM,
    3. Dewaraja YK
    . Accuracy and uncertainty analysis of reduced time point imaging effect on time-integrated activity for 177Lu-DOTATATE PRRT in patients and clinically realistic simulations. EJNMMI Res. 2023;13:57.
    OpenUrl
  22. 22.
    1. Chicheportiche A,
    2. Sason M,
    3. Zidan M,
    4. et al
    . Impact of single-time-point estimates of 177Lu-PRRT absorbed doses on patient management: validation of a trained multiple-linear-regression model in 159 patients and 477 therapy cycles. J Nucl Med. 2023;64:1610–1616.
    OpenUrlAbstract/FREE Full Text
  23. 23.
    1. Pirozzi Palmese V,
    2. D’Ambrosio L,
    3. Di Gennaro F,
    4. et al
    . A comparison of simplified protocols of personalized dosimetry in NEN patients treated by radioligand therapy (RLT) with [177Lu]Lu-DOTATATE to favor its use in clinical practice. Eur J Nucl Med Mol Imaging. 2023;50:1753–1764.
    OpenUrl
  24. 24.↵
    1. Devasia TP,
    2. Dewaraja YK,
    3. Frey KA,
    4. Wong KK,
    5. Schipper MJ
    . A novel time-activity information-sharing approach using nonlinear mixed models for patient-specific dosimetry with reduced imaging time points: application in SPECT/CT after 177Lu-DOTATATE. J Nucl Med. 2021;62:1118–1125.
    OpenUrl
  25. 25.↵
    1. Chicheportiche A,
    2. Sason M,
    3. Godefroy J,
    4. et al
    . Simple model for estimation of absorbed dose by organs and tumors after PRRT from a single SPECT/CT study. EJNMMI Phys. 2021;8:63.
    OpenUrl
  26. 26.↵
    1. Resch S,
    2. Takayama Fouladgar S,
    3. Zacherl M,
    4. et al
    . Investigation of image-based lesion and kidney dosimetry protocols for 177Lu-PSMA-I&T therapy with and without a late SPECT/CT acquisition. EJNMMI Phys. 2023;10:11.
    OpenUrl
  27. 27.↵
    1. Frings V,
    2. van Velden FH,
    3. Velasquez LM,
    4. et al
    . Repeatability of metabolically active tumor volume measurements with FDG PET/CT in advanced gastrointestinal malignancies: a multicenter study. Radiology. 2014;273:539–548.
    OpenUrlCrossRefPubMed
  28. 28.↵
    1. Stabin MG,
    2. Sparks RB,
    3. Crowe E
    . OLINDA/EXM: the second-generation personal computer software for internal dose assessment in nuclear medicine. J Nucl Med. 2005;46:1023–1027.
    OpenUrlAbstract/FREE Full Text
  29. 29.↵
    1. Hardiansyah D,
    2. Riana A,
    3. Kletting P,
    4. et al
    . A population-based method to determine the time-integrated activity in molecular radiotherapy. EJNMMI Phys. 2021;8:82.
    OpenUrl
  30. 30.↵
    1. Kletting P,
    2. Schimmel S,
    3. Kestler HA,
    4. et al
    . Molecular radiotherapy: the NUKFIT software for calculating the time-integrated activity coefficient. Med Phys. 2013;40:102504.
    OpenUrlCrossRefPubMed
  31. 31.↵
    1. Bonate LP
    . Pharmacokinetic-Pharmacodynamic Modeling and Simulation. 2nd ed. Springer; 2011:14–29.
  32. 32.↵
    1. Delker A,
    2. Ilhan H,
    3. Zach C,
    4. et al
    . The influence of early measurements onto the estimated kidney dose in [177Lu][DOTA0,Tyr3]octreotate peptide receptor radiotherapy of neuroendocrine tumors. Mol Imaging Biol. 2015;17:726–734.
    OpenUrl
  33. 33.↵
    1. Rydén T,
    2. Van Essen M,
    3. Marin I,
    4. Svensson J,
    5. Bernhardt P
    . Deep-learning generation of synthetic intermediate projections improves 177Lu SPECT images reconstructed with sparsely acquired projections. J Nucl Med. 2021;62:528–535.
    OpenUrlAbstract/FREE Full Text
  34. 34.
    1. Sohlberg A,
    2. Kangasmaa T,
    3. Constable C,
    4. Tikkakoski A
    . Comparison of deep learning-based denoising methods in cardiac SPECT. EJNMMI Phys. 2023;10:9.
    OpenUrl
  35. 35.↵
    1. Liu J,
    2. Yang Y,
    3. Wernick MN,
    4. Pretorius PH,
    5. King MA
    . Deep learning with noise-to-noise training for denoising in SPECT myocardial perfusion imaging. Med Phys. 2021;48:156–168.
    OpenUrl
  • Received for publication October 17, 2023.
  • Accepted for publication April 22, 2024.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 65 (8)
Journal of Nuclear Medicine
Vol. 65, Issue 8
August 1, 2024
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
  • Complete Issue (PDF)
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Impact of the Reference Multiple-Time-Point Dosimetry Protocol on the Validity of Single-Time-Point Dosimetry for [177Lu]Lu-PSMA-I&T Therapy
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Impact of the Reference Multiple-Time-Point Dosimetry Protocol on the Validity of Single-Time-Point Dosimetry for [177Lu]Lu-PSMA-I&T Therapy
Sandra Resch, Sibylle I. Ziegler, Gabriel Sheikh, Lena M. Unterrainer, Mathias J. Zacherl, Peter Bartenstein, Guido Böning, Julia Brosch-Lenz, Astrid Delker
Journal of Nuclear Medicine Aug 2024, 65 (8) 1272-1278; DOI: 10.2967/jnumed.123.266871

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Impact of the Reference Multiple-Time-Point Dosimetry Protocol on the Validity of Single-Time-Point Dosimetry for [177Lu]Lu-PSMA-I&T Therapy
Sandra Resch, Sibylle I. Ziegler, Gabriel Sheikh, Lena M. Unterrainer, Mathias J. Zacherl, Peter Bartenstein, Guido Böning, Julia Brosch-Lenz, Astrid Delker
Journal of Nuclear Medicine Aug 2024, 65 (8) 1272-1278; DOI: 10.2967/jnumed.123.266871
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Visual Abstract
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF

Related Articles

  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • First-in-Human Study of 18F-Labeled PET Tracer for Glutamate AMPA Receptor [18F]K-40: A Derivative of [11C]K-2
  • Detection of HER2-Low Lesions Using HER2-Targeted PET Imaging in Patients with Metastatic Breast Cancer: A Paired HER2 PET and Tumor Biopsy Analysis
  • [11C]Carfentanil PET Whole-Body Imaging of μ-Opioid Receptors: A First in-Human Study
Show more Clinical Investigation

Similar Articles

Keywords

  • PSMA
  • 177Lu
  • dosimetry
  • single time point
SNMMI

© 2025 SNMMI

Powered by HighWire