Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
LetterLetters to the Editor

64Cu-DOTA Enables Late PET Imaging and Leak Detection in the Cerebrospinal Fluid Space

Robert Drescher, Julia Greiser, Sebastian Gröber, Thomas Weisheit and Martin Freesmeyer
Journal of Nuclear Medicine May 2024, 65 (5) 822; DOI: https://doi.org/10.2967/jnumed.123.267329
Robert Drescher
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Julia Greiser
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Sebastian Gröber
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Thomas Weisheit
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Martin Freesmeyer
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
  • PDF
Loading

TO THE EDITOR: Recently, PET of the cerebrospinal fluid (CSF) space with [68Ga]Ga-DOTA has been proposed as a fast and convenient approach for verification of spinal CSF leaks (1). PET-based radiocisternography with [68Ga]Ga-ethylenediaminetetraacetic acid, [55Co]Co-diethylenetriaminepentaacetic acid (DTPA), and [64Cu]Cu-DTPA was reported as early as 1982 (2,3). We would like to highlight the existence of another tracer, [64Cu]Cu-DOTA, for CSF space imaging.

The advantage of 68Ga-based radiotracers is the wide availability of 68Ga and a generally convenient and fast production via metal chelation. The disadvantage is the short half-life of 68 min, impairing imaging of slow or intermittent processes. Therefore, the radiopharmaceutical production of [64Cu]Cu-DOTA, with a half-life of 12.7 h, has been established in our clinic in compliance with standards of good manufacturing practice (4,5).

Since 2018, 5 patients with intracranial hypotension, in whom CT or MRI as well as radionuclide cisternography with [111In]In-DTPA were inconclusive, underwent PET/CT of the CSF space in the Clinic of Nuclear Medicine, Jena University Hospital, Germany. No immediate or late complications occurred after lumbar intrathecal [64Cu]Cu-DOTA injection. In 3 cases, a spinal CSF leak was identified.

Because of the shorter positron range of 64Cu than of 68Ga, the PET image quality of [64Cu]Cu-DOTA can be expected to be superior to that of [68Ga]Ga-DOTA, enabling location and identification of small CSF leaks (6). This high image quality is maintained during delayed imaging performed 20 h after injection and may be particularly helpful to locate craniocervical CSF leaks after surgical procedures (case example available in (7)).

Intrathecal injection of CT or MRI contrast agents has been associated with a high probability of adverse events (8,9). Also, [111In]In-DTPA injections have caused neurologic reactions due to ion sequestration in the CSF caused by excess chelator (10,11). The CSF is a sensible system, exhibiting few proteins and limited buffering capability. Formulations administered into the CSF space should contain ingredients in the smallest possible quantities. The amount of precursor in [64Cu]Cu-DOTA is lower by a factor of 1,000 than that in CT or MRI contrasts agent, which makes [64Cu]Cu-DOTA safer for intrathecal injections (5). pH, osmolality, and a low-salt concentration of [64Cu]Cu-DOTA are optimally adjusted to the CSF fluid. In contrast, the [68Ga]Ga-DOTA preparation as reported by Evangelou et al. (1) may contain elevated concentrations of NaCl and sodium acetate due to the acidic labeling conditions of 68Ga (3). Furthermore, [64Cu]Cu-DOTA production can be performed up to 24 h before administrations, thus granting a longer time frame for application than is possible with [68Ga]Ga-DOTA.

With regard to the cost and yet limited availability of 64Cu, PET cisternography with [64Cu]Cu-DOTA is seen as a reserve, but important, method in difficult cases with intracranial hypertension. Because of the long half-life of the tracer and the high-resolution capabilities of PET/CT, and 64Cu PET/CT in particular, localization of slow-flow CSF leaks in patients with intracranial hypotension can be enabled. The next research step will be dosimetric evaluation of the new tracer.

Robert Drescher, Julia Greiser, Sebastian Gröber, Thomas Weisheit, Martin Freesmeyer*

*Jena University Hospital, Jena, Germany

E-mail: martin.freesmeyer{at}med.uni-jena.de

Footnotes

  • Published online Mar. 14, 2024.

  • © 2024 by the Society of Nuclear Medicine and Molecular Imaging.

REFERENCES

  1. 1.↵
    1. Evangelou P,
    2. Omrane MA,
    3. Thurow J,
    4. et al
    . 68Ga-DOTA PET for diagnosis of spinal cerebrospinal fluid leaks. J Nucl Med. 2023;64:430–436.
    OpenUrlAbstract/FREE Full Text
  2. 2.↵
    1. Bergstrand G,
    2. Bergstrom M,
    3. Eriksson L,
    4. Edner G,
    5. Widen L
    . Positron emission tomography with 68Ga-EDTA in the diagnosis and localization of CSF fistulas. J Comput Assist Tomogr. 1982;6:320–324.
    OpenUrlCrossRefPubMed
  3. 3.↵
    1. Mazière B,
    2. Stulzaft O,
    3. Verret JM,
    4. Comar D,
    5. Syrota A
    . [55Co]- and [64Cu]DTPA: new radiopharmaceuticals for quantitative tomocisternography. Int J Appl Radiat Isot. 1983;34:595–601.
    OpenUrlPubMed
  4. 4.↵
    1. Freesmeyer M,
    2. Schwab M,
    3. Besteher B,
    4. Grober S,
    5. Waschke A,
    6. Drescher R
    . High-resolution PET cisternography with 64Cu-DOTA for CSF leak detection. Clin Nucl Med. 2019;44:735–737.
    OpenUrl
  5. 5.↵
    1. Greiser J,
    2. Groeber S,
    3. Weisheit T,
    4. et al
    . Radionuclide cisternography with [64Cu]Cu-DOTA. Pharmaceuticals (Basel). 2023;16:1269.
    OpenUrl
  6. 6.↵
    1. Braune A,
    2. Oehme L,
    3. Freudenberg R,
    4. et al
    . Comparison of image quality and spatial resolution between 18F, 68Ga, and 64Cu phantom measurements using a digital Biograph Vision PET/CT. EJNMMI Phys. 2022;9:58.
    OpenUrl
  7. 7.↵
    PET cisternography with Cu-64-DOTA. Research Gate website. http://dx.doi.org/10.13140/RG.2.2.12279.80809. Published January 2024. Accessed February 28, 2024.
  8. 8.↵
    1. Reeves C,
    2. Galang E,
    3. Padalia R,
    4. Tran N,
    5. Padalia D
    . Intrathecal injection of gadobutrol: a tale of caution. J Pain Palliat Care Pharmacother. 2017;31:139–143.
    OpenUrlCrossRefPubMed
  9. 9.↵
    OMNIPAQUE-iohexol injection, solution. Product information. GE Healthcare Inc.; 2010.
  10. 10.↵
    1. Verbruggen AM,
    2. De Roo M,
    3. Klopper J
    . Technetium-99m diethylene triamine pentaacetic acid for intrathecal administration: are we playing with fire? Eur J Nucl Med. 1994;21:261–263.
    OpenUrlPubMed
  11. 11.↵
    1. Ponto JA
    . Special safety considerations in preparation of technetium Tc-99m DTPA for cerebrospinal fluid-related imaging procedures. J Am Pharm Assoc. 2008;48:413–416.
    OpenUrl
  • Received for publication January 30, 2024.
  • Revision received February 13, 2024.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 65 (5)
Journal of Nuclear Medicine
Vol. 65, Issue 5
May 1, 2024
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
  • Complete Issue (PDF)
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
64Cu-DOTA Enables Late PET Imaging and Leak Detection in the Cerebrospinal Fluid Space
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
64Cu-DOTA Enables Late PET Imaging and Leak Detection in the Cerebrospinal Fluid Space
Robert Drescher, Julia Greiser, Sebastian Gröber, Thomas Weisheit, Martin Freesmeyer
Journal of Nuclear Medicine May 2024, 65 (5) 822; DOI: 10.2967/jnumed.123.267329

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
64Cu-DOTA Enables Late PET Imaging and Leak Detection in the Cerebrospinal Fluid Space
Robert Drescher, Julia Greiser, Sebastian Gröber, Thomas Weisheit, Martin Freesmeyer
Journal of Nuclear Medicine May 2024, 65 (5) 822; DOI: 10.2967/jnumed.123.267329
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Footnotes
    • REFERENCES
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Business Model Beats Science and Logic: Dosimetry and Paucity of Its Use
  • Determining PSMA-617 Mass and Molar Activity in Pluvicto Doses
  • The Value of Functional PET in Quantifying Neurotransmitter Dynamics
Show more Letters to the Editor

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire